Specifications:

  • Model: NW-4-400ROD
  • Type: 4-stage Reverse Osmosis System
  • Item Number: 64400

Product and Accessories

The product includes:

  • Filter system with six filter cartridges: PP sediment filter (PP), activated-carbon filter (CTO), reverse-osmosis membrane (RO), and activated-carbon post-filter (T-33)
  • Accessories box containing water faucet, three-way valve, three hoses (red, blue, and white), user’s manual, adaptor, and drain clamp

Connection Diagram:

Key components in the connection diagram include Reverse osmosis faucet, Faucet, Dust cover, Filter inserts, Pure water pipe, Drain-heater pipe, Inlet pipe, 3-way ball valve, Tap water line, Filtered water outlet, Current display, Inlet TDS, TDS outlet, Cartridge service life indicator, Capacity display, Low water alarm, Cartridge flushing.

Product Usage Instructions

Safety Instructions:

Before using the product, carefully read and understand the operation instructions provided in the manual. Ensure to follow basic safety precautions to minimize the risk of injury.

Installation:

To install the ball valve and T pieces:

  • Connect the water supply hose to the 3-way ball valve.
  • Connect the ball valve to the pipe and faucet.

To mount the water faucet:

  • Attach the faucet to the underside of the water faucet.
  • Connect the water faucet line to the device.
  • Ensure proper connection of all lines.

Maintenance:

Allow the system to run for more than 90 minutes before conducting any tests. Replace the 3 pre-filters when prompted by the system for optimal performance.

Frequently Asked Questions

Q: How often should I replace the filter cartridges?

A: The system will indicate when to replace the pre-filters. For other cartridges, follow the manufacturer’s recommendations based on usage and water quality.

Q: Can I use this system for well water?

A: It is recommended to test your well water quality first and consult with the manufacturer if the system is suitable for your specific water source.

NW-4-400ROD 4-stage Reverse Osmosis 64400

Illustration similar, may vary depending on model

  • Read and follow the operating instructions and safety information before using for the first time.

  • Technical changes reserved!
    Due to further developments, illustrations, functioning steps, and technical data can differ insignificantly.

  • Updating the documentation
    If you have suggestions for improvement or have found any irregularities, please contact us.

The information contained in this document may alter at any time without previous notice. It is prohibited to copy or spread any parts of this document in any way without prior written allowance. All rights reserved.
The WilTec Wildanger Technik GmbH cannot be held accountable for any possible mistakes in this operating manual, nor in the diagrams and figures shown.
Even though, the WilTec Wildanger Technik GmbH has undergone biggest possible efforts to ensure that the operating manual is complete, faultless, and up to date, mistakes cannot be entirely avoided. If you should find a mistake or wish to make a suggestion for improvement, we look forward to hearing from you.

Send an e-mail to:
[email protected]

or use our contact form:
https://www.wiltec.de/contacts/

The most recent version of this manual in various languages can be found in our online shop via:
https://www.wiltec.de/docsearch

Our postal address is:
WilTec Wildanger Technik GmbH Königsbenden 12 52249 Eschweiler Germany

To return orders for exchange, repair, or other purposes, please use the following address. Attention! To allow for a smooth execution of your complaint or return, it is important to contact our customer service team before returning the goods.

Returns Department
WilTec Wildanger Technik GmbH Königsbenden 28 52249 Eschweiler

E-mail: [email protected]
Tel: +49 2403 55592–0
Fax: +49 2403 55592–15

Introduction

Thank you for purchasing this quality product. To minimise the risk of injury we urge that our clients take some basic safety precautions when using this device. Please read the operation instruc-tions carefully and make sure you have understood its content.
Keep these operation instructions safe.

Safety instructions

  • Clean and replace the filter cartridges regularly.
  • Do not disassemble parts indiscriminately; this can lead to leaks or damage.
  • Do not use power supply units with an unsuitable rated voltage.
  • Disconnect the mains plug and close the water tap before storing the appliance for a longer period.
  • Do not store or use the appliance at an ambient temperature of 0 ℃ or below.
  • Take care when installing or removing the cartridge or moving the appliance.

Other instructions

  • When not in use, interrupt the water supply and close the ball valve to prevent damage from pressure surges. Uncontrolled pressure surges can lead to leaks and damage to the filter hous-ing. We accept no liability for damage caused by pressure surges.
  • In the event of problems, disconnect the appliance from the power and water supply and contact a specialist. Replacing the filters may solve the problem.
  • The appliance vibrates slightly during the filtering process.
  • It is recommended that the cartridges are replaced by a specialist.
  • If the water supply is insufficient, the indicator light lights up yellow and the buzzer sounds for 5 s
  • After 50 operating hours, the indicator lights up green and the buzzer sounds for 10 s. At the same time, the system stops operating and reminds the user to replace the 3 pre-filters. The calculation of the filter service life starts after the system is switched on again.

Note!

  • Before opening the faucet for the first time, make sure that the system is correctly installed and working properly. Rinse the filters for 10–15 min before taking the first glass of water for drinking.
  • Allow the system to run normally for more than 90 min before carrying out a test.

Product and accessories

naturewater-NW-4-400ROD-4-Stage-Reverse-Osmosis-with-LED-Indicator-
fig-1

Drawings illustrating contents of accessories box

naturewater-NW-4-400ROD-4-Stage-Reverse-Osmosis-with-LED-Indicator-
fig-2

Connection diagram

naturewater-NW-4-400ROD-4-Stage-Reverse-Osmosis-with-LED-Indicator-
fig-3

Installation

Installing the ball valve and T pieces

  • Install the T piece and the 3-way ball valve according to the instructions.
  • Wrap the thread of the 3-way ball valve and T piece with adhesive rubber.
  • Connect the water supply line (⅜″, white) from the device to the feed-water valve.
  • Install the 3-way ball valve to the T piece, then connect it to the water source.naturewater-NW-4-400ROD-4-Stage-Reverse-Osmosis-with-LED-Indicator-fig-4

Mounting the water faucet

  • Chose a suitable spot near your washbasin to install the water faucet.
  • Drill a 12-mm diameter hole into the worktop.
  • Install the washers, plates, gaskets, and nuts in the order shown and tighten them on the worktop.
  • Fix the reverse-osmosis water line (¼″, blue) to the un-derside of the water faucet, then connect the line to the device. Attention! Make sure that the lines have been connected properly.

Installing the drain clamp

  • Install the drain clamp to the drainpipe above the syphon and tighten it.
  • Using the drain clamp as a guide, drill a 6-mm hole large enough to feed the ¼-inch pipe through one side of the drainpipe. Do not drill through both sides!
  • Connect the drainpipe (¼″, red) from the device to the drain clamp.

Attention!

  • Cut the hoses cleanly and at right angles. Failure to do so will result in poor connections and possible water leaks.
  • The lowest point of the pipe should be the point where the drain clamp is connected.
  • The pipe should not sag, as this might lead to excessive noise when the wastewater flows to the drain.

Drain-clamp assembly

naturewater-NW-4-400ROD-4-Stage-Reverse-Osmosis-with-LED-Indicator-
fig-6

Instructions for initial commissioning

  1. Connect the reverse osmosis system to the adapter, then the power indicator light lights up, the buzzer sounds three times, the device rinses for 90 s and the rinsing symbol flashes
  2. The reverse osmosis system starts producing water and the integrated computer displays the TDS value, cartridge life and operating indicator in real time. All symbols go out when the water tank is full.
  3. The water reservoir symbol flashes and buzzes 10 times if there is not enough water or the water pressure is too low. The machine rinses for 5 s if there is enough water or the water pressure is too high. 4.
  4. The machine stops producing water and issues a warning message. All symbols flash and the buzzer sounds 30 times after 6 hours of uninterrupted operation or if a water leak is detected.

Note! During normal operation, you should drain water for 10–15 min to rinse the cartridges when using the machine for the first time.\

Replacing the cartridges and maintaining the device

Recommended replacement intervals for cartridges

__

Stages

| __

Filter cartridges

| __

Function

| Service life (guide value) (months)
---|---|---|---
1st stage| PP sediment filter| Removes larger suspended particles from the water.| 3–6
__

2nd stage

| __

CTO activated-carbon filter

| Effectively remove chlorine, bind colour and odours from the water to extend the service life of the reverse-osmosis mem- brane.| __

3–6

__

3rd stage

| Reverse-osmosis mem- brane| Filters the finest pollutants from the water and allows only pure water to pass

through.

| __

12–24

4th stage| Activate-carbon post-fil- ter| Purifies the water again and ensures a good flavour.| 3–6

Reminder to replace the cartridges
There are 6 fields that display the current service life of the corresponding filter cartridge. All displays go out when the service life of the filter has expired.

naturewater-NW-4-400ROD-4-Stage-Reverse-Osmosis-with-LED-Indicator-
fig-6

Note!

1.The actual service life of the filter can be influenced by the region, the water quality, the seasons and the daily water consumption, so that the time period for the filter change can vary.
2.Please replace regularly.

Resetting the cartridges
Press and hold the selection button for 3 s to enter selection mode. Then press Select to select the cartridge that needs to be replaced and then press the Reset button. Selection mode is cancelled automatically if no operation is performed within 5 s.

Replacing the cartridge

Please switch off the water and switch off the power before replacing the cartridges

naturewater-NW-4-400ROD-4-Stage-Reverse-Osmosis-with-LED-Indicator-
fig-8

Technical specifications

Quality of feed water Municipal tap water
Pure water flow rate (ℓ⁄min) 1.2
Temperature of feed water (℃) 5–45
TDS value of feed water (ppm) ≤ 250
Chlorine content of feed water (ppm) ≤ 0.2
Rejection (%) 90–99
Feed-water pressure (bar) 1–4
Stability against electric shocks Type 2

Process chart of water treatment

naturewater-NW-4-400ROD-4-Stage-Reverse-Osmosis-with-LED-Indicator-
fig-9

Wiring chart

naturewater-NW-4-400ROD-4-Stage-Reverse-Osmosis-with-LED-Indicator-
fig-10

Troubleshooting

Problem Possible cause Suggested solution
Water pump out of order, system does not work Insufficient feed water
pressure Increase feed water pressure.
No power or power failure Switch on.
High-pressure switch defective Replace high-pressure switch.
Pump blocked, adapter fuse blown Replace adapter and repair water pump.
Water pump is running, but system is not working Reverse osmosis membrane
clogged Replace reverse osmosis mem- brane.
Pressure loss of the water pump Repair the water pump.
High TDS value The TDS value of the feed water is too high or the system has
not been used for a long time Open the faucet to draw pure water for a while.
Service life of the cartridge has been exceeded Replace cartridge.
Constantly flowing water when machine is in standby Solenoid valve for water
inlet dam- aged Replace feed water solenoid valve.
Cannot stop working when the pressure tank is full or is started repeatedly
High pressure switch is damaged Repair or replace high-pressure switch.
Check valve damaged Replace check valve.

Disposal regulations

EU guidelines regarding the disposal of scrap electric appliances (WEEE, 2012/19/EU) were imple-mented in the law related to electrical and electronic equipment and appliances.
All WilTec electric devices that fall under the WEEE regulations are labelled with the crossed-out wheeled waste bin logo. This logo indicates that this electric equipment must not be disposed with the domestic waste.
The company WilTec Technik GmbH has been registered in the German registry EAR under the WEEE-registration number DE45283704.

Disposal of used electrical and electronic appliances (intended for use in the countries of the European Union and other European countries with a separate collection system for these appliances).
The logo on the article or on its packaging points out that this article must not be treated as normal household waste but must be disposed to a recycling collec-tion point for electronic and electrical waste equipment. By contributing to the correct disposal of this article you protect the environment and the health of your fellow men. Environment and health are threatened by inappropriate disposal.

Material recycling helps reduce the consumption of raw materials.
Additional information on recycling this article can be provided by your local community, municipal waste disposal facilities, or the store where you purchased the article.

Address:
WilTec Wildanger Technik GmbH Königsbenden 12 / 28 D-52249 Eschweiler

Important notice:
The reprint or reproduction, even of excerpts, and any commercial use, even in part, of this instruction manual require the written permission of WilTec Wildanger Technik GmbH.

https://www.naturewater.eu

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Naturewater User Manuals

Related Manuals