naturewater 64430 5 Stage Compact Reverse Osmosis Instruction Manual

September 7, 2024
Naturewater

64430 5 Stage Compact Reverse Osmosis

Product Information

Specifications

  • Model: 5-stage Reverse Osmosis System

  • Filter Stages: PP sediment filter, Granular activated carbon
    filter, Activated carbon block filter, Reverse osmosis membrane,
    Post activated carbon filter

  • Components: High-pressure pump, Pressure tank, Automatic
    shut-off valve, Flow restrictor, Flush solenoid valve, Check valve,
    High-pressure switch, Ball valve, Inline carbon filter

Product Usage Instructions

Safety Instructions

Read and follow the operating instructions and safety
information before using for the first time. Keep these operation
instructions safe.

System Function

The system includes components such as feed water, PP filter,
Granular activated carbon filter, Activated carbon block filter,
Reverse osmosis membrane, Waste water drain, Pure water outlet, and
Pressure tank.

Tools and Parts Required

Prepare the following tools and parts before installation:
Knife, Electric drill, Sealing tape, Hammer, Open-end spanner,
Scissors, Water tap, Assembly spanner, Water pipe, Clamp, Bracket
for tap, Reverse osmosis membrane, Operating instructions, Feed
water valve, T-piece, Waste water clamp.

Placement of Units

The units can be placed either under the sink or on the
countertop. Ensure that all components and hoses are not exposed to
frost or direct sunlight.

Attaching and Removing Water Lines

To attach the water line, insert it into the designated slot and
secure it with a clip. To remove the water line, release the lock
by pressing and then pull out the water line.

FAQ

Q: Where can I find the most recent version of the manual?

A: The latest version of the manual in various languages can be
found on the manufacturer’s website via the provided link.

Q: What safety precautions should I take when using the

device?

A: It is recommended to read and understand the operation
instructions carefully to minimize the risk of injury.

Operation Manual 5-stage Reverse Osmosis System
64429­64432
Illustration similar, may vary depending on model
Read and follow the operating instructions and safety information before using for the first time. Technical changes reserved! Due to further developments, illustrations, functioning steps, and technical data can differ insignificantly. Updating the documentation If you have suggestions for improvement or have found any irregularities, please contact us.

The information contained in this document may alter at any time without previous notice. It is prohibited to copy or spread any parts of this document in any way without prior written allowance. All rights reserved. The WilTec Wildanger Technik GmbH cannot be held accountable for any possible mistakes in this operating manual, nor in the diagrams and figures shown. Even though, the WilTec Wildanger Technik GmbH has undergone biggest possible efforts to ensure that the operating manual is complete, faultless, and up to date, mistakes cannot be entirely avoided. If you should find a mistake or wish to make a suggestion for improvement, we look forward to hearing from you.
Send an e-mail to:
service@wiltec.info
or use our contact form:
https://www.wiltec.de/contacts/
The most recent version of this manual in various languages can be found in our online shop via:
https://www.wiltec.de/docsearch
Our postal address is:
WilTec Wildanger Technik GmbH Königsbenden 12 52249 Eschweiler Germany
To return orders for exchange, repair, or other purposes, please use the following address. Attention! To allow for a smooth execution of your complaint or return, it is important to contact our customer service team before returning the goods.
Returns Department WilTec Wildanger Technik GmbH Königsbenden 28 52249 Eschweiler
E-mail: service@wiltec.info Tel: +49 2403 55592­0 Fax: +49 2403 55592­15

https://www.naturewater.eu

Item 64429­64432

Page 2 07 2024-1

Introduction
Thank you for purchasing this quality product. To minimise the risk of injury we urge that our clients take some basic safety precautions when using this device. Please read the operation instructions carefully and make sure you have understood its content. Keep these operation instructions safe.

Safety instructions
· This device is intended for operation and use according to the instructions in this manual. It is not designed for operation outside the specified parameters, and any attempt to do so or to tamper with the device can result in damage to the device and/or personal injury.
· This device is not a toy and should be kept out of the reach of young children. · If the device requires maintenance or repair, please contact a service technician. · Ensure that the temperature of the feed water is above 4 . If the water temperature is below
4 , ice can form and damage the device. · This system contains filters that need to be replaced at certain intervals. Replacement intervals
vary depending on usage. · Please install the system with potable water only. If using non-potable water sources, the system
will not function properly, and additional pre-treatment may be required. · Ensure that the water pressure is approximately 4 bar. If the source water pressure exceeds
the maximum pressure, a pressure reducing valve may be required. · Ensure that the temperature of the source water is between 5 and 45 . The system will not
function properly if these temperatures are exceeded. Do not install at a hot water source. · Do not use the system for visibly contaminated water such as raw sewage or well water. · Do not disassemble, open, or modify the device. Tampering with the device can lead to mal-
functions or damage and will void the warranty. · Do not cover the device, as this will impede heat dissipation and can cause damage or fires. · Do not place objects on the device, as this can cause damage to the device and leaks. · Adhere to all recommended values for operating pressure and temperatures, otherwise, the
device may be damaged. · Avoid contact with corrosive materials. · Protect from heat.

Filters and filter stages

Filter Stage 1

Filter Stage 2

Filter Stage 3

PP sediment filter Granular activated Activated carbon carbon filter (GAC) block filter (CTO)

Filter Stage 4

Filter Stage 5

Reverse osmosis Post activated car-

membrane (RO)

bon filter

https://www.naturewater.eu

Item 64429­64432

Page 3 07 2024-1

System function

Name 1 Feed water 2 PP filter 3 Granular activated carbon filter 4 Activated carbon block filter 5 High-pressure pump

Name 6 Reverse osmosis membrane 7 Waste water 8 Drain 9 Pure water 10 Pressure tank

Technical data
Voltage and frequency Power output (W) Reverse osmosis element capacity (GPD) Inlet TDS (ppm) Chlorine content (ppm) Average RO rejection rate (%) Inlet water pressure (min­max) (bar) Inlet water temperature (min­max) () Type of flushing

110­240 V 50/60 Hz 25­36 50 / 75 / 80 / 100 / 125 2500 0,2 98 4­10 5­45 Automatic

https://www.naturewater.eu

Item 64429­64432

Page 4 07 2024-1

Automatic shut-off valve water flow

Name

1

T-piece

11

2

Feed water valve

12

3

Low-pressure switch

13

4

PP filter

14

5

Granular activated carbon filter

15

6

Activated carbon block filter

16

7

Booster pump

17

8

Inlet solenoid valve

18

9

Membrane housing

19

10

Reverse osmosis membrane

Name Flow restrictor Flush solenoid valve Check valve High-pressure switch
Ball valve Pressure tank Inline carbon filter
Faucet Flowing water

https://www.naturewater.eu

Item 64429­64432

Page 5 07 2024-1

Tools and parts required

Name 1 Knife 2 Electric drill 3 Sealing tape 4 Hammer 5 Open-end spanner 6 Scissors 7 Water tap 8 Assembly spanner

Name 9 Water pipe 10 Clamp 11 Bracket for tap 12 Reverse osmosis membrane 13 Operating instructions 14 Feed water valve 15 T-piece 16 Waste water clamp

Placement of units
· This device is designed to be installed under the sink or countertop. However, if you need to place this device in a suitable location due to lack of space or other constraints,
· When choosing the installation location, ensure that the cold-water line, drain pipe, and power outlet are easily accessible and that there is enough space for filter replacement.

https://www.naturewater.eu

Item 64429­64432

Page 6 07 2024-1

Under the sink

On the countertop

Note! All components and hoses should be placed in an area that is not exposed to frost or direct sunlight.

Quick coupling Attaching the water line

Removing the water line

Name/Description

1 Insert water line

2 Insert clip

3 Remove clip

Name/Description

4 Release lock by pressing

5 Pull out water line

https://www.naturewater.eu

Item 64429­64432

Page 7 07 2024-1

Feed water valve and T-piece · Install the T-piece and feed water valve according to the diagram. · Wrap the threads of the feed water valve and T-piece with sealing tape. · Connect the white feed water hose from the device to the feed water valve.
· Install the feed water valve. · Install the T-piece of the feed water valve and then connect the mains water. · Attention! The water supply to your device must come from the cold-water line. Note! Use only cold water, as hot water can damage your device. Softened feed water extends the life of the reverse osmosis membrane.
Installation of the wastewater clamp · Place the wastewater clamp on the drainpipe above the siphon and tighten it. · Using the wastewater clamp as a guide, drill a 6 mm hole that is sufficient to pass the ¼ hose through one side of the drainpipe. Do not drill through both sides. · Connect the red wastewater hose from the device to the wastewater clamp.
Attention! · Cut the pipes cleanly and at right angles. Otherwise, poor connections and potential leaks may occur. · The lowest point of the pipe should be the connection point at the wastewater clamp. The pipe should not sag, as this can cause excessive noise when the wastewater flows to the drain.

https://www.naturewater.eu

Item 64429­64432

Page 8 07 2024-1

Wastewater clamp assembly

Name/description 1 Drainpipe 2 Screw M6×35 3 Wastewater clamp front wall 4 Insert

Name/description 5 Union nut 6 Drainpipe 7 M6 nut 8 Wastewater clamp back wall

Faucet installation
· Select a suitable location near your sink for the faucet. · Drill a hole with a diameter of 12 mm in the countertop. · Install washers, plates, gaskets, and nuts in the order
shown in the diagram and tighten them on the countertop. · Attach the blue pure water hose to the bottom of the faucet and connect the hose to the device. · Install the faucet at the desired location according to the diagram, either on the left or right side, depending on the faucet.

https://www.naturewater.eu

Item 64429­64432

Page 9 07 2024-1

Operation and maintenance LED display and control panel

· When turning on, the light will flash brightly, the buzzer will sound once, the screen will blink once, and the system will start working. During the automatic flushing, which lasts 60 s, the flushing symbol (Flush) will blink.
· The device is in water production mode when the water production symbol (Source) is displayed. Once the pressure tank is full, the water production symbol will turn off and the full pressure tank symbol (Full) will light up.
· In case of water shortage or insufficient water pressure, the water shortage symbol (Lack) will light up and the buzzer will sound 10 times.
· The machine produces water for 2 hours without flushing during operation. It will automatically flush for 30 s.
· If the machine operates for 6 hours or a leakage probe is detected, the machine will automatically stop water production, the repair symbol (Check) will blink, and the buzzer will sound.

Filter replacement reminder

· Filter stage 1: · Filter stage 2 and 3: · Filter stage 4: · Filter stage 5:

after 270 hours after 540 hours after 1620 hours after 810 hours

Reminder for each filter: When there is increased water consumption and decreased filter performance, the set alarm will sound, and the display will blink. After replacing the filter, press the reset button to reset the filter recognition.

Filter reset

1. Briefly press the reset button for less than 3 s. The buzzer will sound once. 2. Briefly press the reset button again until the required filter for reset is selected. 3. Press the reset button for more than 3 s. After three seconds, a signal tone will sound, indicating
a successful filter reset. 4. After the signal tone, press the reset button again. After 5 s without interaction, the filter reset
will automatically exit.

Flushing

· Press the flush button until the buzzer sounds once. The flushing mode will begin. · Press the flush button in flushing mode to end the program. · Press the flush button when water is being produced or the water level is full and flush the
reverse osmosis membrane for 120 s.

https://www.naturewater.eu

Item 64429­64432

Page 10 07 2024-1

Flushing the prefilters (first installation, before installing the reverse osmosis element)
Prepare the system for operation by flushing the prefilters:
1. Disconnect the inlet hose of the reverse osmosis element from the element housing cap. Open the water line and inlet valve and let the system run through the 3 prefilters.
2. Direct the output water into a container or drain. 3. Continue flushing until the output water is visibly clean. Reconnect the hose. 4. Note: The pump and membrane can be severely damaged if the system is not flushed through
the prefilters. Discard all water from the flushing process as it is not suitable for use or consumption. 5. After flushing the prefilters, connect and open all valves. 6. Wait about 2 min before opening the faucet. 7. Allow the system to flush for the first 10­15 min with the faucet open. Do not use any water from the reverse osmosis device at this time.
Flushing the pressure tank
1. After flushing the prefilters, operate the device and let the pressure tank fill. 2. It takes approximately 45 min for the tank to fill. Once the tank is full, drain the pressure tank by
leaving the faucet open. 3. Once the tank is completely empty, close the faucet and let the tank fill again. 4. After flushing the pressure tank, the device is ready for use.
Regular operation
Once the system is set up and connected to a power source, it will automatically start water treatment when the faucet is opened. When the faucet is closed, the device will automatically shut off. After use, the device will automatically flush if it is equipped with an automatic flushing function.
Filter maintenance
To ensure optimal operation of the device, regular maintenance is required. The frequency of maintenance depends on the quality of the raw water and the intensity of system use. Here are some guidelines for scheduled filter replacements, though the frequency of filter changes may vary. If unsure, please contact a service technician.
1. Replace the PP filter every 3­6 months or as needed. 2. Replace the carbon block filter every 6­12 months or as needed. 3. Replace the reverse osmosis membrane every 18­24 months or as needed. 4. Replace the inline carbon filter every 6­12 months or as needed.
If you are away for an extended period or will not be using the device for a long time, disconnect the device from the power source. When the device has been shut down and not used for an extended period, perform the same flushing procedure as during initial start-up.

https://www.naturewater.eu

Item 64429­64432

Page 11 07 2024-1

Filter and membrane replacement
1. Close the inlet valve for the raw water. 2. Close the ball valve of the pressure tank. 3. Open the faucet and drain the remaining water from the system. 4. Open the cover of the N03 unit and then the cover of the filter housing. 5. Insert the filters and membrane into their respective housings.

Attention! The replacement schedule for filters and membranes is for reference only. The actual replacement schedule may vary depending on usage and the quality of the raw water. Consult your local dealer for further details on the replacement schedule.

https://www.naturewater.eu

Item 64429­64432

Page 12 07 2024-1

Troubleshooting

Problem

Possible cause

Suggested solution

No water production

Water supply turned off

Turn on feed water.

Not enough water production Water supply blocked

Remove blocking.

Feed water valve clogged

Open or unclog valve.

No drain

Clean or replace check valve.

Pump not running

Low feed water pressure

Check source water supply.

No power supply or loose con- Turn on power supply, check

nection

connection.

Transformer burned out

Replace transformer.

Pump is running, but system is Prefilter clogged not producing water

Replace filter cartridges.

Inlet solenoid valve not function- Repair or replace valve. ing

System does not switch off

High-pressure switch not operat- Repair or replace switch. ing

Abnormal pump noise

Prefilter clogged

Replace filter cartridges.

Low feed water pressure

Adjust feed water pressure.

No discharge water

Drain flow restrictor clogged

Replace drain flow restrictor.

Produced water has a bad taste Post/line filter needs replace- Replace filter cartridges. ment

Hoses leaking

Incorrect hose connection

Check/reposition hoses.

Defective or damaged hoses Replace hose section.

https://www.naturewater.eu

Item 64429­64432

Page 13 07 2024-1

Disposal regulations
EU guidelines regarding the disposal of scrap electric appliances (WEEE, 2012/19/EU) were implemented in the law related to electrical and electronic equipment and appliances.
All WilTec electric devices that fall under the WEEE regulations are labelled with the crossed-out wheeled waste bin logo. This logo indicates that this electric equipment must not be disposed with the domestic waste.
The company WilTec Technik GmbH has been registered in the German registry EAR under the WEEEregistration number DE45283704.
Disposal of used electrical and electronic appliances (intended for use in the countries of the European Union and other European countries with a separate collection system for these appliances). The logo on the article or on its packaging points out that this article must not be treated as normal household waste but must be disposed to a recycling collection point for electronic and electrical waste equipment. By contributing to the correct disposal of this article you protect the environment and the health of your fellow men. Environment and health are threatened by inappropriate disposal.
Material recycling helps reduce the consumption of raw materials.
Additional information on recycling this article can be provided by your local community, municipal waste disposal facilities, or the store where you purchased the article.
Address: WilTec Wildanger Technik GmbH
Königsbenden 12 / 28 D-52249 Eschweiler

Important notice:

The reprint or reproduction, even of excerpts, and any commercial use, even in part, of this instruction manual require the written permission of WilTec Wildanger Technik GmbH.

https://www.naturewater.eu

Item 64429­64432

Page 14

07 2024-1

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Naturewater User Manuals