SHOWVEN SonicBoom X SmokeJet User Manual

June 5, 2024
Showven

USER MANUAL
SONICBOOM ® X SMOKEJET
V2.0

Showven Technologies Co., Ltd.

★Please read this manual carefully before operating this product.
★Warranty card is attached in the manual, please keep it well.

▲SAFETY CONSIDERATIONS

  • Unauthorized repairs are prohibited, it may cause a serious incident
  • Independent smoke column color change
  • Patented pipeline integration technology, ensure 0.3s instant smoke burst
  • Automatic constant pressure design, highly consistent smoke effect
  • 220V version SONICBOOM Support 1500W half power mode, easier main power supply.
  • Over temp. alarm, no fuel alarm, over-voltage alarm, etc. multi safety status monitoring. Safer for use, easier for maintenance.
  • Support manual operation on the machine control panel
  • DMX control, 11 channels and 1 channel optional
  • Only use SHOWVEN original FX-S/FX-ST fog fluid, other fluids may lead to clogging or malfunction.
  • FX-S is a quick dissipating fog fluid, the smoke dissipates in seconds, it is perfect choice for creating instant smoke column.

▲Description

SONIC BOOM X SOMEKJET can generate up to 10m smoke column effects similar as CO2 jet. 35 pcs of LED ensure the multicolor of smoke. Combined with SHOWVEN® original FX-S pro quick dissipating fog fluid guarantee the fast dissipating of the smoke.

▲Technical Specifications

  • MODEL: SONICBOOM® X
  • DIMENSION: 482×408×215mm
  • WEIGHT: 17.2kg
  • VOLTAGE: 220V/110V, 50/60Hz
  • FUSE:15A/250V
  • POWER: 3000W/1500W(220V), 2000W(110V)
  • LED POWER: 5W×35pcs
  • MAX OUTPUT DISTANCE: 10m
  • MAX CONTINUOUS OUTPUT DURATION: 8s
  • SMOKE OUTPUT: 55000cuft/min
  • TANK CAPACITY: 2.5L
  • FLUID CONSUMPTION RATE: 5min/L
  • DMX CHANNELS: 1/11
  • CONSUMABLES: FX-S

▲Operation Panel

  1. Control button area
    SHOWVEN SonicBoom X SmokeJet - Control button MENU: switch through the setup menu
    + : Parameter up; multiplex “TIMER” (smoke output time)
    : Parameters down; multiplex “VOLUME” (smoke output start)
    ENTER: confirm and save parameters (screen will blink once when save successfully); multiplex “STOP”.
    NOTE: Screen will switch to the main interface automatically if not press any button in a long time.

▲Interface

  1. Main interface:
    SHOWVEN SonicBoom X SmokeJet - InterfaceFirst Line: DMX address, “:” blinks when there is DMX in signal.
    Second Line: shows machine core temperature and pressure. The machine is ready for operation only when both temperature and pressure values are close to 100%.

  2. Error information:
    Error information|

Explanation

---|---
E0 System IC| Circuit fault
E1 Pressure| Pressure faults, no fog fluid or pump error
E2 K temp. Sensor| Temperature sensor fault
E3 Evacuate| Evacuate fuel pipe fault
E5 Temp Over| Circuit fault
E6 Heat Fail| Heating element damage or circuit fault
3. Setting Menu:
Press “MENU” switch through setup menu.

Options

| Range|

Explanation

---|---|---
DMX 512 Address| 1~506| Set DMX address
Power Regulation| Standard/Half Power| Setting working power for the machine
Color Optional| 0~10| LED color set when manual firing
Single Channel| ON/OFF| Single channel mode set
4. LED color setting:
0: LED OFF
1: RED
2: GREEN
3: BLUE
4: PINK
5: PURPLE
6: ORANGE
7: YELLOW
8: SKY BLUE
9: WHITE
Above setting disabled when use DMX console, LED color determined by setting on console.
When choosing 1 channel mode, LED color is determined by a single channel, DMX value, and related color as below:

Color

| SMOKE OFF| RED| GREE N| BLUE| PINK| PURPL E| ORAN GE| YELLO W| SKY BLUE| WHIT E| Rando m|

LED OFF

---|---|---|---|---|---|---|---|---|---|---|---|---
DMX value| 0-40| 41- 60| 61-80| 81- 100| 101- 120| 121- 140| 141- 160| 161- 180| 181-200| 201- 220| 221- 235| 236- 255
5. Advanced Menu:
Press “MENU” for 3s, enter the advanced setting interface

Item

| Value|

Explanation

---|---|---
Manual Evacuate| ON/OFF| Manual Evacuate when pressure always insufficient
Interval Set| 0-200| Interval time
Duration Set| 0-8| Smoke output duration
Wireless Remote| ON/OFF| Wireless ON/OFF switch
Language| Chinese/English| Language switch
Manual Pump| ON/OFF| For maintenance

▲DMX Channel

11 DMX channels for SONIC BOOM.

Channels

|

Function

---|---
Channel 1| Firing: (0-9) OFF, ( 10-255) ON
Channel 2| Inner LED RED: (0-9) OFF, (10-255) LED brightness increase
Channel 3| Inner LED GREEN: (0-9) OFF, (10-255) LED brightness increase
Channel 4| Inner LED BLUE: (0-9) OFF, ( 10-255) LED brightness increase
Channel 5| Outer LED RED: (0-9) OFF, (10-255) LED brightness increase
Channel 6| Outer LED GREEN, (0-9) OFF, (10-2551) LED brightness increase
Channel 7| Outer LED BLUE, (0-9) OFF, (10-255) LED brightness increase
Channel 8| LED Random: (0-9) OFF, (10-255) LED random color, use together with channel 9.
Channel 9| LED color change speed: (0-9) OFF, (10-255) LED color change speed increase
---|---
Channel 10| LED strobe: (0-9) OFF, (10-255) LED strobe increase
Channel 11| LED dimmer, (0-9) OFF, (10-255) LED brightness increase

NOTE: Manual function disabled when DMX connected.

▲E1 Pressure error explanation

In order to protect the pump, SONICBOOM will be running a self-check program to find out whether there is fog fluid in the fuel pipe.

  1. E1 pressure error activation
    When there is no fog fluid in the fuel tank, the system can not reach preset pressure or even turn on for a long time. The pump will stop working, and report E1.

  2. Way to clear the E1 error
    Fill the fog fluid tank, then restart the machine.
    Press “VOLUME” to reset.
    DMX Channel 1, start a firing.

▲ Upside-down installation

For upside-down installation, please remove the bottom panel of the fluid tank, and installed it on the other side (top panel), the fluid tank should be installed upward as below picture. For safety, hanging installation should install a safety rope.

▲ Maintenance

  1. Use SHOWVEN original fog fluid for the best effect of SONIC BOOM. The warranty will be void if any other type of fluid is used.
  2. Don’t disassemble the machine by an unauthorized person, modifications to the machine are not allowed.
  3. Excessive dust, liquid or dirt, etc on the equipment will affect the performance of the machine and cause poor heat dissipation. Remove dust with air compressor, vacuum or soft brush. Use a damp cloth to clean the case.
  4. Before storing the machine, run distilled water through the system to help avoid condensing the pump or heater.
  5. To keep the best status and performance of the machine, it is recommended to run the machine at least once per month.
  6. After continuous use of 40h (or 1-2month), please use 35% vinegar with 65% distilled water to wash the pump and pipe system by running the machine 10-15 times.

▲Possible reason for the block of atomizer

For the healthy and best status of the machine, please do use SHOWVEN original fog fluid.
A. Fluid spill: heat can’t effectively transmit to fog fluid, leading to insufficient atomization of the fog fluid in the heating pipe.
Possible Reason 1: Use another type of low-quality fog fluid instead of SHOWVEN’s original fog fluid.
Possible reason 2: Use inappropriate fog fluid. For different types of fog fluid, the atomization temperature is different.
B. Heating aluminum pipe clog: an early symptom of heating aluminum pipe clog is fog fluid spill caused by insufficient atomization. Use other brand fluids or not make regular maintenance for a long time will definitely lead to pipe clog.
C. solution for the above problem: Use SHOWVEN original fog fluid. Make regular maintenance (every 1-2month). Use 35% vinegar with 65% distilled water to wash the pump and pipe system by running the machine 10-15 times.

Warranty Instructions

▲Sincere thanks for your choosing our products, you will receive quality service from us
▲The product warranty period is one year. If there are any quality problems within 7 days after shipping out from our factory, we can exchange a brand new same model machine for you
▲We will offer free-of-charge maintenance service for machines with hardware malfunction (except for the instrument damage caused by human factors) during the warranty period. Please don’t repair the machine without factory permission

×Below situations NOT included in warranty service:

  1. Damage caused by improper transportation, usage, management, and maintenance, or damage caused by human factors;
  2. Disassemble, modify or repair products without permission;
  3. Damage caused by external reasons (lightning strike, power supply etc.)
  4. Damage caused by improper installation or use;
    For product damage not included in the warranty range, we can provide paid service.
    Invoice and warranty card is necessary when applying for maintenance service from SHOWVEN.

Warranty Card

Product Name:| | Serial No.|
---|---|---|---
Purchase Date:|
Tel:|
Address:|
Info. feedback about the problem:|
Actual problem:|
Maintenance detail:|
Service Engineer:| | Service Date:|

https://www.facebook.com/Showven-228026294663699/?modal=admin_todo_tour

Showven Technologies Co., Ltd.
Tel: +86-731-83833068
Web: www.showven.cn E-mail: [email protected]
Add: Liuyang Economic Development Zone, Changsha, 410300, Hunan Province, P.R.China

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Showven User Manuals

Related Manuals