OMRON D40A-2 Safety Door Switch Instruction Manual

September 24, 2024
Omron

OMRON D40A-2 Safety Door Switch

Specifications

  • Model: D40A-2
  • Type: Safety Door Switch
  • Compliance: EU Directives and UK Legislation
  • Safety Standards: ISO/EN ISO 13849-1, IEC/EN 61508, IEC/EN 60947-5-3, EN 55011, ISO/EN ISO 14119, UL 508, CAN/CSA C22.2 No. 14

Product Usage Instructions

Safety Precautions
WARNING: Always follow safety precautions to avoid injury or damage.

  • Use only appropriate components complying with relevant safety standards.
  • Ensure conformity to the required performance level and category as an entire system.
  • Install the switch and actuator at an appropriate distance to prevent access to hazards.
  • Inspect the product daily and every 6 months to prevent system malfunctions.

Installation
When installing the D40A-2 Safety Door Switch:

  • Use the dedicated actuator D40A-A2.
  • Follow ISO/EN ISO 14119 guidelines for installation wit operator safety in mind.
  • Avoid placing the actuator or magnet close to the switch when the door is opened.

Maintenance

Regularly inspect the product

  • Inspect daily for any visible issues or malfunctions.
  • Perform a thorough inspection every 6 months to ensure proper functioning.

Frequently Asked Questions (FAQ):
Q: Can I use components other than the dedicated actuator D40A-A2 with the Safety Door Switch?
A: It is recommended to use only the dedicated actuator D40A-A2 to ensure proper functionality and safety.

Model D40A-2
Safety Door Switch
The D40A-2 safety door switch provides a safety-related interruption at a specified proximity position of its actuator through a safety controller.

INSTRUCTION MANUAL

Thank you for purchasing D40A-2 Safety Door Switch. Please read and understand this manual before using the products. Keep this manual ready to use whenever needed. Only qualified person trained in professional electrical technique should handle D40A-2. Please consult your OMRON representative if you have any questions or comments. Make sure that information written in this document are delivered to the final user of the product.
© OMRON Corporation 2024 All Rights Reserved.

Instructions in the EU languages and a signed EU Declaration of Conformity are available on our website at http://www.industrial.omron.eu/safety

Declaration of Conformity

  • OMRON declares that D40A-2 is in conformity with the
  • requirements of the following EU Directives and UK Legislation:
  • EU: Machinery Directive 2006/42/EC, EMC Directive 2014/30/EU,
  • RoHS Directive 2011/65/EU
  • UK: 2008 No. 1597 Machinery (Safety), 2016 No. 1091 EMC,
  • 2012 No. 3032 RoHS

Safety Standards

  • D40A-2 is designed and manufactured in accordance with the
  • following standards:
  • ISO/EN ISO 13849-1: Cat. 4 PL e*
  • IEC/EN 61508 SIL3*
  • IEC/EN 60947-5-3 PDDB*
  • EN 55011, ISO/EN ISO 14119 (Low level coded)
  • UL 508, CAN/CSA C22.2 No. 14
    • D40A-2 complies with these standards when connected to
  • the following OMRON Safety Controllers:
  • Non-Contact Door Switch Controller: G9SX-NS Series
  • Safety Controller: G9SP Series or NX Series Safety Control Unit

Safety Precautions

WARNING
Indicates a potentially hazardous situation which, if not avoided, will result in minor or moderate injury, or may result in serious injury or death.
Additionally there may be significant property damage.

Alert Statements

WARNING

  • Use only appropriate components or devices complying with relevant safety standards corresponding to the required performance level and category. Conformity to requirements of the performance level category must be determined as an entire system. It is recommended to consult a = certification body regarding assessment of conformity to the required safety level.

  • Serious injury may occur in an accident. Make sure to use the dedicated actuator D40A-A2, and install the switch and actuator at an appropriate distance so that they do not create a gap that provides access to the hazard.

  • Serious injury may occur in an accident. When complying with safety standards, install the product in accordance with ISO/EN ISO 14119 with due consideration of the risk of the operator deactivating it.

  • Auxiliary output is NOT a safety output. Do not use the Auxiliary output individually for any safety function. Such incorrect use causes loss of the safety function of the product and its relevant systems.

  • Serious injury may possibly occur in an accident. Do not put the actuator or magnet close to the switch when the door is opened.

  • Be sure to inspect the product daily and every 6 months. Otherwise, serious injury may possibly occur due to the system malfunction.

Precautions for Correct Use

  1. The contents of Precautions for Safe Use: Paragraph 16 Series Connection, Section 5. Connection Example, and Troubleshooting in this instruction manual are based on the assumption that the product will be used in combination with the G9SX-NS series. Refer to the D40A-2 data sheet (Cat. No. F133) for use in combination with other OMRON safety controllers.

  2. Do not drop the product to the ground or expose to vibration or mechanical shocks out of the rated values. Doing so may damage the product and cause failure.

  3. Do not store or installation the product in the following places. Doing so may result in product failure, or incorrect operation.

  4. Places subject to direct sunlight

  5. Operation in the range exceeding -25°C to 70°C Storage at temperatures exceeding -25°C to 75°C

  6. Operation in the range of relative humidity exceeding 25% to 85% Storage at relative humidity exceeding 25% to 95% Places subject to condensation due to sudden temperature changes

  7. Places subject to corrosive or flammable gases

  8. Places subject to vibration or mechanical shocks exceeding the rated values to the product

  9. Operation in locations subject to exposure to oil, or chemicals Storage in locations subject to exposure to water, oil, or chemicals

  10. Places subject to dust, salt, or iron particles

  11. Places subject to iron cuttings or particles, etc. are directly exposed

  12. Do not mount the switch and actuator on magnetic materials, otherwise it may affect the operating distance. Refer to the chart below for the estimated influence.
    Distance from magnetic materials| Operating distance
    ---|---
    Less than 5 mm| Operates approximately 90% of the original value
    5 mm Min.| Operation is not affected

  13. (5) Wiring

  14. Use the following wire sizes for wiring.
    -Stranded wire: 0.2 to 2.5 mm2 AWG24 to AWG12
    -Solid wire: 0.2 to 2.5 mm2 AWG24 to AWG12

  15.  When not using the auxiliary output, cut and insulate the unused wires to prevent contact with other terminals.

  16.  If laying an additional cable of 20 m or longer, bundle the white, black, brown and blue lines together.

  17. Do not use the product as a stopper. Keep the distance
    between switch and actuator at least 1 mm.

  18. Handling the Cables:

  19. When bending cables for wiring, the bending radius shall be times or more than the cable outer diameter.

  20. Do not apply a tensile strength of 50 N or greater to the cables.

  21. When two or more Switches are mounted side-by-side, they must be no closer than the following distance.

  22. Do not use the product at an altitude of 2,000 m or higher.

  23.  The degree of protection does not guarantee performance in environments with continuous water exposure. Do not use the product in water. Doing so may lead to water entered into the product.
    Conditions for the degree of protection
    Temperature range: 15 to 35°C, Humidity: 25 to 75%,
    Atmospheric pressure: 86 to 106 kpa

  24. Never disassemble, repair, or modify the product. Doing so may
    cause loss of the safety function.

  25. Do not use the product in magnetic fields greater than 1.0 mT.
    The product may not function properly.

  26.  Insert the surge absorber as follows:

    • D40A-2C: Between the blue wire and the white, black, brown, and yellow wires
    • D40A-2D: Between the blue wire and the white, black, and brown wires, and between the yellow wire and the gray wire The recommended surge absorber specifications are as follows:
    • Peak pulse power: 600 W (10/1000 μs) or more (Per IEC 61000-4-5 (surge immunity))
    • Breakdown voltage: 30 to 35 V
  27. Do not allow the product to come into contact with oil or solvents.
    The oil or solvents can cause the markings on the product to become illegible and lead to deterioration of certain parts.

  28. In a residential environment, this product may cause radio interference, in which case the user may be required to take adequate measures.

  29. Use the product under the following conditions for in-series connection.

  30. Connect up to 30 units of the product.

  31. Wire the product in series according to the following conditions for the total wiring length. The supply voltage to the product may decrease due to voltage drop depending on the cables or the wiring configuration.=   Make sure the power supply voltage for the product is withinthe rated range
    30 or less the D40A-1  series, D40A-2  series or D40Z connected.

Auxiliary output load
The auxiliary output load current of the D40A- must be met the following conditions.

When using G9SX-NS202

Possible for up to 15 Units| 50 mA max.
16 to 20 Units| 30 mA max.
21 to 30 Units| 20 mA max.
When using G9SX-NSA222

Possible for up to 30 Units| 50 mA max.

Note. The wiring length between the products must be 100 m max.
The D40A-2 series connected in series can be used together with the D40A series (D40A-1C) or the D40Z series. However, the D40A series (D40A-1C) and the D40Z series cannot be used together.

Detection Ranges

Note. Refer to the D40A-2 data sheet (Cat No. F133) for details on the engineering data examples.

Switch and actuator operation

  •  Switch and Actuator Mounting Directions

  • Switch and Actuator Operating Directions

Indicators

LED color Status
Red Sensor does NOT detect actuator
Yellow Sensor detect actuator

Internal connection

Ratings and Specifications

  • Ratings
Item D40A-£2££
Supply voltage 24 VDC +10%/-15% (class 2 or LVLC)
Rated power consumption 0.6 W max. (See note 1.)
Auxiliary output D40A-2C 24 VDC, 50 mA

(PNP transistors output) D40A-2D: 24 VDC, 20 mA

(Photocoupler output)

  • Specifications and Performance

  • Note 1. Power consumption of loads is not included.

  • Note 2. Operating distance means the distance of sensing surfaces between switch and actuator.

  • Note 3. The D40A-S2C015-F and D40A-2C015-F connector types are not supported.

Connection Example

  • Multiple switch connection
    Maximum 30 switches can be connected in series.

  • Single switch connection
    (See note.)

Wiring

Signal Name Wiring color Pin number Description of operation
Safety door switch power input + Brown 1

Connect to D3 terminal and D4 terminal on G9SX-NS.

–| Blue| 3
Safety door switch signal input| White| 2| Input designated signal from G9SX- NS

To set safety door switch output in ON state, safety door switch input must be in ON state.

Safety door switch output| Black| 4| Output status depends on actuator status and safety door switch input state.
Auxiliary output| Yellow| 5| Output when sensor detect actuator.
Gray| —

Note. When connecting a XS2F series connector with cable to a connector type, the color of the auxiliary output cable is gray.

Dimensions (Unit: mm)

D40A-2C015-F

D40A-A2

Troubleshooting

Indicator (See note.)| Expected causes of the faults| Checking points and measures to take
---|---|---
D40A-2| G9SX-NS
Light off| NS Light off| Failures involving the wiring of power supply input| Make sure the brown and blue power input wires of the

D40A-2£ are properly connected to the D3 and D4 terminals of the G9SX-NS , respectively.

Failures of the parts of the circuits of D40A-2| Replace with a new D40A-2
Red Light on|

NS Light off

| Sensor does NOT detect actuator| Make sure to use the correct actuator D40A-A2, and install the product in the correct mounting direction.
Magnetic forces other than the D40A-A2 actuator were detected| Keep the D40A-2 actuator away from the magnetic force generating object such as a magnet catch.
Failures of the parts of the circuits of D40A-2| Replace with a new D40A-2

Yellow Light on

|

NS Light off or NS Blink

| Failures involving the wiring of D40A- input| Make sure the white input signal wire of the D40A-2 is correctly wired.
Failures involving the wiring of D40A-2 outputs| Make sure the black output signal wire of the D40A-2 is correctly wired.
Failures of the parts of the circuits of D40A-2| Replace the switch or controller.

Note. When the switch and actuator are within the ON area.
Some of the main causes are listed above. Refer to the D40A-2 data sheet (Cat No. F133) for others.

Performance Level and Category

The D40A-2 together with OMRON safety controllers listed in the Safety Standards can construct the condition conforming to PL e and Category 4 required by EN ISO 13849-1 European standard. Refer to the following link to the reliability data for safety of machinery:
https://www.ia.omron.com/support/sistemalibrary/index.html
However, this system configuration is based on the example circuit provided by OMRON and may not apply to your system. The performance level of the D40A-2 is determined by the entire safety control system, so make sure that it applies to your system.
The D40A-2 device is not provided UL certification for any functional safety rating or aspects.

Suitability for Use

Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer’s application, product or system.
Buyer shall take application responsibility in all cases.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.

Inspection & Maintenance

  • Daily inspection
    Check every guard door to see that machine stops when guard door is opened.

  • Periodic inspection
    In addition to daily inspection, be sure to conduct inspections every 6 months.

  1. Isolate all power.

  2.  Check the switch and actuator for proper alignment.

  3. Check terminals for proper connections.

  4. Check wiring for signs of damage.

  5. Before resuming normal machine operation, check every guard door to see that machine stops when the guard door is opened.
    Based on ISO 14119, if the system requires a hands-on functional test, also consider the following inspection frequencies:

    • SIL3/ PL e at least once a month
    • SIL2/ PL d at least once a year

OMRON Corporation (Manufacturer)
Contact: www.ia.omron.com

Regional Headquarters

  • Shiokoji Horikawa, Shimogyo-ku, Kyoto, 600-8530 JAPAN
  • OMRON EUROPE B.V. (Importer in EU)
  • Wegalaan 67-69, 2132 JD Hoofddorp
  • The Netherlands
  • Tel: (31)2356-81-300/Fax: (31)2356-81-388

OMRON ELECTRONICS LLC

OMRON ASIA PACIFIC PTE. LTD.

  • 438B Alexandra Road, #08-01/02
  • Alexandra Technopark,
  • Singapore 119968
  • Tel: (65) 6835-3011/Fax: (65) 6835-3011

OMRON (CHINA) CO., LTD.

  • Room 2211, Bank of China Tower,
  • 200 Yin Cheng Zhong Road,
  • PuDong New Area, Shanghai, 200120, China
  • Tel: (86) 21-6023-0333/Fax: (86) 21-5037-2388

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals