SECURITY BRANDS 16-M7 Ascent Unit User Guide

June 6, 2024
SECURITY BRANDS

SECURITY BRANDS 16-M7 Ascent Unit

OVERVIEW

  1. Unpack box and make sure you have all items shown here. (Screwdriver not shown.)SECURITY-BRANDS-16-M7-Ascent-Unit-fig-1

  2. Unlock and open front door of unit for mounting, wiring, and setup.
    STOP: This is a cellular accessory for a gate or door. An uninterrupted cellular connection CANNOT BE GUARANTEED!
    An emergency egress or primary entry mechanism SHOULD ALWAYS BE USED! (transmitter, fire box, mechanical release)
    Consult with your dealer, distributor, and/or system designer for more information.
    WARNING: AUTOMATIC GATES CAN CAUSE SERIOUS INJURY OR DEATH!
    ALWAYS CHECK THAT THE GATE PATH IS CLEAR BEFORE OPERATING!
    REVERSING OR OTHER SAFETY DEVICES SHOULD ALWAYS BE USED!
    IMPORTANT: This Ascent unit WILL NOT WORK until the activation process is COMPLETE!
    Follow the included Activation Guide to get this unit activated.
    If you need help or have any questions, please contact Summit Control at 972-474-6422.

  3. Mount unit to pedestal using included mounting hardware. (This step may be completed later.)

IMPORTANT: We recommend mounting the unit on a gooseneck pedestal using the included mounting hardware.
If using an alternate mounting, the 4G LTE Antenna Extension Kit (Model 16-ANTX-1) should be purchased and installed.
Failure to do so may result in NO SIGNAL!

CAUTION: Use all four carriage bolts when mounting the unit to a pedestal.
Leave the “hockey puck” antenna in place even if using an antenna extension.
Seal all openings created in the enclosure.
Failure to follow these instructions can damage the unit!

All important components labeled

SECURITY-BRANDS-16-M7-Ascent-Unit-fig-5

Connect wires

Feed wires through the back of the unit, and connect as shown using included screwdriver.
Excessive force can damage the unit!

CAUTION: If the included 12-V AC/DC adapter will not be used, please go to Page 5 and follow the procedure, Using a Third-Party Power Source.
Do not exceed 24 VAC/DC! Failure to choose a compatible power source can damage the unit!

Ascent Power and Relay Terminals: Gate Operator / Door Opener

SECURITY-BRANDS-16-M7-Ascent-Unit-fig-4

Status Check

Wiring to enable Gate Status CheckSECURITY-BRANDS-16-M7-Ascent-Unit-
fig-6

Event Input

Wiring for accessories such as a request-to-exit device

Wiegand Device

Wiring for a Wiegand device such as a card reader

SECURITY-BRANDS-16-M7-Ascent-Unit-fig-8