naturewater 64430 5 Stage Compact Reverse Osmosis Instruction Manual
- September 7, 2024
- Naturewater
Table of Contents
- 64430 5 Stage Compact Reverse Osmosis
- Product Information
- Specifications
- Product Usage Instructions
- Safety Instructions
- System Function
- Tools and Parts Required
- Placement of Units
- Attaching and Removing Water Lines
- Q: Where can I find the most recent version of the manual?
- Q: What safety precautions should I take when using the
64430 5 Stage Compact Reverse Osmosis
Product Information
Specifications
-
Model: 5-stage Reverse Osmosis System
-
Filter Stages: PP sediment filter, Granular activated carbon
filter, Activated carbon block filter, Reverse osmosis membrane,
Post activated carbon filter -
Components: High-pressure pump, Pressure tank, Automatic
shut-off valve, Flow restrictor, Flush solenoid valve, Check valve,
High-pressure switch, Ball valve, Inline carbon filter
Product Usage Instructions
Safety Instructions
Read and follow the operating instructions and safety
information before using for the first time. Keep these operation
instructions safe.
System Function
The system includes components such as feed water, PP filter,
Granular activated carbon filter, Activated carbon block filter,
Reverse osmosis membrane, Waste water drain, Pure water outlet, and
Pressure tank.
Tools and Parts Required
Prepare the following tools and parts before installation:
Knife, Electric drill, Sealing tape, Hammer, Open-end spanner,
Scissors, Water tap, Assembly spanner, Water pipe, Clamp, Bracket
for tap, Reverse osmosis membrane, Operating instructions, Feed
water valve, T-piece, Waste water clamp.
Placement of Units
The units can be placed either under the sink or on the
countertop. Ensure that all components and hoses are not exposed to
frost or direct sunlight.
Attaching and Removing Water Lines
To attach the water line, insert it into the designated slot and
secure it with a clip. To remove the water line, release the lock
by pressing and then pull out the water line.
FAQ
Q: Where can I find the most recent version of the manual?
A: The latest version of the manual in various languages can be
found on the manufacturer’s website via the provided link.
Q: What safety precautions should I take when using the
device?
A: It is recommended to read and understand the operation
instructions carefully to minimize the risk of injury.
Operation Manual 5-stage Reverse Osmosis System
6442964432
Illustration similar, may vary depending on model
Read and follow the operating instructions and safety information before using
for the first time. Technical changes reserved! Due to further developments,
illustrations, functioning steps, and technical data can differ
insignificantly. Updating the documentation If you have suggestions for
improvement or have found any irregularities, please contact us.
The information contained in this document may alter at any time without
previous notice. It is prohibited to copy or spread any parts of this document
in any way without prior written allowance. All rights reserved. The WilTec
Wildanger Technik GmbH cannot be held accountable for any possible mistakes in
this operating manual, nor in the diagrams and figures shown. Even though, the
WilTec Wildanger Technik GmbH has undergone biggest possible efforts to ensure
that the operating manual is complete, faultless, and up to date, mistakes
cannot be entirely avoided. If you should find a mistake or wish to make a
suggestion for improvement, we look forward to hearing from you.
Send an e-mail to:
service@wiltec.info
or use our contact form:
https://www.wiltec.de/contacts/
The most recent version of this manual in various languages can be found in
our online shop via:
https://www.wiltec.de/docsearch
Our postal address is:
WilTec Wildanger Technik GmbH Königsbenden 12 52249 Eschweiler Germany
To return orders for exchange, repair, or other purposes, please use the
following address. Attention! To allow for a smooth execution of your
complaint or return, it is important to contact our customer service team
before returning the goods.
Returns Department WilTec Wildanger Technik GmbH Königsbenden 28 52249
Eschweiler
E-mail: service@wiltec.info Tel: +49 2403 555920 Fax: +49 2403 5559215
Item 6442964432
Page 2 07 2024-1
Introduction
Thank you for purchasing this quality product. To minimise the risk of injury
we urge that our clients take some basic safety precautions when using this
device. Please read the operation instructions carefully and make sure you
have understood its content. Keep these operation instructions safe.
Safety instructions
· This device is intended for operation and use according to the instructions
in this manual. It is not designed for operation outside the specified
parameters, and any attempt to do so or to tamper with the device can result
in damage to the device and/or personal injury.
· This device is not a toy and should be kept out of the reach of young
children. · If the device requires maintenance or repair, please contact a
service technician. · Ensure that the temperature of the feed water is above 4
. If the water temperature is below
4 , ice can form and damage the device. · This system contains filters that
need to be replaced at certain intervals. Replacement intervals
vary depending on usage. · Please install the system with potable water only.
If using non-potable water sources, the system
will not function properly, and additional pre-treatment may be required. ·
Ensure that the water pressure is approximately 4 bar. If the source water
pressure exceeds
the maximum pressure, a pressure reducing valve may be required. · Ensure that
the temperature of the source water is between 5 and 45 . The system will not
function properly if these temperatures are exceeded. Do not install at a hot
water source. · Do not use the system for visibly contaminated water such as
raw sewage or well water. · Do not disassemble, open, or modify the device.
Tampering with the device can lead to mal-
functions or damage and will void the warranty. · Do not cover the device, as
this will impede heat dissipation and can cause damage or fires. · Do not
place objects on the device, as this can cause damage to the device and leaks.
· Adhere to all recommended values for operating pressure and temperatures,
otherwise, the
device may be damaged. · Avoid contact with corrosive materials. · Protect
from heat.
Filters and filter stages
Filter Stage 1
Filter Stage 2
Filter Stage 3
PP sediment filter Granular activated Activated carbon carbon filter (GAC) block filter (CTO)
Filter Stage 4
Filter Stage 5
Reverse osmosis Post activated car-
membrane (RO)
bon filter
Item 6442964432
Page 3 07 2024-1
System function
Name 1 Feed water 2 PP filter 3 Granular activated carbon filter 4 Activated carbon block filter 5 High-pressure pump
Name 6 Reverse osmosis membrane 7 Waste water 8 Drain 9 Pure water 10 Pressure tank
Technical data
Voltage and frequency Power output (W) Reverse osmosis element capacity (GPD)
Inlet TDS (ppm) Chlorine content (ppm) Average RO rejection rate (%) Inlet
water pressure (minmax) (bar) Inlet water temperature (minmax) () Type of
flushing
110240 V 50/60 Hz 2536 50 / 75 / 80 / 100 / 125 2500 0,2 98 410 545 Automatic
Item 6442964432
Page 4 07 2024-1
Automatic shut-off valve water flow
Name
1
T-piece
11
2
Feed water valve
12
3
Low-pressure switch
13
4
PP filter
14
5
Granular activated carbon filter
15
6
Activated carbon block filter
16
7
Booster pump
17
8
Inlet solenoid valve
18
9
Membrane housing
19
10
Reverse osmosis membrane
Name Flow restrictor Flush solenoid valve Check valve High-pressure switch
Ball valve Pressure tank Inline carbon filter
Faucet Flowing water
Item 6442964432
Page 5 07 2024-1
Tools and parts required
Name 1 Knife 2 Electric drill 3 Sealing tape 4 Hammer 5 Open-end spanner 6 Scissors 7 Water tap 8 Assembly spanner
Name 9 Water pipe 10 Clamp 11 Bracket for tap 12 Reverse osmosis membrane 13 Operating instructions 14 Feed water valve 15 T-piece 16 Waste water clamp
Placement of units
· This device is designed to be installed under the sink or countertop.
However, if you need to place this device in a suitable location due to lack
of space or other constraints,
· When choosing the installation location, ensure that the cold-water line,
drain pipe, and power outlet are easily accessible and that there is enough
space for filter replacement.
Item 6442964432
Page 6 07 2024-1
Under the sink
On the countertop
Note! All components and hoses should be placed in an area that is not exposed to frost or direct sunlight.
Quick coupling Attaching the water line
Removing the water line
Name/Description
1 Insert water line
2 Insert clip
3 Remove clip
Name/Description
4 Release lock by pressing
5 Pull out water line
Item 6442964432
Page 7 07 2024-1
Feed water valve and T-piece · Install the T-piece and feed water valve
according to the diagram. · Wrap the threads of the feed water valve and
T-piece with sealing tape. · Connect the white feed water hose from the device
to the feed water valve.
· Install the feed water valve. · Install the T-piece of the feed water valve
and then connect the mains water. · Attention! The water supply to your device
must come from the cold-water line. Note! Use only cold water, as hot water
can damage your device. Softened feed water extends the life of the reverse
osmosis membrane.
Installation of the wastewater clamp · Place the wastewater clamp on the
drainpipe above the siphon and tighten it. · Using the wastewater clamp as a
guide, drill a 6 mm hole that is sufficient to pass the ¼ hose through one
side of the drainpipe. Do not drill through both sides. · Connect the red
wastewater hose from the device to the wastewater clamp.
Attention! · Cut the pipes cleanly and at right angles. Otherwise, poor
connections and potential leaks may occur. · The lowest point of the pipe
should be the connection point at the wastewater clamp. The pipe should not
sag, as this can cause excessive noise when the wastewater flows to the drain.
Item 6442964432
Page 8 07 2024-1
Wastewater clamp assembly
Name/description 1 Drainpipe 2 Screw M6×35 3 Wastewater clamp front wall 4 Insert
Name/description 5 Union nut 6 Drainpipe 7 M6 nut 8 Wastewater clamp back wall
Faucet installation
· Select a suitable location near your sink for the faucet. · Drill a hole
with a diameter of 12 mm in the countertop. · Install washers, plates,
gaskets, and nuts in the order
shown in the diagram and tighten them on the countertop. · Attach the blue
pure water hose to the bottom of the faucet and connect the hose to the
device. · Install the faucet at the desired location according to the diagram,
either on the left or right side, depending on the faucet.
Item 6442964432
Page 9 07 2024-1
Operation and maintenance LED display and control panel
· When turning on, the light will flash brightly, the buzzer will sound once,
the screen will blink once, and the system will start working. During the
automatic flushing, which lasts 60 s, the flushing symbol (Flush) will blink.
· The device is in water production mode when the water production symbol
(Source) is displayed. Once the pressure tank is full, the water production
symbol will turn off and the full pressure tank symbol (Full) will light up.
· In case of water shortage or insufficient water pressure, the water shortage
symbol (Lack) will light up and the buzzer will sound 10 times.
· The machine produces water for 2 hours without flushing during operation. It
will automatically flush for 30 s.
· If the machine operates for 6 hours or a leakage probe is detected, the
machine will automatically stop water production, the repair symbol (Check)
will blink, and the buzzer will sound.
Filter replacement reminder
· Filter stage 1: · Filter stage 2 and 3: · Filter stage 4: · Filter stage 5:
after 270 hours after 540 hours after 1620 hours after 810 hours
Reminder for each filter: When there is increased water consumption and decreased filter performance, the set alarm will sound, and the display will blink. After replacing the filter, press the reset button to reset the filter recognition.
Filter reset
1. Briefly press the reset button for less than 3 s. The buzzer will sound
once. 2. Briefly press the reset button again until the required filter for
reset is selected. 3. Press the reset button for more than 3 s. After three
seconds, a signal tone will sound, indicating
a successful filter reset. 4. After the signal tone, press the reset button
again. After 5 s without interaction, the filter reset
will automatically exit.
Flushing
· Press the flush button until the buzzer sounds once. The flushing mode will
begin. · Press the flush button in flushing mode to end the program. · Press
the flush button when water is being produced or the water level is full and
flush the
reverse osmosis membrane for 120 s.
Item 6442964432
Page 10 07 2024-1
Flushing the prefilters (first installation, before installing the reverse
osmosis element)
Prepare the system for operation by flushing the prefilters:
1. Disconnect the inlet hose of the reverse osmosis element from the element
housing cap. Open the water line and inlet valve and let the system run
through the 3 prefilters.
2. Direct the output water into a container or drain. 3. Continue flushing
until the output water is visibly clean. Reconnect the hose. 4. Note: The pump
and membrane can be severely damaged if the system is not flushed through
the prefilters. Discard all water from the flushing process as it is not
suitable for use or consumption. 5. After flushing the prefilters, connect and
open all valves. 6. Wait about 2 min before opening the faucet. 7. Allow the
system to flush for the first 1015 min with the faucet open. Do not use any
water from the reverse osmosis device at this time.
Flushing the pressure tank
1. After flushing the prefilters, operate the device and let the pressure
tank fill. 2. It takes approximately 45 min for the tank to fill. Once the
tank is full, drain the pressure tank by
leaving the faucet open. 3. Once the tank is completely empty, close the
faucet and let the tank fill again. 4. After flushing the pressure tank, the
device is ready for use.
Regular operation
Once the system is set up and connected to a power source, it will
automatically start water treatment when the faucet is opened. When the faucet
is closed, the device will automatically shut off. After use, the device will
automatically flush if it is equipped with an automatic flushing function.
Filter maintenance
To ensure optimal operation of the device, regular maintenance is required.
The frequency of maintenance depends on the quality of the raw water and the
intensity of system use. Here are some guidelines for scheduled filter
replacements, though the frequency of filter changes may vary. If unsure,
please contact a service technician.
1. Replace the PP filter every 36 months or as needed. 2. Replace the carbon
block filter every 612 months or as needed. 3. Replace the reverse osmosis
membrane every 1824 months or as needed. 4. Replace the inline carbon filter
every 612 months or as needed.
If you are away for an extended period or will not be using the device for a
long time, disconnect the device from the power source. When the device has
been shut down and not used for an extended period, perform the same flushing
procedure as during initial start-up.
Item 6442964432
Page 11 07 2024-1
Filter and membrane replacement
1. Close the inlet valve for the raw water. 2. Close the ball valve of the
pressure tank. 3. Open the faucet and drain the remaining water from the
system. 4. Open the cover of the N03 unit and then the cover of the filter
housing. 5. Insert the filters and membrane into their respective housings.
Attention! The replacement schedule for filters and membranes is for reference only. The actual replacement schedule may vary depending on usage and the quality of the raw water. Consult your local dealer for further details on the replacement schedule.
Item 6442964432
Page 12 07 2024-1
Troubleshooting
Problem
Possible cause
Suggested solution
No water production
Water supply turned off
Turn on feed water.
Not enough water production Water supply blocked
Remove blocking.
Feed water valve clogged
Open or unclog valve.
No drain
Clean or replace check valve.
Pump not running
Low feed water pressure
Check source water supply.
No power supply or loose con- Turn on power supply, check
nection
connection.
Transformer burned out
Replace transformer.
Pump is running, but system is Prefilter clogged not producing water
Replace filter cartridges.
Inlet solenoid valve not function- Repair or replace valve. ing
System does not switch off
High-pressure switch not operat- Repair or replace switch. ing
Abnormal pump noise
Prefilter clogged
Replace filter cartridges.
Low feed water pressure
Adjust feed water pressure.
No discharge water
Drain flow restrictor clogged
Replace drain flow restrictor.
Produced water has a bad taste Post/line filter needs replace- Replace filter cartridges. ment
Hoses leaking
Incorrect hose connection
Check/reposition hoses.
Defective or damaged hoses Replace hose section.
Item 6442964432
Page 13 07 2024-1
Disposal regulations
EU guidelines regarding the disposal of scrap electric appliances (WEEE,
2012/19/EU) were implemented in the law related to electrical and electronic
equipment and appliances.
All WilTec electric devices that fall under the WEEE regulations are labelled
with the crossed-out wheeled waste bin logo. This logo indicates that this
electric equipment must not be disposed with the domestic waste.
The company WilTec Technik GmbH has been registered in the German registry EAR
under the WEEEregistration number DE45283704.
Disposal of used electrical and electronic appliances (intended for use in the
countries of the European Union and other European countries with a separate
collection system for these appliances). The logo on the article or on its
packaging points out that this article must not be treated as normal household
waste but must be disposed to a recycling collection point for electronic and
electrical waste equipment. By contributing to the correct disposal of this
article you protect the environment and the health of your fellow men.
Environment and health are threatened by inappropriate disposal.
Material recycling helps reduce the consumption of raw materials.
Additional information on recycling this article can be provided by your local
community, municipal waste disposal facilities, or the store where you
purchased the article.
Address: WilTec Wildanger Technik GmbH
Königsbenden 12 / 28 D-52249 Eschweiler
Important notice:
The reprint or reproduction, even of excerpts, and any commercial use, even in part, of this instruction manual require the written permission of WilTec Wildanger Technik GmbH.
Item 6442964432
Page 14
07 2024-1
References
Read User Manual Online (PDF format)