Naturewater 50811 Booster Pump Instruction Manual

June 3, 2024
Naturewater

Naturewater logo 50811 Booster Pump
Instruction ManualNaturewater 50811 Booster Pump

50811 Booster Pump

Instruction Manual
Booster Pump
50811, 50812, 51784, 51785, 62789, 62790, and 62791
Illustration similar, may vary depending on model
Read and follow the operating instructions and safety information before using for the first time.
Technical changes reserved!
Illustrations, functional steps, and technical data may deviate insignificantly due to continuous further developments.
Updating the documentation
If you have suggestions for improvement or have found any irregularities, please contact us.
The information contained in this document may alter at any time without prior notice. No part of this document may be copied or otherwise duplicated without prior written consent. All rights reserved.
WilTec Wildanger Technik GmbH cannot be held liable for any possible mistakes in this operating manual, nor in the diagrams and illustrations shown. Although WilTec Wildanger Technik GmbH has made every possible effort to ensure that this operating manual is complete, accurate, and up-to-date, errors cannot be ruled out entirely. If you have found an error or wish to suggest an improvement, we look forward to hearing from you.
Send us an e-mail to: service@wiltec.info or use our contact form: https://www.wiltec.de/contacts/
The most recent version of this manual in several languages can be found in our online shop: https://www.wiltec.de/docsearch
Our postal address is:
WilTec Wildanger Technik GmbH Königsbenden
12 52249 Eschweiler Germany
To return your goods for exchange, repair, or other purposes, please use the following address.
Attention! To allow for a trouble-free complaint or return, it is important to contact our customer service team before returning your goods.
Retourenabteilung
WilTec Wildanger Technik GmbH Königsbenden 28 52249
Eschweiler Germany
E-mail: service@wiltec.info
Phone: +49 2403 55592–0
Fax: (+49 2403 55592–15)

Introduction

Thank you for choosing to purchase this quality product. To minimise the risk of injury, we ask you to always take some basic safety precautions when using this product. Please read this operating manual carefully and make sure that you understand it. Keep these operation instructions in a safe place.

General remarks

A booster pump is used when the normal water pressure feeding a reverse- osmosis system requires increase. The efficiency of the booster pump depends on the intake pressure of the supplied water. For correct operation, a typical reverse-osmosis system requires a water pressure of a minimum of 3.5 bar (50 psi). In case the water pressure is below 3.5 bar (50 psi), the system produces a smaller quantity of water with a lower quality.
Note! Our booster pumps have a pressure regulation screw. The pump is tested in the factory and set to ideal values. We wish to advise you not to modify these values, which could affect the output of the pump.
Naturewater 50811 Booster Pump fig 8

Name Name
1 Transformer 4 High-pressure switch
2 Solenoid valve 5 Low-pressure switch
3 Pump
  1. The booster system (A) is ideally suitable for home use. It has a high-quality non-stop pump that supplies a constant water flow to the diaphragm and operates quietly. The pump has a ⅜″ connector (B, C); nevertheless, a ¼″ quick coupling (not included) can be used, too. These quick couplings can be screwed off or replaced if necessary. The pump is available with a large variety of motor voltages, delivery heights, and configurations.
  2. Please observe the figg. 1 and 2 regarding high-pressure switch (E), low-pressure switch (F), solenoid valve or four-way valve (D), transformer (G), etc.

Technical specifications

Structure, size, and tolerance (values in mm)Naturewater 50811 Booster Pump
fig 7

Model SKU Properties
LFP1050 W 50811 Maximum amperage and voltage: 1 A, 24 V

Threaded pipe: ⅜″
Metal base 190ℓ ⁄day (50 gpd)

Naturewater 50811 Booster Pump fig 6

Model SKU Properties
LFP1100 W 62789 Maximum amperage and voltage: 1.4 A, 24 V

Threaded pipe: ⅜″

Metal base

378 ℓ⁄day  (100 gpd)

Naturewater 50811 Booster Pump fig 5

Model SKU Properties
LFP1200 W-A 50812 Maximum amperage and voltage: 2.5 A, 24 V

Threaded pipe: ⅜″ Metal base
750 ℓ⁄day  (200 gpd)

Naturewater 50811 Booster Pump fig 4

Model SKU Properties
LFP1300 W-A 51784 Maximum amperage and voltage: 2.8 A, 24 V

Threaded pipe: ⅜″
Metal base 1135 ℓ⁄day  (300 gpd)

Naturewater 50811 Booster Pump fig 3

Model SKU Properties
LFP1400– 2 W 51785 Maximum amperage and voltage: 4.0 A, 24 V

Threaded pipe: ⅜″
Metal base 1514 ℓ⁄day  (400 gpd)

Naturewater 50811 Booster Pump fig 2

Model

| SKU| Properties
---|---|---
LFP1500 W| 62790| Maximum amperage and voltage: 4.2 A, 24 V Threaded pipe: ⅜″
Metal base 1893 ℓ⁄day  (500 gpd)

Naturewater 50811 Booster Pump fig 1

Model SKU Properties
LFP1600 W 62791 Maximum amperage and voltage: 4.5 A, 24 V

Threaded pipe: ⅜″
Metal base 2271 ℓ⁄day  (600 gpd)

Regulations for waste disposal

The Waste Electrical and Electronic Equipment irective (WEEE irective, 2012/19/EU) of the EU was implemented in the German law related to electrical and electronic equipment and appliances.
All WilTec electric devices that fall under the WEEE directive are labelled with the symbol of a crossedout wheeled rubbish bin.
This symbol indicates that this electric device must not be disposed of with the domestic waste.
WilTec Technik GmbH is registered with the German registration authority EAR (Stiftung ElektroAltgeräte-Register) under the WEEE-registration number E45283704.
Disposal of used electrical and electronic devices (intended for use in the countries of the European Unionand other European countries with a separate wastecollection system for these devices).
The symbol on the packaging or the product itself indicates that this product must not be  treated as normadomestic waste butmust be disposed
of at a recyclingcollection station for electrical and electronic waste.
By disposing of this product correctly, you contribute tothe protection of the environment and the health
of yourfellow people. Inappropriate disposal threatens the environment and health.

Material recycling helps to reduce the consumption of raw materials.
Additional information about the recycling of this product can be provided by your local commune, the municipal waste disposal facilities, or the store where you purchased the product.
Address:
WilTec Wildanger Technik GmbH
Königsbenden 12 / 28
52249 Eschweiler Germany
Important Note:
Reproduction and any commercial use (of parts) of this operating manual, requires a written permission of WilTec Wildanger Technik GmbH.

https://www.naturewater.eu
Article 50811, 50812, 51784, 51785, 62789–62791

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Naturewater User Manuals

Related Manuals