Aduro 1.1 Wood Stove with Integrated Grip User Manual
- June 13, 2024
- ADURO
Table of Contents
- 1.1 Wood Stove with Integrated Grip
- General
- Installation of the stove
- Lighting the stove
- The chimney
- Maintenance and cleaning of the stove
- Accessories
- Right of complaint
- Disposal of the wood burning stove
- Aduro 9.4 wall mounting
- Aduro 9.7 mounting of heat accumulating stones
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
User Manual
Aduro 1.1 series & Aduro 9 series
Aduro 1.1, Aduro 1.1SK, Aduro 1.4, Aduro 9, Aduro 9.1, Aduro 9.3,
Aduro 9.4, Aduro 9.5, Aduro 9.6 & Aduro 9.7
13240 – Ecodesign 2022
aduro.dk/adurofire.com
1.1 Wood Stove with Integrated Grip
Congratulations on your new Aduro stove!
To get the best possible experience and benefit from your new Aduro wood
burning stove, it is important that you read the user manual thoroughly before
you install the stove and start using it. Errors or incorrect settings can
cause hazardous conditions and/or poor operation. For further information,
please go to www.adurofire.com.
Extended product warranty – free online registry
You have the opportunity to extend the warranty on your wood burning stove
from the statutory right of complaint to an extended warranty of five years.
All you need to do is register the stove at
www.adurofire.com/warranty/. The
deadline for registering is five months from the date of purchase.
Production number
The wood stove has a production number on the rating plate on the back of the
stove. For most of our stoves, the production number is also stamped on the
front page of the quick guide that is enclosed with the stove. For the
purposes of the guarantee and for other enquiries, it is important that you
are able to quote this number.
HOW TO SUCCEED WITH YOUR NEW WOOD BURNING STOVE
In Aduro’s Customer Service
Center you will find tips and tricks on how to succeed with your new Aduro
wood burning stove. Here you will have direct access to interesting content
about maintenance of your stove as well as support related information.
General
1.1 Compliance
The wood burning stove complies with the European Directive Ecodesign 2022,
the EN13240 European standard as well as the NS3058 Norwegian standard and is
thereby approved for installation and use in Europe. At the same time, the
manufacturing process is subject to external quality control. DoC (Declaration
of Conformity) can be downloaded at
www.adurofire.com/download/.
1.2 Transportation
When taking your wood burning stove home, please ensure that it travels in an
upright position. If you wish to lay it flat, it is important that you remove
all loose parts from the combustion chamber (cast iron grate, baffle plates,
and insulation tiles) and remove the ashpan. Otherwise, you can leave the
insulation tiles and the cast iron grate in the combustion chamber and then
fill it up with surplus packaging to secure the loose parts.
1.3 Technical data
Dimensions in cm:| Aduro 1.1| Aduro 1.1SK| Aduro
1.4| Aduro 9| Aduro 9.1| Aduro 9.3| Aduro
9.4| Aduro 9.5| Aduro 9.6| Aduro 9.7
---|---|---|---|---|---|---|---|---|---|---
Flue outlet, diameter| Ø15 top/rear| Ø15 top/rear| Ø15 top/rear| Ø15 top/rear|
Ø15 top/rear| Ø15 top/rear| Ø15 top/rear| Ø15 top/rear| Ø15 top| Ø15 top/rear
Outer dimensions (HxWxD)| 101.5 x 50 x 45| 104.5 x 50 x 45| 114 x 50 x 45|
95.8 x 50 x 44.7| 95.8 x 50 x 44.7| 104 x 50 x 49| 75.2 x 50 x 46| 120 x 50 x
44.7| 90 x 50 x 44.7| 120 x 50 x 45.8
Height exhaust branch above floor| 99.5| 99.5| 112.8| 92.8| 92.8| 101.2| –|
117| 87| 119.7
Distance from floor to centre of rear outlet| 88.8| 88.8| 101.4| 84| 84|
92.2| Min. 63.4 + 20.6*| 108.2| –| 137
Distance from centre of exhaust branch to rear edge of stove| 19.5|
19.5| 19.5| 19.3| 19.3| 19.3| 20.8| 19.3| 19.3| 19.3
Weight| 95 kg| 113 kg| 81 kg| 93 kg| 100 kg| 103 kg| 88 kg| 115 kg| 89 kg|
169,2 kg
| Applies to the Aduro 1.1 series| Applies to the Aduro 9 series
Fuel| Wood| Wood and wood briquettes
Max wood length| 36 cm| 39 cm
Maximum combustion amount per hour (wood)| Approx. 3.4 kg| Approx. 3.1 kg
Energy efficiency| > 78%| > 80%
Energy efficiency index| 108.7| 108.9
Applies to all the stoves:
Nominal power| 6.0 kW
Energy efficiency class| A+
Material| Sheet iron
Convection stove|
Air-wash system|
Ashpan| ****
Chimney draft| 12 Pa
Heat rating in buildings with
– Optimum insulation
– Average insulation
– Inadequate insulation| 150 m2
100 m2
60 m2
*See illustrations on adurofire.com
**See section 2.4
Installation of the stove
You may install your wood burning stove yourself – but we strongly recommend
that you consult your chimney sweep before beginning the installation. It is
important to ensure that all local rules and regulations, including ones
relating to national and European standards, are complied with when installing
this device. Your dealer can also provide you with installation advice.
Remember, it is your responsibility that rules in force are complied with.
APPLIES TO UK INSTALLATION ONLY: To comply with UK building regulations
an approved CO monitor should be installed in the same room as the appliance.
**** You may not begin to use the stove until it has been inspected and approved by your local chimney sweep.
2.1 Position of the stove / distance requirements
Distance requirements will only apply if the wood burning stove is to be
placed close to flammable materials:
Distance to flammable material (cm)| To the sides (A)|
Behind the stove (B)| Distance to furniture (C)| Corner
position (D)| Above the stove
---|---|---|---|---|---
Aduro 1.1| 40| 7.5| 100| 10| 50
Aduro 1.1SK| 40| 7.5| 100| 10| 50
Aduro 1.4| 40| 7.5| 100| 10| 50
Aduro 9| 70| 20| 80| –| 50
Aduro 9.1| 40| 7.5| 100| 10| 50
Aduro 9.3| 70| 7.5| 100| –| 50
Aduro 9.4| 70| 7.5| 100| –| 50
Aduro 9.5| 70| 7.5| 100| –| 50
Aduro 9.6| 70| 20| 80| –| 50
Aduro 9.7| 70| 7.5| 100| –| 50
If the stove is positioned against a brick wall or other non-flammable
material, there are no minimum distance requirements. To facilitate cleaning
and for the best use of the convection air, we recommend that you keep a
distance of approximately 5-10 cm to the wall.
If the wood burning stove is to be placed on a flammable material (or above
flammable material for Aduro 9.4) such as a wooden floor or carpet, it must be
placed on a non-flammable floor hearth. The floor hearth should extend for at
least 30 cm in front of the stove and 15 cm on each side measured from the
opening of the combustion chamber.
**** The wood burning stove must be installed on a floor with the adequate loadbearing capacity. If the existing construction does not meet this requirement, appropriate adaptation measures must be taken (e.g., a load- distributing plate).
2.2 Pipe connection
Please ensure that all local rules and regulations are complied with,
including CE marking of the flue pipe.
Additionally, distance requirements to flammable material for the pipe must be
respected.
A flue pipe with an internal diameter of 150 mm should be used for all Aduro
stoves.
Aduro 1.1, 1.1SK, 1.4,
9, 9.1, 9.3, 9.4 & 9.5| The stove leaves the factory with the flue outlet
mounted on the top. If you require the flue outlet on the back, “break” off
the cover plate / plates positioned at the top of the back of the stove.
Exchange the exhaust connector (from the top outlet) with the cover plate from
the rear outlet. Mount the cover plate from the rear outlet to the top outlet.
The top outlet is finished with the plate that lies in the ashpan. You may
benefit from putting a slim gasket between the flue on the stove and the flue
pipe. Specific for Aduro 1.1SK: If you choose to use the smoke outlet at the
back of the stove, it is important to mount the pipes before the stones are
mounted. Remember to place the cover plate correctly. See section 2.5.
---|---
Aduro 9.6| The stove leaves the factory with the flue outlet mounted on the
top.
Aduro 9.7| The stove leaves the factory with the flue outlet mounted on the
top. If you require the flue outlet on the back, use a 90° flue pipe. Use a
standard flue pipe (see illustration below). The top outlet is finished with
the plate that lies in the ashpan. You may benefit from putting a slim gasket
between the flue on the stove and the flue pipe.
2.3 Connection to a brick chimney
If the stove is being connected to a brick chimney you should use the rear
outlet (this does not apply to Aduro 9.6 & 9.7) or a curved flue pipe via the
top outlet (or through the room above the combustion chamber for Aduro 9.7).
After measuring, a hole is made in the chimney in which the pipe sleeve is
placed, and stove mortar is used to seal it in place. The stove is placed in
position and the flue pipe is put in place. A thin gasket is placed between
the flue pipe and the pipe sleeve to seal the joints The flue pipe should
protrude into the pipe sleeve but must not block the opening in the chimney
(see the illustration below). You may benefit from putting a slim gasket
between the flue outlet on the stove and the flue pipe.
The stove can be connected to a chimney to which other heat sources are connected.
Applies to Aduro 9.4:
Aduro 9.4 must be mounted onto brick chimneys including insulated chimney
elements. The stove cannot be mounted directly to a brick chimney without
insulated chimney elements or directly onto insulated chimney elements as
shown below:
2.4 Attachment / hanging of Aduro 9.4
Aduro 9.4 must be installed on a non-flammable wall. The stove is being
delivered with a wall bracket which must be properly fastened to the wall
before mounting the stove (find instructions for mounting the bracket at the
back of this user manual). You may consult your normal supplier of building
materials about suitable attachment materials for the stove/wall before the
mounting. ONLY USE FIXING MATERIALS WHICH CANNOT MELT. If you have any doubts
about the requirements, please consult your chimney sweep who will inspect the
stove.
When the wall fittings are mounted and fastened correctly, the stove can be
pushed into place. Thereafter, the stove must be fastened to the wall fittings
with a screw under the bottom. The stove may also be adjusted at the top of
the wall fittings (see illustration).
**** The lower edge of the stove must be minimum 20.6 cm above the floor.
2.5 Mounting of soapstone on Aduro 1.1SK
Aduro 1.1SK is mounted with a stone cover. To avoid damages, it is important
to follow the instructions below when mounting the stone cover.
The top stone lies on top of the wood burning stove at delivery and is lifted
off before placing the stove. In the drawer lies 6 side stones, 12 dowels, and
6 metal brackets, which should also be removed before placing the stove.
When the stove is placed at its final position, the stone cover can be
mounted. Please follow the instructions below. NB! Mounting of the smoke
outlet at the back of the stove should be done before mounting the stone
cover.
Mounting the stone cover:
- Carefully place the first side stone on the dowels on the bottom plate and place dowels in the two holes at the top of the side stone. Then fix the stones by fixing the dowels to the body of the stove using the metal brackets (see illustration).
- Repeat step 1 with the middle and last stone.
- Repeat step 1-2 on the opposite side.
- Place the top stone on the dowels.
- If the stove is mounted with the flue outlet at to the back of the stove, then place the 3 adjustable “holders” between the inner stove and the stone top in order to make sure that the small top plate can be placed correctly and have the same height as the stone top plate.
2.6 Mounting of heat accumulating stones in Aduro 9.7
Aduro 9.7 comes with heat accumulating stones. Find instructions for mounting
the stones at the back of this user manual.
Lighting the stove
Important safety information:
- The wood burning stove will become warm during use and therefore it should be treated with all necessary caution.
- Never keep easily combustible fluids such as petrol in the vicinity of the wood burning stove.
- Never use easily combustible fluids to light the fire in the wood burning stove.
- When lighting a fire and adding new wood logs, it is important to get the fire burning fast. If the fire does not start quickly and wood only smoulders, it can cause strong smoke formation and in worst case cause an explosive ignition of the flue gasses, which can damage the stove.
- Never empty the ashpan when the wood burning stove is warm. Embers may still be found in the ashpan for up to 24 hours after the fire has gone out. Please wait to empty the ashpan until you are sure that there are no embers in the ash.
- The door should be kept closed while the wood burning stove is in use. While lighting the fire, the door can stand ajar for the first few minutes.
- When putting logs in a hot stove, you must always open the primary air intake and make sure that the wood ignites within 2-3 minutes. If the wood does not ignite, add some ignition products, and ignite them manually. Please make sure that the flames are burning steadily for the first 10 minutes before you leave the stove.
- In the event of a chimney fire: Close all the dampers on the wood burning stove and call the firefighting service.
3.1 Air damper
The stove is equipped with air dampers for regulation of the primary and
secondary air supply. The primary air is used at the beginning to get the fire
going, and the secondary air keeps the fire burning evenly. The tertiary air
ensures that flue gasses are burned and is not adjustable. You must always add
secondary and tertiary air, while firing the stove. The illustration below
shows the stove with the air dampers indicated:
3.1.1 Primary damper
When you add new logs, the primary damper should be opened until the fire is
burning properly. In order to utilise the fuel to the fullest extent, the
embers should have burnt for so long that it is necessary to open the primary
damper for approx. 2 minutes to get the logs burning. However, it is important
to fire at a certain time so that the flames do not go out during the closing
time for the Aduro-tronic.
In order to reduce the risk of ash falling from the stove when the door is
opened to add more fuel, it is a good idea to open the primary damper for
approx. 1 minute before the door is opened. This increases the draft through
the stove.
3.1.2 Secondary damper
The secondary damper behind the door allows you to adjust the wood burning
stove to the chimney draft and the required heat output. Turning the damper to
the left decreases the air supply and turning to the right increases the air
supply. In normal circumstances, the wood burning stove should be working
with this damper open between 60 % and 100 %. You should never close the air
supply so far that the flames go out.
There should always be visible flames in order to achieve a clean and
efficient combustion. A too low supply of air can lead to bad combustion, high
emissions, and a low efficiency. The air-wash system that minimises soot on
the front glass is also adjusted by this damper.
If you want to fire in the stove with the lowest possible effect – around 3 kW
– you must close the secondary damper almost completely approx. 45 minutes
after stoking. At this point there are only few flames, and the stove can burn
clean by using the tertiary air from the back of the combustion chamber.
Aduro Key: The stove comes with an Aduro-key which provides easier
control of the secondary damper. The key is fitted onto the control handle in
order to easily adjust the airflow from side to side. See illustration.
3.1.3 Secondary damper at side glass (do not apply to the Aduro 1.1 series,
9.1 & 9.6)
The stove is equipped with an air-wash system by the side glasses, which can
be regulated individually. The air-wash on the side glasses can be opened and
closed by moving the dampers from side to side. You can use the Aduro key for
this purpose.
3.2 Aduro-tronic
Aduro wood burning stoves are equipped with the patented Aduro-tronic
automatic as a standard. Adurotronic is a manually operated mechanical start-
up device, which works without the use of electricity. It automatically
regulates the combustion air and thus
secures an efficient combustion. For further information, go to
www.adurofire.com.
3.2.1 How to operate Aduro-tronic
When lighting
When lighting a fire in the stove, the maximum amount of primary air will be
needed to light the fire. For that reason, the primary damper can be kept
“forcibly open”. This is done by pulling the primary damper out as far as
possible and then fixing it with the Aduro Key (see illustration). When the
stove is warm, and a layer of embers has been created on the bottom of the
combustion chamber, the Aduro-tronic can be set to the automatic position,
i.e. the Aduro key can be removed. Alternatively, you can leave the door ajar
the first few minutes during the ignition phase (without the key).
When stoking
You activate the automatic by pulling out the damper every time new firewood
is added. The Aduro-tronic automatic will then close the damper gradually
after the pre-programmed time. It is important that there are still clear
flames after the damper is closed.
Regulation of the Aduro-tronic automatic
The automatic is pre-set to close the primary air intake within 6 minutes.
This setting has been used during testing at the Danish Technological
Institute using a standard chimney and ‘standard’ sized logs (approx. 30 cm
long and 10×10 cm thick) with maximum moisture content of 18%. In practice,
such circumstances can differ, which is why the Aduro-tronic automatic can be
adjusted to your circumstances. If you want a slower intake of primary air
(e.g. for a lower chimney draft, larger sized wood, or for longer intervals
between stoking), adjust the screw on the front of the control bracket using a
small allen key. If the screw is turned to the right, the closing time is
increased, and if turned to the left, the closing time is reduced.
3.3 Ventilation / fresh air supply
In order for the wood burning stove to function at optimum efficiency, air is
needed for the combustion process. There must be sufficient fresh air coming
into the room where the wood burning stove is placed. In very well-insulated
houses or houses with powerful cooker hoods and/or air conditioning systems, a
vacuum can be created around the wood burning stove, leading to smoke leakage
and poor combustion. In these circumstances, it might be necessary to open a
window to provide air for the combustion and to equalize the vacuum.
Alternatively, you could place an air vent in the room where the wood burning
stove is placed. The amount of air needed for the combustion is 25 m3/h.
3.4 How should I use my wood burning stove?
The wood burning stove is intended for intermittent combustion. This means
that each stoking should burn down to embers before new logs are added. Always
respect the MAX-load line which marks the limit for the amount of wood.
You can regulate the effect/heat output with the fuel. Burning small logs
provides more powerful combustion than burning large logs. The ideal heat
output is reached by burning approx. 1.5 kg wood per hour.
If you experience problems lighting the fire or the fire dies after a short time, it can be due to the following reasons:
- The firewood is not dry enough. The firewood should have a moisture content of max. 18%.
- There is a negative pressure in the house. See section 3.3.
- The smoke outlet from the outside may be blocked from sooth. This can occur after chimney sweeping. Control the smoke outlet.
- The used amount of wood may have been too small. This results in a too little and too cold layer of embers which cannot light the new wood.
**** If you overload the wood burning stove and burn more than the recommended amount of wood per hour (see section 1.3), there is a risk that the surface of the stove will become discoloured and eventually fall off. The stove can be resurfaced.
3.5 The first time a fire is lit
The wood burning stove is packed in recycling packaging. The wood from the
packaging can be sawed into smaller pieces and used the first few times a fire
is lit. The plastic packaging must be disposed according to national rules
regarding disposal of waste.
During transportation, it may happen that the baffle plate in steel falls out
of place. Therefore, before using the stove, please make sure that the baffle
plate is properly placed (on the hooks or fastened to the bolts depending on
the model) for optimum combustion and for preventing soot on the glass.
The first few times the wood burning stove is used, there may be some smoke
and unpleasant odours from the wood burning stove, which is normal. This is
caused by the heat-resistant paint hardening. Make sure there is sufficient
ventilation during this stage. It is also important not to let the fire burn
too fiercely the first 23 times, so that the steel has time to expand slowly.
You should also be aware that the stove may make some clicking sounds as it
heats up and cools down – like pouring boiling water into a sink. These are
caused by the great differences in temperature to which the materials are
being exposed.
**** During the first firing, which should be carried out using approximately 1 kg of wood, the door must be left slightly open and must not be closed until the stove is cold. This is to prevent the gaskets from sticking to the stove.
3.6 Lighting a fire in the wood burning stove
How you light a fire is very important for a quick and efficient ignition
phase. Follow these instructions when lighting the stove:
- Open the primary damper under the door and the secondary damper behind the door.
- Place a wood log crosswise in the combustion chamber and put 2 firelighters close to the log. Light the firelighters and quickly put a new log close to the firelighters and several small logs at an angle above it. Air must be able to reach the firelighters, but the logs should be touching to “warm” each other.
- When there are distinct, visible flames and the fire is burning well, close the primary damper under the door.
**** The control handles will get warm when the wood burning stove is in use.
Please use the glove provided when you operate the wood burning stove.
3.7 Recommended fuels
We recommend the use of split hardwood that has been stored outdoors under
cover for at least 1 year.
Wood that has been stored indoors has a tendency to become too dry and will
burn too quickly. We recommend that you fell the wood during the winter when a
lot of the moisture in the wood will have been drawn down into the roots. In
order to achieve optimum combustion, the wood’s moisture level should not
exceed 18%, which roughly corresponds to storing the wood outdoors under a
cover for one year. The moisture level of the wood can be measured using a
wood moisture meter or by applying dishwashing liquid to one end of the log
and blowing air in the other end. If the wood is dry enough, soap bubbles will
appear.
The wood should be chopped into logs with a diameter of approx. 10 cm and a
length of max. 36 cm (Aduro 1.1 series) / max. 39 cm (Aduro 9 series). Firing
with wet fuel will reduce the energy efficiency and increase the particle
emission.
Burning varnished wood, impregnated wood, chipboard, paper, and other waste is
strictly forbidden. Burning these materials will damage the environment, the
wood burning stove, and your own health. Fossil fuels must not be used.
The chimney
The stove is tested in accordance with current standards, where a smoke exhauster secures a constant chimney draft of 10-14 Pascal (Pa). However, with a natural draft (without a smoke exhauster installed) the chimney draft will increase to 18-25 Pa at optimum conditions. There are many factors that affect the chimney draft, including the outside temperature, wind strength, and surrounding buildings. There are no requirements with respect to specific chimney heights, but a chimney must be tall enough to provide a good draft. If the recommended chimney draft is not achieved, there may occur problems with smoke coming out of the door during firing.
Calculation of chimney when firing with wood
Data| Aduro 1.1 series| Aduro 9 series
Flue temperature at [20°C]| 289| 245
Chimney draft at testing power [mbar]/[Pa]| 0.12/12| 0.12 / 12
Flue gas mass flow [g/s]| 4.42| 5.7
4.1 Inadequate draft in the chimney
If you experience poor draft in the stove after the installation, please make
sure that there is nothing in the chimney to restrict the smoke and that no
nearby buildings or trees affect the winds around the chimney.
If the chimney is too short, leaks, or is inadequately insulated, there may be
problems with the chimney draft (let the chimney sweep assess this). The draft
should be sufficient during the ignition phase when the stove/chimney is cold
to provide a clean combustion and prevent smoke leakage. Therefore, we
recommend a chimney draft around 5 Pa in the ignition phase.
Once the ignition is a success, and the smoke temperature is rising, it is
important that the chimney draft reaches a stable area around 18-25 Pa in
operation (1 hour after ignition) when the chimney/stove is hot.
The draft in the area of 18-25 Pa when the stove is hot is essential in order
to achieve an optimum and clean combustion. Therefore, we recommend that you
measure the chimney draft when the chimney is cold and when it is hot after 1
hour in operation.
In practice, the chimney draft will differ – especially in cold condition.
Therefore, the best indication of the chimney draft is to measure the draft
when it is hot. If the chimney sweep judges the draft to be sufficient, but
you still have problems lighting a fire, try extending the ignition phase by
using more thin pieces of kindling and 1-2 firelighters, so that the chimney
gets thoroughly warm. The chimney will not draw at optimum effect until it is
warm. When a layer of embers has been formed, add 2-3 dry logs.
If it is impossible to establish a sufficient natural chimney draft, you can
mount a smoke exhauster, e.g. Aduro
DraftOptimizer.
4.2 Chimney and smoke
If you experience smoke coming out of the stove or the start section of the
smoke pipe, it could be due to certain weather conditions. On stormy or cold
winter days, or if the chimney has not been used in a while, a cold plug can
be created in the chimney, meaning the natural draft will be at its minimum.
If the chimney is cold and cold plugs are created, you may experience smoke
leaks during the ignition phase. In this situation there can be more smoke
than usually in the combustion chamber, and some of it might leak out of the
stove. Therefore, if you have a cold chimney that has not been used for a
while, we recommend that you use some wood sticks to heat the chimney and
eliminate the cold plug.
Maintenance and cleaning of the stove
**** All maintenance and cleaning of the stove should be carried out when the stove is cold.
Combustion chamber
The fireproof tiles in the combustion chamber eventually wear out and should
be replaced when the cracks are more than 0.5 cm wide. The durability of the
tiles depends on how often and how intensively the stove is used. You can
change the tiles yourself. They are available as a ready-to-use set. You can
buy the sets at www.aduroshop.com.
Glass
Wet wood, unsatisfactory chimney draft, and wrong use of the stove can leave
soot stains on the glass panes. It can easily be removed using a damp cloth
that you dip in cold ash and rub on the sooty glass. Special cleaning agents
are also available to remove soot from glass, e.g. the Aduro Easy Clean
pad. The pad neither scratches nor damages the glass and is for multiple
usage. Water or other cleaning agents are not necessary.
It is common maintenance to tighten the glass fittings and the hinges shortly
after the stove has been installed.
Gaskets
Check if the gaskets around glass and door are properly placed. Over time, the
gaskets will wear out and should therefore be checked regularly. If leakages
appear, they should be replaced, as it is essential that the stove is tight.
Adjusting the door
Adjusting the door and the closing mechanism is a necessary part of the
maintenance of the stove, which you can easily do yourself. If the door hangs
on one side, feels sluggish to close or does not close properly, you should
adjust and tighten the hinges and fittings around the door.
Ashes
Empty the ashpan before it gets completely full but always leave a layer of
ashes in the combustion chamber because it insulates and makes it easier to
light a fire next time.
Cleaning the stove
The stove’s surface will stay at its best just by being vacuumed with a small,
soft mouthpiece or dusted with a soft, dry cloth. Do not use spirit or other
solvents, as they will remove the paint.
**** Do not clean the stove with water. If the stove is exposed to moisture, the stove may develop rust.
The inside of the stove and the flue pipe can be cleaned through the door or alternatively through the cleaning aperture in the flue pipe/chimney. The upper fireproof tile (the baffle plate) can be removed. To allow free access to the top of the stove and the flue pipe, also remove the baffle plate in steel. The flue pipe can be removed from the stove and cleaned. Cleaning of the inside of the stove and the flue pipe should be undertaken at least once a year, or more frequently if necessary, depending on how often the stove is used. This work can also be carried out by the chimney sweep or your local Aduro GO partner.
Repairing the surface
The stove is painted with a heat resistant paint that can withstand
temperatures up to 500 degrees. If the surface of the stove gets scratched or
worn, it can easily be renewed using this type of paint. The paint is
available in black metallic at www.aduroshop.com/aduro-spray-black-metallic-
53262a.
Cleaning of soapstone on Aduro 1.1SK
You can clean the soapstone by wiping it with a soft, moist cloth or by using
dishwashing liquids.
Spare parts and unauthorized alterations
You may only use original spare parts for your stove. All forms of
unauthorized alterations to the stove are strictly forbidden, as the stove
will no longer comply with the approved specifications. At
www.aduroshop.com you can buy original spare parts
for your stove.
Bauart safety spring
All Aduro stoves are fitted with a “Bauart” safety spring. The mechanism
ensures that the door of the stove closes automatically. The “Bauart” spring
is a law requirement in some European markets, so please check your local
regulations if you wish to permanently remove the spring.
If you wish to remove the spring, here is how to do it:
- Use a pair of pliers to pry the upper hook of the Bauart spring out of the hole in the stove’s door. Watch this video.
- Please note that the spring is in tension when the door opens, so make sure to protect yourself during removal. We recommend that you use protective gloves.
- For optimum combustion, we recommend that you close the hole in the stove with a self-tapping screw, sealing compound, or ceramic glue.
Accessories
For Aduro stoves we offer a wide range of accessories to fulfil the experience: Companion sets, firewood baskets, fireplace grid, floor hearths, flue pipes, and kindling products. For further information, go to www.adurofire.com/accessories/.
Right of complaint
The right to complain applies in accordance with the sales act in the country
where the stove was purchased.
The dated receipt will be sufficient proof.
The right of complaint does not cover:
- Damages resulting from incorrect installation and use of the stove, overheating, and wrong or missing maintenance of the stove etc.
- Consumable service parts (glass, gaskets, insulation tiles, slides, painted surfaces, cast iron grate etc.), which are subject to normal wear and tear. You can buy these parts in our online shop www.aduroshop.com.
- Damages caused by electrical surcharge, (condensation) water in and around the chimney, too much or too little draft in the chimney and missing maintenance/cleaning of the chimney/flue pipe/installation.
- Damages to the stove caused by external influences, or damages caused by the stove on other objects. Read more at www.adurofire.com/warranty
Disposal of the wood burning stove
When disposing your wood burning stove, metal, vermiculite, and ceramic glass
must be sorted separately.
Dispose hereafter the materials according to the regulations at your nearest
recycling depot.
Aduro 9.4 wall mounting
- The wall bracket:
- Place the stove on the lower rails of the bracket and push the stove in place:
- Secure the stove in the “lock” position at the top and with the screw under the bottom:
Aduro 9.7 mounting of heat accumulating stones
-
Remove the stones from the storage space under the combustion chamber:
-
Dismount the front plate above the door:
-
Place the heat accumulating stones. Choose option A or B:
A. If you use the top flue outlet: B. If you use the rear flue outlet: -
Place the stones and mount the front plate again:
References
- Brændeovn | Find de bedste brændeovne på Aduro.dk
- Home
- Aduro | Poêles à bois scandinaves design et haute technologie
- Home
- Vedovn fra Aduro | Svanemerkede dansk vedovner
- Wood stove | Find the best wood-burning stoves at Adurofire.com
- Kaminofen kaufen | Schwedenofen | Dänische Kaminöfen auf adurofire.de
- Braskamin från Aduro | Svanenmärkta braskaminer med automatik
- Brændeovn | Find de bedste brændeovne på Aduro.dk
- Brændeovn | Find de bedste brændeovne på Aduro.dk
- Download | Nyeste kataloger | Find manualen til din ovn
- Garanti
- Tilbehør
- Home
- Home
- Accesorios
- Descarga de documentos
- Garantía
- Aduro | Poêles à bois scandinaves design et haute technologie
- Aduro | Poêles à bois scandinaves design et haute technologie
- Garantie défauts poêles | Aduro
- Télécharger | Catalogue | Trouver le manuel pour votre poêle
- Home
- Home
- Accessori
- Sezione Download
- Garanzia
- Garanzia
- Vedovn fra Aduro | Svanemerkede dansk vedovner
- Vedovn fra Aduro | Svanemerkede dansk vedovner
- Download | Nyeste kataloger | Finn bruksanvisningen til din ovn
- Garanti
- Tilbehør
- Wood stove | Find the best wood-burning stoves at Adurofire.com
- Wood stove | Find the best wood-burning stoves at Adurofire.com
Read User Manual Online (PDF format)