SECURITY BRANDS 19-100E Advantage DKLP Economy Keypad Post Mount User Guide
- June 6, 2024
- SECURITY BRANDS
Table of Contents
SECURITY BRANDS 19-100E Advantage DKLP Economy Keypad Post Mount
QUICKSTART GUIDE
START HERE
What’s what?
Important components labeled
CAUTION!
Double check your wires! You must wire from positive on keypad unit to
positive on your power source and negative on keypad unit to negative on your
power source.
Reverse polarity can damage keypad unit!
WARNING!
- AUTOMATIC GATES CAN CAUSE SERIOUS INJURY OR DEATH!
- ALWAYS CHECK that the GATE PATH IS CLEAR BEFORE OPERATING!
- REVERSING or other SAFETY DEVICES SHOULD ALWAYS BE USED!
Make the connections
Additional Programming
Things to Know
*The Star Key ()**
The star key deletes your current entry.
If you happen to make a mistake keying in a code, simply press the star key to
delete the entire entry and start over.
The Pound Key (#)
The pound key is good for one thing and one thing only: exiting Programming
Mode. Whenever you’re in Programming Mode, simply press the pound key to get
out.
Master Reset Procedure
If for some reason the Master Code and/or Latch Code is forgotten, a reset
procedure is available to remedy the situation.
This procedure can be found on Page 4 of this guide.
NOTE: Green arrow indicates “good” tone on keypad. Always wait for good tone before moving on.
Programming Sub Modes
- Add Access Code(s)
- Delete All Codes
- Delete Code(s)
- Change Master Code
- Set Latch Code
- Set Relay Output Time
Master Reset Procedure
This procedure is used if the Master Code is unknown, or if the Latch Code is
unknown and the unit is in Latch Mode. All other codes will be retained after
completing this procedure.
NOTE: If an error is made during these procedures, an “error” tone will
sound, and you must start again from the beginning.
-
Step 1 – Open front panel on unit.
-
Step 2 – Disconnect power.
Remove one power wire from screw terminal on circuit board by unscrewing and removing. -
Step 3 – Press and hold Reset Button; reconnect power; then release Reset Button. Insert removed power wire back into screw terminal and screw down to secure. Unit will sound one (1) tone. Release Reset Button after you hear tone.
-
Step 4 – Close front panel on unit.
The Master Code is now reset to default (1251).
NEED HELP
Call 972-474-6390
Email
techsupport@securitybrandsinc.com
We are available Mon–Fri / 8am–5pm Central
Read User Manual Online (PDF format)