CLEVERIO AF-F100 Floor Fan with Air Filter User Manual

June 6, 2024
Cleverio

CLEVERIO AF-F100 Floor Fan with Air Filter

CLEVERIO AF-F100 Floor Fan with Air Filter

Overview

CLEVERIO AF-F100 Floor Fan with Air Filter-1

Specifications

  • Power supply    AC 100-240 V- 50/60 Hz
  • Power consumption    35W
  • Rated voltage      DC 24V
  • Battery. remote control    CR2025 (not incl.)
  • Oscillation      80±5°
  • Timer    1-8 h
  • Connection    Wifi-N (2.4 GHz)
  • Filter:    HEPA 13 filter (1000 hrs of use)
  • Replacement filter:    www.kjell.com/47082
  • Size      235 x 230 x 592 mm
  • Weight    2840 g

Use

Installation

Place the fan on a flat and stable surface and leave about 30 cm of free space from the air outlet. Avoid blocking the air inlet and place the fan away from curtains and other objects that could block the inlet.
Connect the power adapter to the fan and a wall socket. The touch display lights up and the fan goes into standby mode.

Touch display

  • Press the touch display once to start the fan. Press and hold for 2 seconds to turn it off.
  • Press the touch display while the fan is running to adjust the airflow on a scale from 1-9.
  • Press and hold the touch display for 1 second while the fan is running to start oscillation. Press and hold again to stop the rotation.

Directing the air flow

CLEVERIO AF-F100 Floor Fan with Air Filter-2

Hold the fan base with one hand and push the air outlet to your preferred angle. You can push it 15° forwards and backwards.

Remote control

CLEVERIO AF-F100 Floor Fan with Air Filter-2

Boost mode: Press the Boost button on the remote to maximise the airflow. The display shows an Hand the wind speed increases. Press the Boost button again, or the ·+’.to exit boost mode.
Night mode: When pressing the Night mode button on the remote. the display shows an L. and the airflow decreases. Press the Night mode button again. or the”+’, to exit sleep mode.
Oscillation: When pressing the Oscillation button. the fan starts to rotate 80° left to right. Press again to stop the oscillation.
Timar: Press the Timer button on the remote to set a timer for a shutdown. Press repeatedly to set a time within the next 1-8 hours. When the fan is turned off. the timer setting is cancelled.

CLEVERIO AF-F100 Floor Fan with Air Filter-4

Note: Point the remote control at the touch display to maximise the signal.
The fan may respond to other remotes and other devices may respond to this remote. This is due to overlapping frequencies and not a faulty product. To avoid this, keep the remote control away from other electrical devices during use.

Change battery
Insert one CR2025 battery into the remote according to the illustration on the right. Mind the polarity.

Mobile app

  1. Find and install the app ‘Smart life – Smart living’ on App Store or Google Play, or scan the OR code to the right.
  2. Register an account in the app to be able to proceed. Make sure your phone and the fan are connected to the same Wi-Fi network.
  3. Press and hold the touch display on the fan for 5 seconds until an F appears to activate pairing mode.
  4. Press ‘Add Device’ in the app, go to “Small Home Appliances” and choose ‘Air purifier (Wi-Fi)’.
  5. Enter the details for your network in the next step. Wait for the fan to connect. A prompt will tell you if the connection was successful. You can now control the device in your app.
  6. Turn the filter cover counter-clockwise to unlock and remove the filter.
  7. Disconnect the old filter from the cover.
  8. Attach the cover to the new filter and assemble it with the buckle.
  9. Put it back in the fan and turn it clockwise to lock it.

After the filter has been changed, press the Power button on the remote for 5 seconds to clear the filter alarm.

Cleaning and maintenance

Disconnect the power supply before any maintenance.

  • Surface
    If the surface of the fan needs cleaning, start to dust it off with a soft, dry cloth. Then wipe it gently with diluted mild detergent and wipe the moisture off with a dry cloth.

  • Air inlet and outlet
    Use a soft brush or a vacuum cleaner to remove dust from the inlet and outlet. Make sure that no dust accumulates at the inlet and outlet as this can affect the fan’s performance.

  • Remote control
    Wipe the surface of the remote gently with a soft, dry cloth. If you are not going to use the remote for a long time, please remove the battery.

  • Filter replacement
    After approximately 1 ODO hours of use, the HEPA filter needs to be replaced. The display will light up and the buzzer will sound five times when it is time.
    Change according to the following steps:

Safety information

  • For indoor use only.
  • Do not expose the fan to direct sunlight and do not use in very humid places.
  • Keep away from children.
  • Keep away from electrical devices with cooling/heating function.
  • Do not use the fan in a branch outlet together with other electrical devices.
  • Do not pull the plug out with the cable.
  • Do not use the fan with a damaged supply cord. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified personnel to avoid a hazard.
  • Disconnect the fan from the power supply if you are not going to use it for a long time.
  • Make sure the ventilations are free from dust, hair and other dirt that can affect the airflow.
  • Do not immerse the fan or any parts of it in water or other liquids.
  • Do not use an air purifier or similar next to the fan.
  • Do not use strong cleaning agents and lubricants on the appliance.

NOTE
If you encounter any problems with the manual. please go to www.kjell.com/47081 for an updated version.