SECURITY BRANDS 27-240 Edge Door Controller User Guide

June 4, 2024
SECURITY BRANDS

27-240 Edge Door Controller
User Guide

WARNING
AUTOMATIC GATES CAN CAUSE SERIOUS INJURY OR DEATH!
ALWAYS CHECK THAT THE GATE PATH IS CLEAR BEFORE OPERATING!
REVERSING OR OTHER SAFETY DEVICES SHOULD ALWAYS BE USED!
CAUTION
Fully tighten cable glands and secure cover with all mounting screws after installing, servicing, and/or programming.
For optimal Bluetooth connection, avoid mounting the unit inside a metal enclosure.
Failure to follow these instructions can damage the unit and/or cause it not to function correctly!

What’s what?

All important components are labeled Unit shown with the front panel open.
Wiring/cabling not shown for clarity.

Connect wires.

Feed wires through cable gland(s) on the unit, and connect as shown using included screwdriver. Excessive force can damage the unit!
Additional wiring diagrams can be found on Pages 5 and 6.
CAUTION
If the included 12-V AC/DC adapter will not be used, please go to Page 4 and follow the procedure, Using a Third-Party Power Source. Do not exceed 24 VAC/DC! Failure to choose a compatible power source can damage the unit!
Using a Third-Party Power Source (Optional)
IMPORTANT
If you would like to use a third-party power source such as solar, verify that it conforms to the following specs:

Input| 12–24 VAC/DC
no more than 10% beyond this range
---|---
Current Draw| less than 111 mA @ 12 VDC
less than 60 mA @ 24 VDC

CAUTION
Double-check that you have wired from positive on the Edge unit to positive on your power source and negative on the Edge unit to negative on your power source.
Reverse polarity can damage the unit!
STOP
Before going forward, double-check all wiring and make sure the unit has power!
Wiring diagrams for connecting to accessory devices can be found on Pages 5 and 6.
For connecting accessories not mentioned, please contact Technical Support.
Make sure the gate or door path is clear before completing Step 7!
SECURITY BRANDS 27 240 Edge Door Controller - fig 5SECURITY BRANDS 27 240 Edge Door Controller - fig
6

Event Inputs

Wiring for accessories such as a request-to-exit device

Digital Inputs

Wiring to various accessories
SECURITY BRANDS 27 240 Edge Door Controller - fig 8

Wiegand Device

Wiring for a Wiegand device
Wiegand configuration instructions can be found on Page 12.
SECURITY BRANDS 27 240 Edge Door Controller - fig 9 CAUTION
Disconnect power to the Edge unit before connecting Wiegand devices. Failure to disconnect power can damage the unit!
Downloading the Edge Smart Keypad App for iOS/Android
The Edge Smart Keypad app is for ADMINISTRATOR USE ONLY and is not intended for users.

a Grab your smartphone or tablet.
(These steps are optional. The unit can be fully programmed from the keypad.)
b Navigate to your app store, and search for “edge smart keypad.”
c Find the Edge Smart Keypad app by Security Brands, Inc. and download it.
Edge Smart Keypad
Security Brands, Inc.
NEED HELP
You can find plenty of useful resources online to help you get your new Edge unit up and running quickly and easily.
Go to securitybrandsinc.com/edge/ If you need further assistance, please call Technical Support at 972-474-6390.

Pairing Edge Unit

Connect your mobile device to your Edge unit for use with the app.
The app is available for administrators who want to use it. Nearly all programming functionality is available via the Programming Pad.
IMPORTANT! Make sure your Edge unit is powered on and that Bluetooth is enabled on your mobile device or pairing will not work.
Step 1 – Grab your mobile device and open the Edge Smart Keypad app.
If you do not have the app, follow the steps on this page for downloading it.
Step 2 – Fill out your account information and tap the “Sign Up” button.
If you have already created an account, you will log in instead.
Step 3 – On the Paired Keypads screen, tap the “Add Keypad” button.
Step 4 – On the Add Keypad screen, tap the Edge unit you want to pair.
If you do not see any Edge units listed, make sure your Edge unit is powered on and is in Bluetooth range.
Step 5 – Complete the procedure shown on your mobile device.
These steps will be completed using the PIN pad on your Edge unit.
Step 6 – Enter the Master Code (default is 1251) on your mobile device.
Step 7 – Enter the code shown on your mobile device at the Edge unit.
This step must be completed within the time duration displayed.
Step 8 – Change your Master Code if you like.
This step is recommended, but optional, and can be done at a later time.
Your new Edge unit is now paired and will appear on the Paired Keypads screen. Tapping on the Edge unit on this screen will give you access to relay control and full access control management of the Edge unit from within the app.
**** For more information and guidance, please go to securitybrandsinc.com/edge/ or call Technical Support at 972-474-6390 for assistance.

Direct Programming / Unit Configuration

SECURITY BRANDS 27 240 Edge Door Controller - fig 10The green arrow indicates a “good” tone on the unit. Always wait for a good tone before moving on. By default, these codes are unavailable for use: 1251, 1273, 1366, 1381, 1387, 1678, 1752, 1985.
FIND MORE
For all programming not shown here, as well as reset procedures and the Edge Smart Keypad app user guide, please visit our Edge start page:
securitybrandsinc.com/edge/
Programming Sub Modes

Programming Sub Modes

1          Add Access Code(s) to Relay A
2          Delete Code (Non-Wiegand)
3          Change Master Code
4 – 3    Add Latch Code to Relay B
4 – 4    Change Sleep Code
4 – 5    Change Code Length (Non-Wiegand)
4 – 6    Change Relay Trigger Time| 4 – 7    Enable/Disable Timers and Schedules
4 – 8    Enable/Disable “3 Strikes, You’re Out”
4 – 9    Configure Event Input 1
5          Add Latch Code to Relay A
6          Configure Wiegand Inputs
7          Add Access Code(s) to Relay B
8          Add Limited-Use Code
0          Delete All Codes and Timers

Things to Know
*The Star Key ()
If a mistake is made, pressing the star key deletes your entry. Two beeps will sound.
The Pound Key (#)
The pound key is good for one thing and one thing only: exiting the programming mode.
Change Relay Trigger Time
Enable/Disable “3 Strikes, You’re Out”
(When enabled, the unit will sound an alarm and go into a 90-second lockdown for 90 seconds when an incorrect code is entered three times.
SECURITY BRANDS 27 240 Edge Door Controller - fig 12
Configure Wiegand Input
(Allows enabling or disabling of a Wiegand input and configuration of the Wiegand device type. For the tag reader type, use the Edge Smart Keypad app.)
Change Default Facility Code
Toggle Silent Mode
(Toggles Silent Mode, which mutes all audible-tone feedback on the unit)
SECURITY BRANDS 27 240 Edge Door Controller - fig 15
Configure Event Input 1
(Allows an external device to affect keypad operation or trigger a relay. To configure additional inputs, use the Edge Smart Keypad app.)
Mode 1 – Remote Open Mode
Triggers either Relay A or Relay B when the event input state changes from normally open (N/O) to normally closed (N/C).
Mode 2 – Log Mode
Makes log entry of event input state when event input state changes from normally open (N/O) to normally closed (N/C).
Mode 3 – Remote Open and Log Mode
Combine Modes 1 and 2.
Mode 4 – Arming Circuit Mode
Enables either Relay A or Relay B when the event input state changes from normally open (N/O) to normally closed (N/C). Otherwise, the selected relay is disabled.
Mode 5 – Remote Operation Mode
Triggers or latches either Relay A or Relay B when event input state changes from normally closed (N/C) to normally open (N/O).
Mode 0 – Event Input 1 Disabled
Modes 1, 3, and 4
Configure Event Input 1 (continued)
(Allows an external device to affect keypad operation or trigger a relay. To configure additional inputs, use the Edge Smart Keypad app.)
SECURITY BRANDS 27 240 Edge Door Controller - fig 17SECURITY BRANDS 27 240 Edge Door Controller - fig
18
Disable Event/Digital Inputs (Mode 0)
**

Direct Programming / External Wiegand Keypad

Add Wiegand Keypad Access Code(s)
(Uses default facility code; to add multiple codes, enter each of them before pressing the pound key)
On Both Wiegand Inputs
SECURITY BRANDS 27 240 Edge Door Controller - fig 20 On Wiegand Input 1 or 2
SECURITY BRANDS 27 240 Edge Door Controller - fig 21Add Wiegand Keypad Manager Access Code(s)

(Uses default facility code; to add multiple codes, enter each of them before pressing the pound key)
On Both Wiegand Inputs
On Wiegand Input 1 or 2
Add Wiegand Keypad Latch Code(s)
(Uses default facility code; to add multiple codes, enter each of them before pressing the pound key)
On Both Wiegand Inputs
On Wiegand Input 1 or 2
Delete Wiegand Keypad Code(s)
(Uses default facility code; to delete multiple codes, enter each of them before pressing the pound key)
On Both Wiegand Inputs
SECURITY BRANDS 27 240 Edge Door Controller - fig 26 On Wiegand Input 1 or 2

**Direct Programming / External Wiegand Card Reader

**

Add Wiegand Card/Remote/Vehicle Tag Access Code(s)
(To add multiple codes, enter each of them before pressing the pound key)
SECURITY BRANDS 27 240 Edge Door Controller - fig 28 Bulk Add Wiegand Card/Remote/Vehicle Tag Access Code(s)
SECURITY BRANDS 27 240 Edge Door Controller - fig 29 Add Wiegand Card/Remote/Vehicle Tag Latch Code(s)

(To add multiple codes, enter each of them before pressing the pound key)
SECURITY BRANDS 27 240 Edge Door Controller - fig 30 Bulk Add Wiegand Card/Remote/Vehicle Tag Latch Code(s)
SECURITY BRANDS 27 240 Edge Door Controller - fig 31 Add Wiegand Card/Remote/Vehicle Tag Manager Access Code(s)

(To add multiple codes, enter each of them before pressing the pound key)
SECURITY BRANDS 27 240 Edge Door Controller - fig 32 Bulk Add Wiegand Card/Remote/Vehicle Tag Manager Access Code(s)
Delete Wiegand Card/Remote/Vehicle Tag Manager Code(s)

(To add multiple codes, enter each of them before pressing the pound key)
Bulk Delete Wiegand Card/Remote/Vehicle Tag Code(s)
SECURITY BRANDS 27 240 Edge Door Controller - fig 35

Notes —
© 2021 Security Brands, Inc. All rights reserved.
SECURITY BRANDS 27 240 Edge Door Controller - icon 1
NEED HELP
Call 972-474-6390
Email [email protected]
We are available Mon–Fri / 8 am–5 pm Central

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

SECURITY BRANDS User Manuals

Related Manuals