- ▲SAFETY CONSIDERATIONS
- ▲Description
- ▲Technical Specifications
- ▲Operation Panel
- ▲Interface
- ▲DMX Channel
- ▲E1 Pressure error explanation
- ▲ Maintenance
- ▲ Possible reason for the block of atomizer
- Warranty Instructions
- Warranty Card
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
USER MANUAL
SONICBOOM ® PLUS SMOKEJET
Showven Technologies Co., Ltd.
★Please read this manual carefully before operating this product.
★Warranty card is attached in the manual, please keep it well.
▲SAFETY CONSIDERATIONS
- Unauthorized repairs are prohibited, it may cause a serious incident
- Unauthorized repairs are prohibited, it may cause a serious incident.
- This product is not a waterproof design, please keep it dry, please do not use it when there is fog fluid leakage or wet from the rain.
- Make sure the power supply is inconsistent with the rated voltage of the equipment, and the socket must be well-grounded. Unplug and turn off the machine when not used.
- For adult use only, keep it away from fire, inflammable and explosive articles.
- Installed in a well-ventilated area, ensure at least 50cm space around the machine, cover of the nozzle is forbidden.
- If the machine fails to work, please stop the operation and unplug the machine. Check fog fluid, fuse, power connection, etc. carefully, if can’t solve the problem, please contact SHOWVEN or your local SHOWVEN partner for advice.
- Suggest use SHOWVEN original FX-S fog fluid, other fluids may lead to clogging or malfunction. Please do not add any other material such as pigment, water etc to the fuel bottle.
- To avoid fluid spill, make sure fog fluid does not exceed the related MAXIMUM fluid level line. When installing SONICBOOM in an inverted direction, the fuel bottle should be installed upward.
- In case of eye contact with fog fluid, please wash it with clean water. If the fluid is swallowed immediately look for medical advice.
▲Description
SONIC BOOM PLUS is a new generational smoke jet with a dual output design and faster and thicker effects. No generation of CO2 is environmentally friendly. Combined with SHOWVEN’s original FX-S pro quick dissipating fog fluid guarantee the fast dissipating of the smoke.
▲Technical Specifications
- MODEL: SONICBOOM® PLUS
- DIMENSION: 500×324×325mm
- WEIGHT: 28kg
- VOLTAGE: 110V-220V,50/60Hz
- FUSE: 15A/250V(220V),18A/250V(110V)
- POWER: 3000W/1800W(220V),2400W/1800W(110V)
- LED POWER: 9W×38pcs
- MAX OUTPUT DISTANCE: 10m
- MAX CONTINUOUS OUTPUT DURATION: 10s
- OUTPUT: 80000cuft/min
- FLUID CONSUMPTION RATE: 3min/L
- TANK CAPACITY: 5L
- DMX CHANNEL: 1/11/14
- CONSUMABLES: FX-S
▲Operation Panel
- Control button area
MENU: switch through the setup menu
+: Parameter up; multiplex “TIMER” (smoke output time)
-: Parameters down; multiplex “VOLUME” (smoke output start)
ENTER: confirm and save parameters (screen will blink once when save successfully); multiplex “STOP”.
NOTE: Screen will switch to the main interface automatically if not press any button in a long time.
▲Interface
-
Main interface:
First Line: DMX address, “:” blinks when there is DMX in the signal.
Second Line: shows machine core temperature and pressure. The machine is ready for operation only when both temperature and pressure values are close to 100%. -
Error information:
Error information
|
Explanation
---|---
E1 Pressure| Pressure faults, no fog fluid or pump error
E2 K temp. Sensor| Temperature sensor fault
E5 Temp Over| Circuit fault
E6 Heat Fail| Heating element damage or circuit fault or unstable voltage
3. Setting Menu:
Press “MENU” switch through the setup menu.
Options
| Range|
Explanation
---|---|---
DMX 512 Address| 1~499| Set DMX address
Power Regulation| Standard/Half Power| Setting working power for the machine
Color Optional| 0~10| LED color set when manual firing
Channel Mode| 1/11/14| DMX channel mode switch
Fog Volume| 50%/80%/100%| Manual fog volume setup
4. Advanced Menu:
Press “MENU” for 3s, enter the advanced setting interface
Item
| Value|
Explanation
---|---|---
Manual Evacuate| ON/OFF| Manual Evacuate when pressure is always insufficient
Interval Set| 1-200| Interval time
Duration Set| 1-8| Smoke output duration
Wireless Remote| ON/OFF| Wireless ON/OFF switch
Language| Chinese/English| Language switch
Manual Pump| ON/OFF| For maintenance
▲DMX Channel
1. 1 channel mode:
LED color is determined by a single channel, DMX value, and related color as
below:
Color | SMOKE OFF | LED OFF | RED | GREEN | BLUE | PINK | LED OFF |
---|---|---|---|---|---|---|---|
DMX value | 0-5 | 6-40 | 41-60 | 61-80 | 81-100 | 101-120 | |
Color | PURPLE | ORANGE | YELLOW | SKY BLUE | WHITE | Random | 236-255 |
DMX value | 121-140 | 141-160 | 161-180 | 181-200 | 201-220 | 221-235 |
2. 11 channels mode:
Channels | Function |
---|---|
Channel 1 | Firing: (0-9) OFF, ( 10-255) ON |
Channel 2 | Inner LED RED: (0-9) OFF, (10-255) LED brightness increase |
Channel 3 | Inner LED GREEN: (0-9) OFF, (10-255) LED brightness increase |
Channel 4 | Inner LED BLUE: (0-9) OFF, ( 10-255) LED brightness increase |
Channel 5 | Outer LED RED: (0-9) OFF, (10-255) LED brightness increase |
Channel 6 | Outer LED GREEN, (0-9) OFF, (10-2551) LED brightness increase |
Channel 7 | Outer LED BLUE, (0-9) OFF, (10-255) LED brightness increase |
Channel 8 | LED Random: (0-9) OFF, (10-255) LED random color, use together with |
channel 9.
Channel 9| LED color change speed: (0-9) OFF, (10-255) LED color change speed
increase
Channel 10| LED strobe: (0-9) OFF, (10-255) LED strobe increase
Channel 11| LED dimmer, (0-9) OFF, (10-255) LED brightness increase
---|---
3. 14 channels mode:
Channels | Function |
---|---|
Channel 1 | Firing: (0-9) OFF, ( 10-255) ON |
Channel 2 | Inner LED RED: (0-9) OFF, (10-255) LED brightness increase |
Channel 3 | Inner LED GREEN: (0-9) OFF, (10-255) LED brightness increase |
Channel 4 | Inner LED BLUE: (0-9) OFF, ( 10-255) LED brightness increase |
Channel 5 | Inner LED AMBER: (0-9) OFF, ( 10-255) LED brightness increase |
Channel 6 | Outer LED RED: (0-9) OFF, (10-255) LED brightness increase |
Channel 7 | Outer LED GREEN, (0-9) OFF, (10-2551) LED brightness increase |
Channel 8 | Outer LED BLUE, (0-9) OFF, (10-255) LED brightness increase |
Channel 9 | Outer LED AMBER, (0-9) OFF, (10-255) LED brightness increase |
Channel 10 | LED Random: (0-9) OFF, (10-255) LED random color |
Channel 11 | LED Random (inner LED change color): (0-9) OFF, (10-255) LED |
random color
Channel 12| LED color change speed: (0-9) OFF, (10-255) LED color change speed
increase
Channel 13| LED strobe: (0-9) OFF, (10-255) LED strobe increase
Channel 14| LED dimmer, (0-9) OFF, (10-255) LED brightness increase
NOTE: Manual function disabled when DMX connected.
▲E1 Pressure error explanation
In order to protect the pump, SONICBOOM will run a self-check program to find out whether there is fog fluid in the fuel pipe.
-
E1 pressure error activation
When there is no fog fluid in the fuel tank, the system can not reach preset pressure or even turn on for a long time. The pump will stop working, and report E1. -
Way to clear E1 error
1. Fill the fog fluid tank, then restart the machine.
2. Press “VOLUME” to reset.
3. DMX Channel 1, start a firing.
▲ Maintenance
- Use SHOWVEN original fog fluid for the best effect of SONIC BOOM. The warranty will be void if any other type of fluid is used.
- Don’t disassemble the machine from an unauthorized person, modifications to the machine are not allowed.
- Excessive dust, liquid or dirt, etc on the equipment will affect the performance of the machine and cause poor heat dissipation. Remove dust with an air compressor, vacuum or soft brush. Use a damp cloth to clean the case.
- Before storing the machine, run distilled water through the system to help avoid condensing the pump or heater.
- To keep the best status and performance of the machine, it is recommended to run the machine at least once per month.
- After continuous use of 40h (or 1-2month), please use 35% vinegar with 65% distilled water to wash the pump and pipe system by running the machine 10-15 times.
▲ Possible reason for the block of atomizer
For the healthy and best status of the machine, please do use SHOWVEN original
fog fluid.
A. Fluid spill: heat can’t effectively transmit to fog fluid, leading to
insufficient atomization of the fog fluid in the heating pipe.
Possible Reason 1: Use another type of low-quality fog fluid instead of
SHOWVEN’s original fog fluid.
Possible reason 2: Use inappropriate fog fluid. For different types of fog
fluid, the atomization temperature is different.
B. Heating aluminum pipe clog: an early symptom of heating aluminum pipe clog
is fog fluid spill caused by insufficient atomization. Use other brand fluid
or not make regular maintenance for a long time will definitely lead to pipe
clog.
C. solution for the above problem: Use SHOWVEN original fog fluid. Make
regular maintenance (every 1-2month). Use 35% vinegar with 65% distilled water
to wash the pump and pipe system by running the machine 10-15 times.
Warranty Instructions
▲Sincere thanks for your choosing our products, you will receive quality
service from us
▲The product warranty period is one year. If there are any quality problems
within 7 days after shipping out from our factory, we can exchange a brand new
same model
machine for you
▲We will offer free of charge maintenance service for machines that with
hardware malfunction (except for the instrument damage caused by human
factors) during warranty
period. Please don’t repair machine without factory permission
∗ Below situations NOT included in warranty service:
- Damage caused by improper transportation, usage, management, and maintenance, or damage caused by human factors;
- Disassemble, modify or repair products without permission;
- Damage caused by external reasons (lightning strike, power supply, etc.)
- Damage caused by improper installation or use;
For product damage not included in the warranty range, we can provide paid service.
∗ Invoice and warranty card is necessary when applying for maintenance service from SHOWVEN.
Warranty Card
Product Name:| | Serial No.|
---|---|---|---
Purchase Date:|
Tel:|
Address:|
Info. feedback about the problem:|
Actual problem:|
Maintenance detail:|
Service Engineer:| | Service Date:|
https://www.facebook.com/Showven-228026294663699/?modal=admin_todo_tour
Showven Technologies Co., Ltd.
Tel: +86-731-83833068
Web: www.showven.cn E-mail:
info@showven.cn
Add: Liuyang Economic Development Zone, Changsha, 410300, Hunan Province,
P.R.China
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>