HBLG2350E Room Air Conditioner Instruction Manual

July 29, 2024
LG

HBLG2350E Room Air Conditioner Instruction Manual

This Owner’s Manual is provided and hosted by Appliance Factory Parts.

https://www.appliancefactoryparts.com/

Shop genuine replacement parts for LG HBLG2400R

https://www.appliancefactoryparts.com/airconditioners/lg/hblg2400r.html

MODEL : LWM1836TAS, LWM1836QCG, LWN2131QAG, Y5USC24-6R,
WG2400R, LWN2432QAS, LWN2433TCS, WG1800R, M1804R,
Y5USC18-6R, LWM1836QAS, HBLG1800R, HBLG2400R,
M2403R, LWC243NSMM0, LWC243NSMM2, HBLG2350E

CAUTION
Before Servicing the unit, read the safety precautions in General SVC manual. Only for authorized service personnel.

1. PREFACE

This service manual provides various service information, including the mechanical and electrical parts, etc.
This room air conditioner was manufactured and assembled under a strict quality control system.
The refrigerant is charged at the factory. Be sure to read the safety precautions prior to servicing the unit.

1.1 SAFETY PRECAUTIONS

  1. When servicing, set the POWER of CONTROL BOARD to Off and unplug the power cord.

  2. Observe the original lead dress.
    If a short circuit is found, replace all parts which have been overheated or damaged by the short circuit.

  3. After servicing, make an insulation resistance test to prevent the customer’s exposure to shock hazards.

1.2 INSULATION RESISTANCE TEST

  1. Unplug the power cord and connect a jumper between 2 pins (black and white).
  2. The grounding conductor (green or green and yellow) is to be open.
  3. Measure the resistance value with an ohm meter between the jumpered lead and each exposed metallic part on the equipment at all Mode [except POWER OFF].
  4. The value should be over 1 MΩ.

1.3 SPECIFICATIONS

  • DB:Dry Bulb ** WB:Wet Bulb
    NOTE : Specifications are subject to minor change without notice for further improvement.

1.4 FEATURES

  • Designed for cooling only.
  • Powerful and quiet cooling.
  • Slide-in and slide-out chassis for the simple installation and service.
  • Reversible inlet grille.
  • Side air-intake, side cooled-air discharge.
  • Built in adjustable THERMISTOR.
  • Washable one-touch filter.
  • Compact size.

1.5 CONTROL LOCATIONS

VENTILATION
The ventilation lever must be in the CLOSE position in order to maintain the best cooling conditions.
When a fresh air is necessary in the room, set the ventilation lever to the OPEN position.
The damper is opened and room air is exhausted.

Copyright ©2007 LG Electronics. Inc. All right reserved.

Only for training and service purposes

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals