NEO STORMER-QUAD-IP High Performace Outdoor Led Strobe Light User Manual

September 19, 2024
NEO

NEO STORMER-QUAD-IP High Performace Outdoor Led Strobe Light

PLEASE READ THE INSTRUCTIONS CAREFULLY BEFORE USE

OVERVIEW

STORMER QUAD IP

HIGH PERFORMANCE IP65 LED STROBE

Specifications

Source & Optics

  • Light source: 1320pcs RGBW SMD 5050 LEDs.
  • RGBW LED: 1.1W (R=0.2W, G=0.2W, B=0.2W, W=0.5W, RGBW=1.1W)
  • Beam angle : 60°
  • LUX @ 5M: R120 lux, G230 lux, B310 lux, W340 lux; full color 1000 lux.
  • Voltage: AC110-240V 50/60Hz

Effects

  • DMX-512 protocol 0-100% dimming control
  • DMX512 channels for speed and dimming Special Functions
  • Strobe : 0 ~ 30Hz DMX – 7/8/13/15/31 channels
  • Dimmer : 0-100%

Control

  • Control: 6 independent zones
  • DMX channels: 7/8/13/15/31 CH optional
  • Operational modes: Sound Control, DMX 512, Master/Slaver, Auto run.

Physical

  • LED display
  • IP Certificate : IP65
  • Dimensions: 490300125 mm
  • Weight: 10.5 Kg.

SAFETY INSTRUCTIONS

Please read the instruction carefully which includes important information about the installation, usage and maintenance.

TO GUARD AGAINST ELECTRIC SHOCK

  • Disconnect the fixture from AC power allow the flash capacitor to discharge for 1 minute before changing the lamp or fuse, and when not in use.
  • Do not remove the rear cover: there are no user serviceable parts inside.
  • Always ground (earth) the  fixture electrically.
  • Use only a source of AC power that complies with local building and electrical codes and has both overload and ground-fault protection.
  • Do not expose the fixture to rain or moisture.
  • Replace the lamp only as describe or have it replaced by a Strobe service technician.
  • To guard against UV radiation, burns, and fire.

NEVER OPERATE THE FIXTURE WITH THE FRONT GLASS OPEN, MISSING OR DAMAGED

  • Do not stare directly into the light. Never look at an exposed lamp while it is lit.
  • Replace the lamp when it becomes defective or worn out.
  • When replacing the lamp, allow the fixture to cool for at least 10 minutes before opening the fixture or removing the lamp.
  • Never attempt to bypass the fuse. Always replace defective fuses with ones of the specified type and rating.
  • Verify that the power feed cable is rated for the current draw of all connected fixtures.
  • Keep all combustible materials (for example fabric, wood,
  • Do not illuminate surfaces within 1 meter (39 inches)
  • Provide a minimum clearance of 0.1 meters (4 inches) around air vents.
  • Never place filters or other materials over the front glass cover.
  • The exterior of the fixture can reach temperatures up to 120° C (248° F).
  • Allow the fixture to cool for at least 15 minutes before handling.
  • Ensure that any supporting structure and/or hardware used can hold at least 10 times the weight of all the devices they support.
  • If suspending from a rigging structure, fasten the fixture to a rigging clamp. Do not use safety cables as the primary means of support.
  • Check that all external covers and rigging hardware are securely fastened.
  • Block access below the work area and work from a stable platform whenever installing, servicing or moving the fixtures.
  • Do not operate the fixture with missing or damaged covers, shields or any optical component.
  • Do not modify the fixture or install other than genuine RUSH.

INSTALLATION

MENU Address UP 0~512
DOWN 512~0
Channel 7 /8/13/15/31 optional, press ENTER button to confirm.
Monitor CH1-7/1-8/1-13/1-15/1-31
Auto Auto 00- Auto 36
Efleet on Auto Dimmer Value 0-225
Strobe Speed 0-225
Mas mode NO
Yes Slave

Master
Back.L| 60S/120S/300S
Temp| Temp1
Temp2
Info| Test1| Test2
Reset| Version
Dimmer curve| Curve 0-3
Dimmer control| Speed 0-7

When you press the MODEL button, it will give you some information to choose.
DMX ADD: Set DMX address
Push the UP or DOWN to choose the DMX Address from 001-512,or 512-001,and push ENTER to confirm.
This function is used to set or adjust the fixture’s starting DMX address.
Every device controlled by DMX has to have a unique starting address.
The addressing feature is what allows DMX to function properly.
The DMX address of a fixture is what allows it to communicate with a controller properly.

CHANNEL : Choose the different channels

This function allows you to choose the DMX Channel, there are 5 kinds of DMX Channels: 7DMX Channel, 8 DMX Channel, 13DMX Channel, 15CH and 31CH, the UP or DOWN button to choose the mode, and push ENTER to confirm.

AUTO RUN: You can choose different Auto-run Model from 00 to 20, each number has represented one effect, when you have made a choice of one, press the ENTER button to choose its speed, push the UP or DOWN button to lift the speed of strobe running.

PS: This mode is on the condition of Auto-run Mode.
The sensitivity adjustment of the strobe could be from 001-255, push the UP or DOWN to add the level of sensitivity to the device.
PS: 001 is the highest one, on the opposite, 255 is the lowest.

STROBE: It can work as a strobe in stead of natural light, flash rate can be from 1-25 times per second.
LED TEMP : It allows to display some details about the functionality of the card/cards and LEDs:
Current: Instantly detected operating temperature
Maximum: Maximum detected temperature
Minimum: Minimum detected temperature

TEMPERATURE CONTROL: When the surface temperature of strobe is higher than 75°C,it will gradually become darker than before, the lightness could be no more than 20% full lighting.

DMX CHANNELS

7 CHANNEL MODE

CHANNEL DMX VALUE DESCRIPTION
Channel 1 0 ~ 255 Dimmer
Channel 2 0 ~ 255 Intensity of Flash
Channel 3 0 ~ 255 Flash
Channel 4 0 ~ 255 Random strobe
Channel 5 0 ~ 255 Special effect
Channel 6 0 ~ 255 Speed of effect
Channel 7 0 ~ 255 Color change

8 CHANNEL MODE

CHANNEL DMX VALUE DESCRIPTION
Channel 1 001-255 Dimmer
Channel 2 001-255 Red
Channel 3 001-255 Green
Channel 4 001-255 Blue
Channel 5 001-255 White
Channel 6 001-255 Intensity of Flash
Channel 7 001-255 Special effect
Channel 8 001-255 Special of effect

13 CHANNEL MODE

CHANNEL DMX VALUE DESCRIPTION
Channel 1 001~255 Dimmer
Channel 2 001~255 Red
Channel 3 001~255 Green
Channel 4 001~255 Blue
Channel 5 001~255 White
Channel 6 001~255 Intensity of Flash
Channel 7 001~255 Special effect
Channel 8 001~255 Special of effect
Channel 9 001~255 Special of effect
Channel 10 001~255 Red(backlight)
Channel 11 001~255 Green(backlight)
Channel 12 001~255 Blue(backlight)
Channel 13 001~255 White(backlight)

15 CHANNEL MODE

CHANNEL DMX VALUE DESCRIPTION
Channel 1 001~255 Dimmer
Channel 2 001~255 Red
Channel 3 001~255 Green
Channel 4 001~255 Blue
Channel 5 001~255 White
Channel 6 001~255 Intensity of Flash
Channel 7 001~255 Flash
Channel 8 001~255 Random strobe
Channel 9 001~255 Random strobe
Channel 10 001~255 Special effect
Channel 11 001~255 Intensity
Channel 12 001~255 Red(backlight)
Channel 13 001~255 Green(backlight)
Channel 14 001~255 Blue(backlight)
Channel 15 001~255 White(backlight)

31 CHANNEL MODE

CHANNEL DMX VALUE DESCRIPTION
Channel 1 001~255 Dimmer
Channel 2 001~255 Red1
Channel 3 001~255 Green1
Channel 4 001~255 Blue1
Channel 5 001~255 White1
………….. ………… …………
Channel 22 001~255 Red6
Channel 23 001~255 Green6
Channel 24 001~255 Blue6
Channel 25 001~255 White6
Channel 26 001~255 Intensity of Flash
Channel 27 001~255 Flash
Channel 28 001~255 Random strobe
Channel 29 001~255 Special effect
Channel 30 001~255 Special of effect
Channel 31 001~255 Intensity

CLEANING & MAINTENANCE

The following points have to be considered during the inspection:

  1. All screws for installing the devices or parts of the device have to be tightly connected and must not be corroded.
  2. There must not be any deformations on the housing, color lenses, fixations and installation spots (ceiling, suspension, trussing).
  3. Mechanically moved parts must not show any traces of wearing and must not rotate with unbalances.

CAUTION!
Disconnect from mains before starting maintenance operations.

DMX cables and connections to ensure the integrity of the physical network. In order to make the lights in good condition and extend the life time, we suggest a regular cleaning to the lights.

  1. Clean the inside and outside lens each week to avoid the weakness of the lights due to accumulation of dust.

  2. Clean the fan each week.

  3. A detailed electric check by approved electrical engineer each three month, make sure that the circuit contacts are in good condition, prevent the poor contact of circuit from overheating.

  4. The cleaning of external optical lenses must be carried out periodically to optimize light output. Cleaning schedules for lighting fixtures vary greatly depending on the operating environment.

  5. It is therefore impossible to specify precise cleaning intervals for the fixture, environmental factors that may result in a need for frequent cleaning include:
    A: Use of smoke or fog machines.
    B: High airflow rates near air conditioning vents, for example.
    C: Presence of cigarette smoke.
    D: Airborne dust (from stage effects, building structures and fittings or the natural environment at outdoor events, for example.

  6. Use gentle pressure only when cleaning, and work in a clean, well-lit area. Do not use any product that contains solvents or abrasives, as these can cause surface damage.

TROUBLESHOOTING

This section describes a few common problems that may occur during operation and provides some suggestions for easy troubleshooting.

A. LIGHTS CAN’T WORK, NO LIGHTS OUT

  1. Check power connection, the fuse whether is okay.
  2. Check power input whether correct.

B. CAN’T DMX CONTROL.

  1. DMX signal indicator must be on, if not, check the DMX cable.
  2. If DMX signal is OK, check the DMX address whether set OK.
  3. If DMX signal not consistent, check the DMX port connect.

C. SOUND ACTIVATION DOES NOT WORK

Potential cause: the fixture does not react to the beat of music.

REMEDIES: Ensure that fixture is not connected to a DMX signal Tap the microphone to ensure that it is functioning, the fixture should react when in sound activation mode.

D. FIXTURE DOES NOT RESPOND TO DMX CONTROL

Potential cause: fault in the DMX net work due to connector or cable damaged, or incorrect DMX addressing, or potential interference from proximity to a high voltage installation.

REMEDIES: Check that the fixture DMX LED is on, and if not, check all.

NEO STORMER QUAD IP