SECURITY BRANDS 16-X2 Ascent X2 Cellular Multi-Tenant Entry System Installation Guide
- September 9, 2024
- SECURITY BRANDS
Table of Contents
- 16-X2 Ascent X2 Cellular Multi-Tenant Entry System
- Specifications:
- Product Usage Instructions:
- Step 1: Unpack and Check Items
- Step 2: Activation
- Step 3: Mounting
- Step 4: Connecting Wires
- Step 5: Power Supply
- Q: What should I do if the unit is not working after
- Q: Can I use alternate mounting methods?
16-X2 Ascent X2 Cellular Multi-Tenant Entry System
“`html
Specifications:
- Model: 16-X2
- Power Supply: 12-V AC/DC Adapter
- Components included: Key, Carriage Bolt (4x), Hex Nut (4x),
Screwdriver
Product Usage Instructions:
Step 1: Unpack and Check Items
Ensure all items are present as shown in the manual.
Step 2: Activation
Complete the activation process before using the unit. Refer to
the Activation Guide included.
Step 3: Mounting
Unlock and open the faceplate for mounting. Use the recommended
gooseneck pedestal and provided hardware. Ensure proper
installation to avoid signal issues.
Step 4: Connecting Wires
Feed wires through the back of the unit and connect as shown
with the included screwdriver. Follow the gate/door opener manual
for accurate connections.
Step 5: Power Supply
When connecting the power supply, match positive to positive and
negative to negative to prevent damage. Use 18-gauge stranded wire
for connections.
FAQ:
Q: What should I do if the unit is not working after
installation?
A: Ensure the activation process is completed as mentioned in
the manual. If issues persist, contact Summit Control for
assistance.
Q: Can I use alternate mounting methods?
A: Alternate mounting is possible, but ensure to purchase and
install the 4G LTE Antenna Extension Kit to maintain signal
strength.
“`
Install GUIDE
1
Unpack box and make sure you have all items shown here.
1 of 2
Model 16-X2
Ascent Unit
12-V AC/DC Adapter
Key
Carriage Bolt
( 4x )
Hex Nut
( 4x )
Screwdriver
r IMPORTANT r
This Ascent unit WILL NOT WORK until the activation process is COMPLETE!
See the included Activation Guide to get this unit activated.
If you need help or have any questions, please contact Summit Control at
972-474-6422.
WARNING
AUTOMATIC GATES CAN CAUSE SERIOUS INJURY OR DEATH!
ALWAYS CHECK THAT THE GATE PATH IS CLEAR BEFORE OPERATING!
REVERSING OR OTHER SAFETY DEVICES SHOULD ALWAYS BE USED!
2
Unlock and open unit faceplate for mounting, wiring, and setup.
r IMPORTANT r
We recommend mounting the unit on a gooseneck pedestal using the included
mounting hardware.
If using alternate mounting, the 4G LTE Antenna Extension Kit
(Model 16-ANTX-1) should be purchased and installed.
Failure to do so may result in NO SIGNAL!
CAUTION
Use all four carriage bolts when mounting the unit to a pedestal.
Leave the “hockey puck” antenna in place even if using an antenna extension.
Seal all openings created in the enclosure.
Failure to follow these instructions can damage the unit!
3
Mount unit to pedestal using included mounting hardware.
(This step may be completed later.)
What’s what?
All important components labeled
Power Terminals For wiring to included power
supply. See Page 2.
Relay Terminals For wiring to gate operator or
door opener. See Page 2. Relay status is indicated by
adjacent LED.
Wiegand Terminals For wiring to Wiegand devices.
See Page 2.
Digital Input Terminals For connecting accessory devices.
Scan QR code on next page for wiring instructions.
Unit shown with faceplate fully open. Internal wiring not shown for clarity.
STOP
This is a cellular accessory for a gate or door. An uninterrupted cellular
connection CANNOT BE GUARANTEED!
An emergency egress or primary entry mechanism SHOULD ALWAYS BE USED!
(transmitter, fire box, mechanical release)
Consult with your dealer, distributor, and/or system designer for more
information.
Cellular Antenna Jacks Jack marked with dashed line is backup jack and not
used.
WiFi/Bluetooth Antenna Jack
Power Indicator LED
Directory Insert Fill included insert out by hand to get started right away,
or scan the QR code on next page for printable templates.
Call 972-474-6422 Email
support@summitcontrol.com
We are available MonFri / 8am5pm Central
Flip page to continue…
Install GUIDE
4 Connect wires
Feed wires through back of unit, and connect as shown using included
screwdriver.
Consult gate/door opener manual for exact connections. Terminals vary widely
across manufacturers and models.
Additional wiring diagrams can be found below and online.
2 of 2
Model 16-X2
CAUTION
When connecting the power supply, remember to connect positive to positive and negative to negative to avoid damage.
Reversing polarity can damage the unit and void the warranty!
We recommend using 18-gauge stranded wire for all connections.
Ascent terminals can be unplugged to make wire connections easier.
Relay B can be connected in same manner.
N/C COM N/O N/C COM N/O NEG. () POS. (+) POWER (+) POWER () COM RADIO FREE EXIT COM COM REVERSE LOOP COM OPEN STOP CLOSE
RELAY B
RELAY A
POWER
1224 VDC
Ascent Power and Relay Terminals
12-V AC/DC Adapter (included)
The GROUND terminal is optional unless required by local code(s). If using,
please connect to earth ground or equivalent.
If plugging into duplex outlet, remove screw from outlet plate, and secure
with included screw.
Gate Operator / Door Opener
STOP
Before going forward, double check all wiring and make sure the unit has
power!
A wiring diagram for connecting to Wiegand devices can be found below.
For connecting accessories not mentioned, please scan the QR code on this
page.
Make sure the gate path is clear before completing Step 5!
5
Key in temporary code 2012 on
keypad and confirm gate opens. If it
does, close and lock unit faceplate.
2012
Adding codes is done in online dashboard and CANNOT be done using keypad on unit!
N
INSTALLATION COMPLETE!
Now follow the Activation Guide to create an account and begin using Ascent.
A Wiegand Device
Feed wires through back of unit, and connect as shown using included
screwdriver.
These terminals are used to connect a Wiegand device such as a card reader or
Wiegand keypad.
Either set of Wiegand terminals can be used for wiring and then configured in
the online dashboard.
CAUTION
Disconnect power to the Ascent unit before connecting Wiegand devices.
Failure to disconnect power can damage the unit!
Need More?
Use the QR code below for printable directory insert templates and more
resources, including how-to videos and additional wiring diagrams for
connecting accessory devices.
Ascent terminals can be unplugged to make wire connections easier.
DATA 0 DATA 1 GND +12V LED 1 LED 2 DATA 0 DATA 1 GND +12V LED 1 LED 2 LED 1 LED 2 DATA 1 DATA 0 GND +12V
WIEGAND 1
WIEGAND 2
Ascent Wiegand Terminals
© 2024 Security Brands, Inc. All rights reserved.
WIEGAND INPUTS
Wiegand Device
IG-16X2-EN-US Rev. A (7/2024)
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>