Cleverio 40723 Intelligent Neck Massager
Product Specifications
- Power input: DC 5 V, 1 A
- Battery: Rechargeable Li-po, 3.7 V, 1500 mAh
- Battery life: 5 days (15 minutes twice a day)
- Battery, remote control: 2x CR2032
- Size: 166x144x42 mm
- Weight: 160 g
Charging
- Connect the USB charging cable in the power input of the massager and a USB power adapter (sold separately).
- Connect the power adapter to a wall outlet. The indicator lights up green when the massager is fully charged, which takes about 2 hours.
Low Battery Notification
- When the battery of the massager runs low during a massage, it emits a beeping sound three times.
Remote Control Setup
- Insert the included CR2032 batteries into the remote control.
- Open the battery cover on the back of the remote. Insert the batteries (mind the polarity) and put the cover back on.
Product Usage Instructions
- Use a damp towel to wipe your neck. For best effect, the neck should be slightly damp and free from sweat.
- Put the massager comfortably around your neck. Make sure it is in direct contact with your skin.
- Press the power button on the massager to turn it on. The power indicator flashes and waits for a signal from the remote control.
- Press the power button on the remote within one minute to start the massage with default settings.
- Adjust settings using the remote control as needed.
- To turn off the massager, press its power button. Hold the power button on the remote for 2 seconds to turn off the remote control.
FAQ
- Q: How do I clean the electrode pads?
- A: If the electrode pads are dirty, clean the surface with clean water and let them dry before use.
Overview
Massager
Remote control
Specifications
- Power input: DC 5 V, 1 A
- Battery: Rechargeable Li-po, 3.7 V, 1500 mAh
- Battery life: 5 days (15 minutes twice a day )
- Battery, remote control: 2x CR2032
- Size: 166x144x42 mm
- Weight: 160 g
Performance
- Pulse frequency: 1 Hz – 1000 Hz
- Heating temperature: 38°C ~ 48°C
- Wireless Frequency, remote: 433,92 MHz
- Transmission power: 0,09 mW (max)
Charging
- Connect the USB charging cable in the power input of the massager and a USB power adapter (sold separately).
- Connect the power adapter to a wall outlet. The indicator lights up green when the massager is fully charged, which takes about 2 hours.
- When the battery of the massager runs low during a massage, it emitts a beeping sound three times.
Remote control
- Insert the included CR2032 batteries into the remote control. Open the battery cover on the back of the remote. Insert the batteries (mind the polarity) and put the cover back on.
Use
- Use a damp towel to wipe your neck. For best effect, the neck should be slightly damp and free from sweat.
- Put the massager comfortably around your neck. Make sure it is in direct contact with your skin.
- Press the power button on the massager. The power indicator flashes and the massager awaits a signal from the remote control.
- Press the power button on the remote within one minute. The display lights up and the power indicator on the massager turns into a steady light. The massager starts massaging with default settings: intensity level 0, middle temperature and timer 15 minutes.
- Note! It can take up to 20-30 seconds before the electric pulses are felt.
- Change settings according to the instructions below. When you have finished your massage, press the power button on the massager to turn it off. Press and hold the power button on the remote control for 2 seconds to turn the remote control off.
Modes
Press the Mode button to change mode:
- Mode 1: auto-combination 1/default setting
- Mode 2: auto-combination 2
- Mode 3: scratching
- Mode 4: shiatsu
- Mode 5: rolling
- Mode 6: beating
Intensity levels
Press the + button on the remote control to increase the intensity and the – button to decrease the intensity. There are a total of 16 intensity levels. The intensity level shows on the display of the remote control. Note! Start the massage at a low intensity and increase gradually. The intensity should not be so high that the massage becomes uncomfortable.
Temperature
- Press the temperature button on the remote control to change between no heat or low, middle or high heat. The current temperature shows on the display of the remote control.
Timer
- Press the Power button on the remote control repeatedly to set the timer to 5-30 minutes (in 5-minute steps). When the massager is turned on, the timer is set to 15 minutes.
Electrode pads
- The electrode pads can be used on their own or together with the massager. Connect the electrodes to the power output of the massager. Place the pads wherever you have sore muscles. Turn the massager on and set the intensity and temperature as usual.
- Make sure the pads are clean before attaching them. If they are dirty, clean the surface with clean water and let them dry.
Recommended use
- Try to use the massager twice a day. Aim for a 15-minute session with electrodes and 15-30 minutes with just the massager.
Cleaning and maintenance
- Wipe the massager with a soft and dry cloth if it gets dirty.
- Clean the massage plates regularly with a soft, wet cloth. If it is not enough with a wet cloth, you can use a drop of medical alcohol.
- Do not store the massager in direct sunlight, high temperature or high humidity.
Safety Information
- The massager contains a rechargeable Li-po battery that cannot be replaced.
- The stainless steel contact plates contain nickel, the product should not be used by people with sensitivity or a known nickel allergy. If you experience redness, blisters or other discomfort during or after use, stop using the product immediately.
- This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they are supervised or have received instructions concerning the use of the appliance by a person responsible for their safety.
- Children should be supervised to ensure that they do not play with the appliance. Do not disassemble the massager or try to repair it yourself.
- Never use the massager or electrode pads along with other medical electronic stimulators, such as a pacemaker, artificial heart-lung which are used to maintain life, and electrocardiograph.
- Pregnant women, people with abnormally sensitive skin, heart disease, abnormal blood pressure, malignant tumour, cerebrovascular disease, acute disease or currently under doctor’s treatment, should consult a doctor before using the massager and electrode pads.
- Do not use the electrode pads near your heart, head, rashes or wounds. Do not use in high temperatures or high humidity. Do not move the massager during use.
Simplified EU Declaration of Conformity
- Kjell & Company hereby declares that this device is in compliance with the essential requirements and other relevant provisions of Directive 2014/53/EU. Full text of the EU declaration of conformity is available at www.kjell.com/40723
Contact
- www.cleverio.se
- Box 50435, Malmö, Sweden
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>