MEAN WELL NDR-480 Series 480W Single Output Industrial DIN RAIL User Guide
- June 3, 2024
- MEAN WELL
Table of Contents
NDR-480 Series 480W Single Output Industrial DIN RAIL
User Guide
NDR-480 Series 480W Single Output Industrial DIN RAIL
https://www.meanwell.com/Upload/PDF/NDR%20DIN%20rail.pdf
80W Single Output Industrial DIN RAIL
Features
- Universal AC input / Full range
- Built-in active PFC function
- Protections: Short circuit / Overload / Over voltage / Over temperature
- Cooling by free air convection
- Can be installed on DIN rail TS-35/7.5 or 15
- UL 508 (industrial control equipment) approved
- BS EN/EN61000-6-2(BS EN/EN50082-2) industrial immunity level
- 100% full load burn-in test
- 3 years warranty
Applications
- Industrial control system
- Factory automation
- Electro-mechanical apparatus
GTIN CODE
MW Search: https://www.meanwell.com/serviceGTlN.aspx
Description
NDR-480 is one economical slim 480W Din rail power supply series, adapt to be
installed on TS-35/7.5 or TS-35/15 mounting rails. The body is designed 85.5mm
in width, which allows space saving inside the cabinets. The entire series
adopts the full range AC input from 90VAC to 264VAC and conforms to BS
EN/EN61000-3-2, the norm the European Union regulates for harmonic current.
NDR-480 is designed with metal housing that enhances the unit’s power
dissipation. With working efficiency up to 92.5%, the entire series can
operate at the ambient temperature between -20t and 70t under air convection.
It is equipped with constant current mode for over-load protection, fitting
various inductive or capacitive applications. The complete protection
functions and relevant certificates for industrial control apparatus (UL508,
TUV BS EN/EN62368-1, and etc.) make NDR-480 a very competitive power supply
solution for industrial applications.
Model Encoding
SPECIFICATION
MODEL | NDR-480-24 | NDR-480-48 |
---|---|---|
OUTPUT | DC VOLTAGE | 24V |
RATED CURRENT | 20A | 10A |
CURRENT RANGE | 0 – 20A | 0 – 10A |
RATED POWER | 480W | 480W |
RIPPLE & NOISE (max.) Note/ | 150mVp-p | 150mVp-p |
VOLTAGE ADJ. RANGE | 24 – 28V | 48 – 55V |
VOLTAGE TOLERANCE tiots.3 | ±1.0% | ±1.0% |
LINE REGULATION | ± 0.5% | ± 0.5% |
LOAD REGULATION | ±1.0% | ±1.0% |
SETUP, RISE TIME | 1500ms, 100ms/230VAC 3000ms, 100ms/115VAC at full load | |
HOLD UP TIME (TW.) | 16ms/230VAC 16ms/115VAC at full load | |
INPUT | VOLTAGE RANGE Note.4 | 90 – 264VAC 127 – 370VDC |
FREQUENCY RANGE | 47 – 63Hz | |
POWER FACTOR (Typ.) | PF>0.98/115VAC. PF>0.94/230VAC at full load | |
EFFICIENCY (Typ.) | 92.5% I | 93.% |
AC CURRENT (Typ.) | 4.8N115VAC 2.4A/230VAC | |
INRUSH CURRENT (Wp.) | 20N115VAC 35A/230VAC | |
LEAKAGE CURRENT | <2mA/ 240VAC | |
PROTECTION | OVERLOAD | 105 -130% rated output power |
Protection type : Constant current limiting, unit will shut down after 3 sec.,
re-power on to recover
OVER VOLTAGE| 29 – 33V| I 56 – 65V
Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE| Shut down o/p voltage, recovers automatically after
temperature goes down
EIMRONNB1T| WORKING TEMP.| -20 – +70°C (Refer to ‘Derating Curve”)
WORKING HUMIDITY| 20 – 95% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 – +85°C , 10 – 95% RH
TEMP. COEFFICIENT| ±0.03%/°C (0 – 50°C )
VIBRATION| Component:10 – 500Hz, 2G 10minJ1cycle, 60min. each along X, Y, Z
axes; Mounting: Compliance to IEC60068-2-6
SAFETY &
EMC (Note 4)| SAFETY STANDARDS| U1508, TUV BS EN/EN62368-1, EAC TP TC 004.
BSMI CNS14336-1 , IS13252(Part1y1EC60950-1(except for 48V) approved; (meet BS
EN/EN60204-1)
WITHSTAND VOLTAGE| 1/13-0/P:3KVAC 1/13-FG:2KVAC 0/P-FG:0.5KVAC
ISOLATION RESISTANCE| W-0/P, I/P-FG, 0/P-FG:>100M Ohms I 500VDC/25°C) 70% RH
EMC EMISSION| Compliance to BS EWEN55032 (CISPR32),BS EN/EN61204-3 Class B,BS
ENEN61000-3-2,-3,EAC TP TC 020,CNS13438 Class B
EMC IMMUNITY| Compftance to BS EN/EN61000-4-2,3,4,5,6,8,11,BS EN/EN55024,BS
ENIEN61000-6-2 (BS ENIEN50082-2),BS EN/EN61204-3, heavy industry level, EAC TP
TC 020
OTHERS| MTBF| 1041.6K hrs min. Telcordia SR-332 (Bellcore) ;146.8K hrs min.
MIL-HDBK-217F (25°C)
DIMENSION| 85.5’125.2’128.5mm (W’H’D)
PACKING| 1.5Kg; 8pcs/13Kg/0.9CUFT
NOTE
- M parameters NOT specially mentioned are measured at 230VAC input, rated load and 25.0 of ambient temperature.
- Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1 uf & 47uf parallel capacitor.
- Tolerance : in ckides set up tolerance. line regulation and load regulation.
- Installation clearances : 40mm on top, 20mm on the bottom. 5mm on the left and right side are recommended when loaded permanently with full power. In case the adjacent device is a heat source, 15mm dearance is recommended.
- Derating may be needed under low input voltage. Please check the derating curve for more details.
- The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system compiles with the EMC drectives. For gLidance on how to perform ewe EMC tests, pease refer to ‘EMI testing of component power su;ples.”
- The ambient temperature derating of 3.5t/1000m with fanless models and of 5.C/1000m with fan models tor operating altitude higher than 2000m(650011).
(as available on http://www.meanwell.com)
Product Liability Disclaimer : For detailed information, please refer to https://www.meanwell.com/serviceDisciaimeraspx
Block Diagram
Derating Curve
Output derating VS input
voltage
**Mechanical Specification
**
Installation Instruction
ADMISSIBLE DIN-RAIL:TS35/7.5
OR TS35/15
(For reference only. Not included with unit.)
This series fits DIN rail TS35/7.5 or TS35/15.
For installation details, please refer to the Instruction manual.
Installation Manual
Please refer to : http://www.meanwell.com/manual.html
References
- TÜV Rheinland - Home | US | TÜV Rheinland
- Global Trade Item Number (GTIN)-MEAN WELL Switching Power Supply Manufacturer
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>