SECURITY BRANDS 19-100E Advantage DKLP Economy Keypad Post Mount User Guide

June 6, 2024
SECURITY BRANDS

SECURITY BRANDS 19-100E Advantage DKLP Economy Keypad Post Mount

SECURITY-BRANDS-19-100E-Advantage-DKLP-Economy-Keypad-Post-Mount-
PRODUCT

QUICKSTART GUIDE

START HERE

SECURITY-BRANDS-19-100E-Advantage-DKLP-Economy-Keypad-Post-Mount-
fig2

What’s what?

Important components labeled

SECURITY-BRANDS-19-100E-Advantage-DKLP-Economy-Keypad-Post-Mount-
fig5

CAUTION!
Double check your wires! You must wire from positive on keypad unit to positive on your power source and negative on keypad unit to negative on your power source.
Reverse polarity can damage keypad unit!

WARNING!

  • AUTOMATIC GATES CAN CAUSE SERIOUS INJURY OR DEATH!
  • ALWAYS CHECK that the GATE PATH IS CLEAR BEFORE OPERATING!
  • REVERSING or other SAFETY DEVICES SHOULD ALWAYS BE USED!

 Make the connections

SECURITY-BRANDS-19-100E-Advantage-DKLP-Economy-Keypad-Post-Mount-
fig6 SECURITY-BRANDS-19-100E-
Advantage-DKLP-Economy-Keypad-Post-Mount-fig7 SECURITY-BRANDS-19-100E-Advantage-DKLP-Economy-Keypad-
Post-Mount-fig8

SECURITY-BRANDS-19-100E-Advantage-DKLP-Economy-Keypad-Post-Mount-
fig9

Additional Programming

SECURITY-BRANDS-19-100E-Advantage-DKLP-Economy-Keypad-Post-Mount-
fig12

SECURITY-BRANDS-19-100E-Advantage-DKLP-Economy-Keypad-Post-Mount-
fig13

Things to Know

*The Star Key ()**
The star key deletes your current entry.
If you happen to make a mistake keying in a code, simply press the star key to delete the entire entry and start over.

The Pound Key (#)
The pound key is good for one thing and one thing only: exiting Programming Mode. Whenever you’re in Programming Mode, simply press the pound key to get out.

Master Reset Procedure
If for some reason the Master Code and/or Latch Code is forgotten, a reset procedure is available to remedy the situation.
This procedure can be found on Page 4 of this guide.

NOTE: Green arrow indicates “good” tone on keypad. Always wait for good tone before moving on.

Programming Sub Modes

  1.  Add Access Code(s)
  2. Delete All Codes
  3.  Delete Code(s)
  4. Change Master Code
  5. Set Latch Code
  6. Set Relay Output Time

Master Reset Procedure

This procedure is used if the Master Code is unknown, or if the Latch Code is unknown and the unit is in Latch Mode. All other codes will be retained after completing this procedure.
NOTE: If an error is made during these procedures, an “error” tone will sound, and you must start again from the beginning.

  • Step 1 – Open front panel on unit.

  • Step 2 – Disconnect power.
    Remove one power wire from screw terminal on circuit board by unscrewing and removing.

  • Step 3 – Press and hold Reset Button; reconnect power; then release Reset Button. Insert removed power wire back into screw terminal and screw down to secure. Unit will sound one (1) tone. Release Reset Button after you hear tone.

  • Step 4 – Close front panel on unit.
    The Master Code is now reset to default (1251).

NEED HELP

Call 972-474-6390
Email [email protected]
We are available Mon–Fri / 8am–5pm Central

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

SECURITY BRANDS User Manuals

Related Manuals