DURASTAR DR1L24A24 24,000 Btu/H Sirius Heat Air Handler System User Guide
- September 3, 2024
- DURASTAR
Table of Contents
DURASTAR DR1L24A24 24,000 Btu/H Sirius Heat Air Handler System
Specifications
- Indoor Unit (IDU): DRAM24F1A
- Outdoor Unit (ODU): DRA1H24S1A
- Product Features: SIRIUS HEAT AIR HANDLER SYSTEM
- Efficiency Data:
- SEER: 18.4
- EER: 11.7
- HSPF: 9.3
- COP at 47°F: 3.50
- COP at 17°F: 2.39
- COP at 5°F: 1.90
- System Data:
- Refrigerant Type: R-410A
- Refrigerant Charge: 91.71 oz.
- Design Pressure (PSIG): Indoor – 550, Outdoor – 340
- Coil Coating: Golden Fin Coating
- Capacities:
- Cooling Capacity: Rated at 95°F – 23000 BTU/hr, Maximum at 109°F – 26000 BTU/hr
- Heating Capacity: Rated at 5°F – 16900 BTU/hr, Maximum at 47°F – 21200 BTU/hr, Maximum at 17°F – 5600 BTU/hr, Maximum at 5°F – 29000 BTU/hr
Product Usage Instructions
- Installation
- Follow the installation guidelines provided in the user manual for proper setup of the indoor and outdoor units.
- Operation
- Use the wired remote DRSTAT100 to control the system.
- Select the desired mode (cooling or heating) and set the temperature using the remote.
- Maintenance
- Regularly clean the air filters and ensure proper airflow for efficient operation.
- Schedule annual maintenance checks by a qualified technician to keep the system in good condition.
FAQs
- Q: What is the recommended voltage for the system?
- A: The system operates on 208-230V, 1 Phase, 60 Hz voltage.
- Q: How do I adjust the fan speed?
- A: The fan speed can be adjusted using the wired remote control provided with the system.
DIFFERENT MODEL
PRODUCT FEATURES
- High heating capacity at 0°F
- High-efficiency constant volume variable speed motor
- Multi-position installation: horizontal (right or left), vertical (up or down)
- Built-in dehumidifier, humidifier, and IAQ ports
- All aluminum coil
- Anti-corrosive coil fin coating
- Low ambient heating down to -22oF
- Low ambient cooling down to 5oF
- Included base pan heater
- Refrigerant leak detection
- DRSTAT100 programmable thermostat included
- Automatic airflow configuration technology
- Multiple operation modes (Cool, Heat, Aux, Dry, Fan, Auto)
- 24V thermostat compatible
- Optional electric heat (not included)
EFFICIENCY DATA
SEER2| 18.4
EER2| 11.7
HSPF2| 9.3
COP at 47oF2| 3.50
COP at 17oF4| 2.39
COP at 5oF5| 1.90
SYSTEM DATA
Refrigerant Type| R-410A
Refrigerant Charge (oz.)| 91.71
Design Pressure (PSIG)| 550/340
Indoor/ Outdoor Coil Coating| Golden Fin Coating
CAPACITIES
Cooling Capacity (BTU/hr)| Rated at 95oF1| 23000
Maximum at 109oF| 22000
Maximum at 5oF3| 24800
Minimum| 7500
Maximum| 26000
Heating Capacity (BTU/hr)| Rated at 47oF2| 26000
Rated at 17oF4| 16900
Rated at 5oF5| 21200
Minimum| 5600
Maximum| 29000
LINE SET REQUIREMENTS
Connection Type| Flare
Liquid (Insulated)| Ø3/8″ (Ø9.5mm)
Gas (Insulated)| Ø5/8″ (Ø15.9mm)
Pre-Charge Length| 25′
Minimum Length| 10′
Maximum Length| 98′
Maximum Height Differential| 66′
Additional Refrigerant (oz./ft)| 0.16
OUTDOOR UNIT
Unit Dimensions
| Width| 37-1/4″
Depth| 16-3/16″
Height| 31-15/16″
Carton Dimensions
| Width| 42-15/16″
Depth| 19-11/16″
Height| 36-13/16″
Net Weight| 134.5 lbs.
Gross Weight| 144.5 lbs.
Cooling Operating Temperature| 5°F – 122°F
Heating Operating Temperature| -22°F – 75°F
Voltage/Phase/Frequency| 208-230V, 1 Phase, 60 Hz
Voltage Range| 187-253V
Recommended Breaker (Amps)| 35
Minimum Circuit Ampacity (Amps)| 25
Communication Wire Size| 14*4 AWG Stranded
Rated Current – Cooling (Amps)1| 8.7
Rated Current – Heating (Amps)2| 9.3
Fan Motor RLA (Amps)| 0.8
Fan Motor Output (Watt)| 80
Sound Pressure (dB(A))| 62
INDOOR UNIT
Unit Dimensions| Width| 17-1/2″
Depth| 21″
Height| 45″
Carton Dimensions| Width| 26-9/16″
Depth| 20-7/8″
Height| 48-5/8″
Net Weight| 106.7 lbs.
Gross Weight| 127.2 lbs
Blower Motor Type| Constant Volume Variable Speed
Indoor Unit Air Flow (CFM)| Low| 629
Medium| 694
High| 759
Turbo| 824
Drain Port Size| 3/4″
Moisture Removal (Pints/day)| 100
Recommended Breaker (Amps)| 15
Indoor Fan Motor RLA (Amps)| 2.0
Sound Pressure (dB(A))| Low| 38
Medium| 39
High| 41
Static Pressure Range 6 (in. wg.)| 0 – 0.8
Filter Dimensions (WDH) (in.)| 16 x 20 x 1
COMPRESSOR
Type| DC Inverter Twin Rotary
Rated Current (RLA) (Amps)| 17.1
Oil Type| Ester Oil VG74
Oil Charge (oz.)| 21 (620ml)
AHRI-rated data is taken at a fixed compressor speed.
- AHRI Rated at 95°F (AFull).
- AHRI Rated at 47°F (H1Full).
- Maximum Capacity: Indoor 80°F DB, 67°F WB // Outdoor 5°F DB, 4°F WB
- AHRI Rated Capacity at 17°F (H32)
- AHRI Rated Capacity at 5°F (H42)
- Static pressure at full required airflow for AHRI testing is 0.5 in.WG.
Dimensions
Clearances
Auxiliary Electric Heaters (Optional)
Model | Size |
---|---|
DRHTR05BRKA | 5kW |
DRHTR08BRKA | 8kW |
DRHTR10BRKA | 10kW |
DRHTR15BRKA | 15kW |
Clearances
Dimensions
Illustrations in this document are for explanatory purposes. The actual shape
of your mini-split equipment may vary slightly. Specifications are subject to
change without notice. © 2024 Ferguson Enterprises LLC
www.durastar.com.
Form No. V1.1_02.24