SHOWVEN SPARKULAR Waver Fall User Manual

September 17, 2024
Showven

SPARKULAR Waver Fall

“`html

Specifications:

  • Manufacturer: Showven Technologies Co., Ltd.

  • Model: HC8200

  • Max. Effect Height:

    • LARGE: 4m (Safety Radius: 5m, Safety Distance at Firing
      Direction: 1.5m)

    • LARGE I: 5m (Safety Radius: 6m, Safety Distance at Firing
      Direction: 1.5m)

    • LARGE II: 7m (Safety Radius: 8m, Safety Distance at Firing
      Direction: 1.5m)

Product Usage Instructions:

Safety Instructions:

Ensure a safety radius around the machine of 1.5m. No person or
flammable materials should be within this radius.

In windy environments, adjust the safety distance based on wind
direction and speed.

Always wear safety goggles when entering the safety zone to
protect against eye injuries from sparks and consumables.

Operation Panel:

Use the keypad area to navigate through the menu options:

  • MENU: Press to enter the settings interface
  • UP: Move parameter values up
  • DOWN: Move parameter values down
  • MONI: Monitor the status of the main parts inside the
    machine

Display Interface:

The main interface provides information on the machine’s
status:

  • Red background color in DMX area indicates DMX connection

  • Red background color in TEMP area indicates heating chamber
    temperature has reached the set temperature

  • Indicator light status on power switch provides information on
    heating up and readiness for firing

Set Up Menu:

To access the setup menu, press MENU. Navigate through the menus
using LEFT and RIGHT buttons. Press EDIT to enter specific menus
and adjust parameters. Remember to press SAVE to save the
settings.

FAQ:

Q: What should I do if the machine displays an error code?

A: Refer to the error code explanations
provided in the manual. For example, E0 indicates a systematic
error, E1 relates to motor conditions, and so on. Follow the
instructions to troubleshoot or seek professional assistance if
needed.

“`

USER MANUAL SPARKULAR® waverFALL
V1.1 2024/07/02
Showven Technologies Co., Ltd.

Thanks for choosing SPARKULAR® waverFALL, we wish it will sparks up your show. Please read the following manual carefully before operating this product.
Safety Instructions
Unauthorized repair are prohibited, it may cause serious incident. SPARKULAR® waverFALL can be used in rain, please keep the device dry after use. Make sure lid of feeding hopper are well covered when use SPARKULAR® waverFALL. Consumable should keep away from moisture and stored in a dry sealed environment. Check whether there is consumable aggregate in the output nozzle both before and after
each show, if any, please clean it up, or it will affect the firing effect, damage machine, even cause serious incident. There will be some sparks drop to ground, make sure there are no flammable objects such as carpet on the ground within the safety radius of the machine. The SPARKULAR® waverFALL power supply cable maximum allowed cascade of 6pcs (220V version) / 3pcs (110V version), exceed connecting may result in damage or even cause fire. Cover the output nozzle of SPARKULAR® waverFALL is forbidden, inspect the machine before each show, making sure no objects or material will block the output nozzle. Never touch the nozzle of SPARKULAR® waverFALL danger of getting burnt. Never touch the sparks which shooting out from the nozzle. Make sure no staff, audience and flammable materials stays under the SPARKULAR® waverFALL.

Safety Distance

Safety distance for SPARKULAR® waverFALL divided into two parts safety radius around

machine (a) and safety distance at firing direction (b). No person and flammable materials are

allowed to stay inside the safety isolation zone when SPARKULAR® waverFALL was armed.

The safety radius around machine of 1.5m.

For safety distance at firing direction equals to maximum firing height + 1m. SPARKULAR®

waverFALL with maximum 90 waving firing angles, when firing wave sequence the safety

isolation zone is a three-dimensional sector area.

HC8200 Type

Max. Effect Height

Safety Radius around Safety Distance at

SPARKULAR (a)

Firing Direction (b)

LARGE

4m

5m

LARGE I

5m

1.5m

6m

LARGE II

7m

8m

The SPARKULAR® WAVERFALL safety isolation zone is a three-dimensional space with a cross-

section of 180° sector enclosed by a and b (check below diagram). We can understand it as a

safety area formed by a safety column with diameter of a, height of b rotate of ±90 degrees.

Unauthorized persons and objects are strictly prohibited from entering. Depending on the

firing sequence / angles the sector area changes accordingly.

In windy environment, increase the safety distance according to the wind direction and speed.

Sparks and consumables from the machine can lead to serious eye injury. Always wear safety

goggles when enter the safety zone.

Description
SPARKULAR® waverFALL is 180°waving spark fall effect originally developed by SHOWVEN. It can firing in any single direction between -90° to 90° or in waving sequences. With 72 preset firing sequences and various editable sparks effect brings infinite creativity to your stage. It can also combined with SPARKULAR WAVER to generate a spark effect in any direction of 360 degrees.
Technical Specifications
DIMENSION: 309 305 285mm WEIGHT: 17kg VOLTAGE: AC200-240V / AC100-120V, 50/60Hz WORK POWER: 500W HC8200 CONSUMPTION: 22g/min EFFECT HEIGHT ADJUSTBLE: YES EFFECT ANGLE ADJUSTBLE: -90°~ 90° (180° waving angles) INTERFACE: 3-pin and 5-pin XLR, POWER IN/OUT CONTROL: 6 DMX channels WORK TEMP.: -20 C~40 C CONSUMABLE AND EFFECT HEIGHT: LARGE (3-4m), LARGE I (4-5m), LARGE II (5-7m)

Structure of SPARKULAR® waverFALL
1. Feeding Hopper Lid 2. Clamp 3. ARM alarming light 4. Display Screen 5. Power Switch 6. Fuse 7. Power IN 8. Power OUT 9. 3-PIN DMX OUT 10. 3-PIN DMX IN 11. 5-PIN DMX OUT 12. 5-PIN DMX IN
Operation Panel
1. Keypad area

MENU: Press enter setting interface UP: Parameter up DOWN: Parameter down MONI: Status monitoring of main part inside machine 2. Monitoring Interface From this interface, we can check the voltage and motor status of machine.
3. RFID area
RFID card come with consumable HC8200 bags, swiping card to identify parameters and types of granules. The RFID card is disposable, one card can only use one time. Each card can increase single machine 20min working time, the maximum recharge time for SPARKULAR® waverFALL is 30min. 4. ARM alarming light
ON: DMX connected or wireless remote function ON. BLINK: DMX armed, ready for firing OFF: No DMX connection and wireless remote function OFF.

Display Interface
1. Main Interface:

Background color of DMX area: red means DMX connected. Background color of TEMP area: red means heating chamber temp. reached setting temp. machine is ready for firing. Indicator light status on power switch: flash means machine is heating up, long on means temp. reached setting temp.

2. Error information Error information E0 System IC E1 Motor condition E2 Temp. Sensor E3 P Temp. Over E4 Time Remain E5 K Temp. Over
E6 Heat Fail
E7 Tip Over

Explanation Systematic error Blower motor, shaft motor or feeding motor error Temperature sensor is not connected or damaged Machine shutdown due to chassis over temperature Firing time is insufficient, please swipe RFID card Machine shutdown due to heating chamber over temperature Heating fail, problem on heating PCB or mainboard, if disappear automatically, please check the power supply. Tilt sensor activated when machine slant over 45 degrees

3. Set Up Menu Press “MENU” enter setup menu, press LEFT, RIGHT to choose main menu, advanced menu or factory menu. Press “EIDT” can entering related menu and setting up related parameters.

4. Main Menu Parameters in main menu show in below table, press “UP”/ “DOWN” to change the value, please remember to press “SAVE” to save the setting.

Options

Range Default

Explanation

Set DMX Address 1-512

1 Set DMX Address

Manual Heat

ON/OFF

OFF Manual heat ON/OFF setting

Manual Fountain ON/OFF

OFF Manual Fountain ON/OFF setting

Sequence

2 – 72

2 Preset sequence setting

Max. Angle

0°~90°

90° Max. Angle limit

Min. Angle

-90°~0°

-90° Min. Angle limit

Invert

ON/OFF

OFF When turned on, all angles will be mirrored.

Head to middle ON/OFF

When ON and Channel 1 DMX value is 0, output ON nozzle will back to middle position after running a
preset sequence.

5. Advanced Menu

Options

Range

Default

Explanation

Set Temperature Auto Clear Delay

400-620 0.1-0.9s

580

Setup SPARKULAR® heat chamber temperature

0.1s

Automatic clear material time setting

Wireless 2.4G

ON/OFF

OFF 2.4G wireless function setting

LCD Backlight

ON/OFF

ON

LCD backlight setting

Density

70-100

100 Feeding amount

Mode Selection

Factory Mode User Mode

Factory mode is for engineer only.
User Mode When in Factory mode machine can’t controlled by DMX console

Default Parameter

ON/OFF

OFF Parameters reset to default setting

Motor Protect

ON/OFF

ON

Motor protect function

Tip Over

ON/OFF

Tilt function switch, when machine

ON

slant over 45 degree it will stop

working.

Standby Switch Motor Disabled

ON/OFF ON/OFF

OFF

When ON, the machine can firing only when heating up was finished

OFF

Motor can’t waving when OFF

Key Sound

ON/OFF

ON

Keypad press sound setting

Middle Set

ON/OFF

When it is ON, after firing nozzle OFF will move to around 15 degree and
then back to middle slowly

*For better performance of SPARKULAR® waverFALL, please don’t change the default value

without permission from SHOWVEN®.

6. DMX Channel Mode

SPARKULAR waverFALL occupies 6 operational channels.

Channel CH1 CH2
CH3

Function Manual Angle setup
Manual Nozzle Waving Speed setup
Firing ON/OFF

Value 0~255: angle change from -90° to 90° 128: straight upward (0°) 0 and 255: Max Speed 1~254: Speed increase 0~15: Firing OFF 16~90: Firing height low 91~170: Firing height medium 171~255: Firing height high Maxi. Single firing duration is 60s

CH4

n/a

Reserved

0-2: no preset sequence

CH5

Preset sequence setup 3-255: preset sequence

DMX value = 2 + Sequence No.*2.55 (ROUND OFF)

0~49: Heating Up OFF (Emergency Stop)

CH6

Mode setup

50~200: Heating Up ON

201~255: Heating Up OFF (Emergency Stop)

Channel 1 (CH1): Manual Angle Setup SPARKUALR waverFALL output nozzle can be stayed at any angle between -90° to 90°, below is a list of typical angles used in our preset sequence with related DMX value.

Angle No.

Angle

DMX value

1

-90°

5

2

-75°

24

3

-60°

47

4

-45°

66

5

-30°

85

6

-15°

108

7

128 or 0

8

15°

148

9

30°

169

10

45°

190

11

60°

213

12

75°

234

13

90°

255

Angle Definition SPARKUALR waverFALL with waving output nozzle firing between -90° to +90°, we devided 180 degree into 13 firing directions as below (audience side view).

Channel 5 (CH5): Firing Sequence

SPARKULAR waverFALL has 72 preset sequences, operator use related channel DMX value or

sequence No. to access certain sequence. Below, you can find sequence list.

No.

Ignition angle

Description

Firing Duration

1

Any angle

2

-90°

3

-75°

4

-60°

5

-45°

6

-30°

7

-15°

8

9

15°

10

30°

11

45°

12

60°

13

75°

14

90°

15

(-90°) ~ 90°

16

90°~ (-90°)

17

(-90°)~ 90° ~(-90°)

18

(-75°)~ 75°~ (-75°)

Clear material Fixed angle firing Fixed angle firing Fixed angle firing Fixed angle firing Fixed angle firing Fixed angle firing Fixed angle firing Fixed angle firing Fixed angle firing Fixed angle firing Fixed angle firing Fixed angle firing Fixed angle firing Slow waving once Slow waving once Slow waving once Slow waving once

Depends on CH3 Depends on CH3 Depends on CH3 Depends on CH3 Depends on CH3 Depends on CH3 Depends on CH3 Depends on CH3 Depends on CH3 Depends on CH3 Depends on CH3 Depends on CH3 Depends on CH3 Depends on CH3
8s 8s 14s 12s

CH5 DMX Reference
Value 3-5 6-7 8-10
11-12 13-15 16-17 18-20 21-22 23-25 26-28 29-30 31-33 34-35 36-38 39-40 41-43 44-45 46-48

19

(-60°)~ 60° ~ (-60°)

Slow waving once

10s

20

(-45°)~ 45° ~ (-45°)

Slow waving 3 times

17s

21

(-30°)~ 30° ~ (-30°)

Slow waving 3 times

12s

22

(-15°)~ 15° ~ (-15°)

Slow waving 3 times

7s

23

(-90°)~ 90° ~ (-90°) Medium waving 5 times

12s

24

(-75°)~ 75° ~ (-75°) Medium waving 5 times

10s

25

(-60°)~ 60° ~ (-60°) Medium waving 5 times

8s

26

(-45°)~ 45° ~ (-45°) Medium waving 5 times

7s

27

(-30°)~ 30° ~ (-30° Medium waving 5 times

5s

28

(-15°)~ 15° ~ (-15°) Medium waving 5 times

3s

29

(-60°)~ 60° ~ (-60°)

Fast waving 10 times

5s

30

(-45°)~ 45° ~ (-45°)

Fast waving 10 times

5s

31

(-30°)~ 30° ~ (-30°)

Fast waving 10 times

4s

32

(-15°)~ 15° ~ (-15°)

Fast waving 10 times

3s

33

(-75°)~ 0° ~ (-75°)

Fast waving 10 times

4s

34

(-60°)~ 0° ~ (-60°)

Fast waving 10 times

3s

35

(-45°)~ 0° ~ (-45°)

Fast waving 10 times

2s

36

(-30°)~ 0° ~ (-30°)

Fast waving 10 times

2s

37

75° ~ 0° ~ 75°

Fast waving 10 times

5s

38

60° ~ 0° ~ 60°

Fast waving 10 times

4s

39

45° ~ 0° ~ 45°

Fast waving 10 times

3s

40

30° ~ 0° ~ 30°

Fast waving 10 times

3s

41

(-90°)~ 0° ~ (-90°)

Slow waving twice

11s

42

(-75°)~ 0° ~ (-75°)

Slow waving twice

10s

43

(-60°)~ 0° ~ (-60°)

Slow waving twice

8s

44

(-45°)~ 0° ~ (-45°)

Slow waving twice

6s

45

(-30°)~ 0° ~ (-30°)

Slow waving twice

5s

46

90° ~ 0° ~ 90°

Slow waving twice

11s

47

75° ~ 0° ~ 75°

Slow waving twice

10s

48

60° ~ 0° ~ 60°

Slow waving twice

8s

49

45° ~ 0° ~ 45°

Slow waving twice

6s

50

30° ~ 0° ~ 30°

Slow waving twice

5s

51

(-90°)~ 0° ~ (-90°)

Medium waving 5 times

7s

52

(-75°)~ 0° ~ (-75°)

Medium waving 5 times

6s

53

(-60°)~ 0° ~ (-60°)

Medium waving 5 times

5s

54

(-45°)~ 0° ~ (-45°)

Medium waving 5 times

4s

55

(-30°)~ 0° ~ (-30°)

Medium waving 5 times

3s

56

90° ~ 0° ~ 90°

Medium waving 5 times

7s

57

75° ~ 0° ~ 75°

Medium waving 5 times

6s

58

60° ~ 0° ~ 60°

Medium waving 5 times

5s

59

45° ~ 0° ~ 45°

Medium waving 5 times

4s

60

30° ~ 0° ~ 30°

Medium waving 5 times

3s

61

90° ~ 45° ~ 90°

Slow waving 3 times

10s

49-50 51-53 54-56 57-58 59-61 62-63 64-66 67-68 69-71 72-73 74-76 77-79 80-81 82-84 85-86 87-89 90-91 92-94 95-96 97-99 100-101 102-104 105-107 108-109 110-112 113-114 115-117 118-119 120-122 123-124 125-127 128-130 131-132 133-135 136-137 138-140 141-142 143-145 146-147 148-150 151-152 153-155 156-158

62

90° ~ 30°~ 90°

Slow waving 3 times

13s

63 (-90°) ~ (-45°) ~ (-90°) Slow waving 3 times

10s

64 (-90°) ~ (-30°) ~ (-90°) Slow waving 3 times

12s

65

(-90°) ~ 0°

Slow waving gradually decreases angle

18s

66

90° ~ 0°

Slow waving gradually decreases angle

18s

67

(-90°) ~ 90°

Slow waving gradually decreases angle

41s

68

0° ~ (-90°)

Slow waving once

5s

69

(-90°) ~ 0°

Slow waving once

5s

70

0° ~ 90°

Slow waving once

5s

71

90° ~ 0°

Slow waving once

5s

72

Fixed angle firing

12s

DMX control example 1: firing sequence No. 42
1. Set output nozzle straight up CH1 = 128, CH2 = 0, CH3 = 0, CH4 = 0, CH5 = 0, CH6 = 128
2. Set preset Sequence No. 42 CH1 = 128, CH2 = 0, CH3 = 0, CH4 = 0, CH5 = 108, CH6 = 128
3. Firing CH1 = 128, CH2 = 0, CH3 = 255, CH4 = 0, CH5 = 108, CH6 = 128

159-160 161-163 164-165 166-168
169-170
171-173 174-175 176-178 179-180 181-183 184-185

DMX control example 2: firing sequence No. 8, firing time 10s 1. Set output nozzle straight up
CH1 = 0, CH2 = 0, CH3 = 0, CH4 = 0, CH5 = 0, CH6 = 128 2. Set preset Sequence No. 8
CH1 = 0, CH2 = 0, CH3 = 0, CH4 = 0, CH5 = 21, CH6 = 128 3. Firing, default firing duration is 60s
CH1 = 0, CH2 = 0, CH3 = 255, CH4 = 0, CH5 = 21, CH6 = 128 Keep 10s. 4. Firing OFF CH1 = 0, CH2 = 0, CH3 = 0, CH4 = 0, CH5 = 21, CH6 = 128
7. Wireless Control Mode:
When use remote controller, please disconnect DMX cable connection, set machine to Wireless 2.4G to ON status. Match machine with remote controller by Press “A” on remote controller
when machine at Wireless Control interface.
A: OFF / SET, Firing OFF, SET means match machine with remote controller.
B: Firing, vertical up (0°)
C: Firing, according to the sequence setting on machine
D: Clear Material 3s. Please replace the battery when the indicator light on remote controller is weak. Battery mode: 9V stacked battery. Remote controller for SPARKULAR waverFALL is optional accessory.

8. SHOWVEN HOST CONTROLLER ZK6200/6300 control: When use our host controller control SPARKULAR® waverFALL please press “F3” and switch the device on HOST CONTROLLER to CIRCLE FLAMER-6CH. Due to host controller with bidirectional communication with SPARKULAR® waverFALL, for each unit of machine please do allocate a unique DMX address as below: SPARKULAR No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
DMX Address 1 7 13 19 25 31 37 43 49 55 61 67 73 79 85 91 97 103 IMPORTANT NOTICE: Allocate same DMX address to different machine will cause signal interference and leads to malfunction of machine.
Operation Guide
1. Install SPARKULAR® waverFALL a) SPARKULAR® waverFALL suggest to be hanged horizontally. b) Make sure the machine is securely installed to avoid falling, make sure to install extra safety
rope for each machine. c) Check carefully the output nozzle of each machine, make sure the output nozzle is in good
shape and there is no powder aggregate.

2. Fill SPARKULAR® waverFALL

a) Open powder bags and fill the feeding hopper.

b) Choose correct consumable according to the hanging height and safety distance.. SPARKULAR® waverFALL can only use HC8200 LARGE / LARGE I / LARGE II.

HC8200

Effect length (Low Output)

Effect length (High Output)

LARGE

3m

4m

LARGE-

4m

5m

LARGE-

5m

7m

c) Please be noted that there may sparks or remains fall to the ground. Make sure no

flammable material on ground in the safety zone.

d) Make sure the lid of hopper is locked tight after filling. SAFETY NOTICE: Accidentally burning of consumable HC8200 in the hopper can only use sands to extinguish.
3. Connect Power / DMX cable a) Connect a power cable to the POWER IN socket of SPARKULAR® waverFALL. Connect the
other end of power cable to the power source. Make sure power supply in consistent with the rated voltage of the equipment, and the socket must well grounded. b) If connect machine in sequence, please connect a power link cable to the POWER OUT of previous machine, connect the other end of the power link cable to POWER IN of the next machine. c) The SPARKULAR® waverFALL power supply cable maximum allowed cascade is 6 units (220V version) / 3pcs (110V version). Do not connect exceed units to a single electrical circuit. d) Power ON all SPARKULAR® waverFALL. e) Assign DMX address for each unit of SPARKULAR® waverFALL. If use SHOWVEN host controller or FXcommander to control the machine please allocate a unique DMX address for each unit of machine. If use remote controller to control SPARKULAR® waverFALL wirelessly, please set machine to wireless ON status and match machine with remote controller. For DMX cable control please execute below operations (f to h). f) Connect a DMX cable to the DMX IN socket of first unit of SPARKULAR® waverFALL, connect the male connector end of DMX cable to your DMX controller (FXcommander, HOST CONTROLLER, light console etc). g) Connect a DMX cable to the DMX OUT of previous machine, and the other end of to the DMX IN of next machine. Connect all devices in series in this way. h) Plug in a DMX terminator into the DMX OUT in last unit of machine to improve signal reliability. Signal amplifier is required for long distance (>200m) DMX signal transmission (SHOWVEN DMX splitter 8 with bidirectional signal transmission, thus can get signal feedback from device).
4. Activate SPARKULAR® waverFALL by swipe RFID card a) Swipe an RFID card. Read the card as show below. SPARKULAR® waverFALL shows time
remain if read successfully. SPARKULAR® waverFALL report E4 when remaining time is less than 10 minutes. b) Please note each RFID card come with 200g package HC8200 can increase single machine 20min working time, the maximum recharge time for SPARKULAR® waverFALL is 30min, when time remain reached 30min, it can’t recharge anymore RFID card.

CN. 00000001
5. Programming and Firing a) Programming SPARKULAR® waverFALL, set the firing sequences etc. b) Heating up, it takes few minutes, it varies according to the voltage and environment
temperature. c) Make sure the prescribed safety zone of related firing sequences are clear. d) Suggest to clear material for SPARKULAR® waverFALL before firing. e) Firing. In order to prevent overheat in the heating chamber and protect machine, the
maximum continuous firing time for SPARKULAR® waverFALL is 60s. f) The operator should always have a clear view of the device, so that he/she can stop the
show immediately when there is danger. g) Running preset sequence No.1 to clear material for SPARKULAR® waverFALL after show,
clear material will remove the remaining particles from heating chamber. NOTE: If use SHOWVEN HOST CONTROLLER ZK6200/6300 to control the firing, please press “F3” to choose “CIRCLE FLAMER-6CH”, then set the firing sequence, as for preset sequence the firing duration is fixed, so please set firing duration 1s. Please do allocate different DMX address for each unit of SPARKULAR WAVERFALL (6 channels), otherwise it will cause signal interference.
6. Turn Off and clean up a) Power off SPARKULAR® waverFALL, allow SPARKULAR® waverFALL to cool down. b) Disconnect all POWER and DMX cables. c) Empty the remaining HC8200 in hopper, and store the remaining HC8200 in a dry sealed
bottle for next time use. Never touch the output nozzle of SPARKULAR® waverFALL when empty the hopper. DANGER OF GET BURNT! d) Operators can use handheld vacuum cleaner to empty the feeding hopper. Do make sure the machine was cool down when clean it. Do NOT use high-power vacuum cleaners to avoid hot consumables being sucked into the vacuum cleaner from the heating chamber and cause fire. e) Clean the surroundings to remove powder residues.
Maintenance
a) Empty the feeding hopper before shipment of machine. b) Empty the feeding hopper if long time not use, for high humidity environment we suggest
to empty feeding hopper after each show. c) Clear material both before and after the show.

Warranty Instructions
Sincere thanks for your choosing our products, you will receive quality service from us The product warranty period is one year. If there are any quality problems within 7 days after
shipping out from our factory, we can exchange a brand new same model machine for you We will offer free of charge maintenance service for machines which with hardware
malfunction (except for the instrument damage caused by human factors) in warranty period. Please don’t repair machine without factory permission
Below situations NOT included in warranty service: Damage caused by use other type of consumable which is not originally from SHOWVEN®. Damage caused by improper transportation, usage, management, and maintenance, or
damage caused by human factors; Disassemble, modify or repair products without permission; Damage caused by external reasons (lightning strike, power supply etc.) Damage caused by improper installation or use;
For product damage not included in warranty range, we can provide paid service. Invoice is necessary when applying for maintenance service from SHOWVEN®.

Showven Technologies Co., Ltd.
Tel: +86-731-83833068 Web: www.showven.cn E-mail: info@showven.cn Add: No.1 Tengda Road, Liuyang Economic & Technical Development Zone, Changsha, Hunan,
410300, P.R.China

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>