DURASTAR DRAS12F1B Floor Mounted Indoor Unit Split Style Air Conditioner Instruction Manual

June 13, 2024
DURASTAR

DURASTAR DRAS12F1B Floor Mounted Indoor Unit Split Style Air Conditioner

Product Information

  • Model Number:
    SPLIT-STYLE AIR CONDITIONER DRAS12F1B

  • Serial Number:
    [Serial Number]

  • Purchase Date:
    [Purchase Date]

  • Installing Contractor Company Name:
    [Installing Contractor Company Name]

Product Usage Instructions

Important Safety Precautions

  • Read and follow all safety information provided in the manual to avoid damage or injury.
  • Handle the air conditioner properly to prevent electric shock.

Operating Temperatures

Mode Indoor Air Temperature Outdoor Air Temperature
COOL mode [Temperature Range] [Temperature Range]
HEAT mode [Temperature Range] [Temperature Range]
DRY mode [Temperature Range] [Temperature Range]

Note: Keep the room’s relative humidity below 80% to prevent condensation. Set the vertical airflow louver to its maximum angle and the fan to HIGH to help prevent condensation from forming and dripping.

Accessories

The air conditioning system comes with the following accessories:

  • Accessory Manual – Quantity 1-2
  • Remote Control – Quantity 1
  • Drain Pipe – Quantity 1
  • Insulation Sleeve – Quantity 1
  • Worm Clamp – Quantity 2
  • Battery – Quantity 2
  • Drain Joint – Quantity 1
  • Drain Joint Seal – Quantity 1
  • Remote Control Holder – Quantity 1
  • Copper Nut – Quantity 2
  • Mounting Screw Transfer Connector (9.52-12.7) – Quantity 1
  • Mounting Plate or Brackets (Depends on Model) – Quantity 1-2

Tools Needed

The following tools are required for installation:

  • [Tool 1]
  • [Tool 2]
  • [Tool 3]

Parts Identification

Note: The installation must be performed in accordance with the required local and national standards. The installation may be slightly different in different markets.

Indoor Unit:

  • Top Air Outlet and Louver
  • Air Inlet
  • Control Panel
  • Bottom Air Outlet and Louver
  • Refrigerant Pipes and Signal Cable
  • Drain Hose

Outdoor Unit:

  • Air Inlets
  • Signal Cable, Refrigerant Pipes, and Drain Pipe
  • Wiring Terminal
  • Air Outlet
  • Valve Cover

TIP
Capture relevant information about your Durastar mini-split equipment before it is installed and write it above for future reference.

INTRODUCTION

To better serve you, please do the following before contacting customer service:

  • If you received a damaged product, immediately contact the retailer or dealer that sold you the product.
  • Read and follow this owner’s manual carefully to help you use and maintain your air conditioner.
  • Read the troubleshooting section of this manual as it will help you diagnose and solve common issues.
  • Visit us on the web at www.durastar.com to download product guides and up-to-date information.
  • If you need warranty service, our friendly customer service representatives are available via email at questions@durastar.com or by telephone at 1-888-320-0706.

WARNINGS

Symbols Used in This Manual

The warning symbol indicates cautionary information for the user. Extra care and precautions should be taken to ensure the user’s safety.

The pencil indicates any manufacturer notes relating to surrounding content. These may include further clarifications or call-outs.

A light bulb symbol indicates suggested manufacturer tips for the user to get the most out of the Durastar equipment and to accommodate the best user experience.

IMPORTANT SAFETY PRECAUTIONS

Improper handling can cause serious damage or injury. Please read the following safety information in its entirety.
Operation, Cleaning, and Maintenance Safety Precautions

  • Children and people with reduced physical, sensory, or mental capabilities, or lack of experience and knowledge, should only use this air conditioner if they are given supervision or instructions concerning use of the air conditioner in a safe way and understand the hazards involved.
  • Children should not play with the air conditioner.
  • Never stick fingers or any other body parts into the air conditioner openings. The internal fan may be rotating at high speeds, and may result in injury.
  • After removing the filter, do not touch the fins in order to avoid injury.
  • Maintenance must be performed by qualified professionals. Otherwise, you may experience personal injury or damage to the air conditioner and surrounding property.
  • Do not repair the air conditioner by yourself. It may cause electric shock or damage. Please contact a qualified service representative when you need to repair the air conditioner.
  • Do not block the air outlet or air inlet. This could cause a malfunction.
  • Do not spill water on the remote control as this can permanently damage the remote.
  • If the below problems occur, please turn off the air conditioner and disconnect power at the circuit breaker immediately. Then contact your dealer or a qualified professional for service.
  • The power cord is overheating or damaged.
  • There is an abnormal sound during operation.
  • The circuit breaker trips frequently.
  • The air conditioner gives off a burning smell.
  • The indoor unit is leaking.
  • If the air conditioner operates under abnormal conditions, it may cause malfunctions, electric shock, or fire hazard.
  • When turning the unit on or off via the emergency operation switch, press the switch with an insulated object other than metal.
  • Do not step on the top panel of the unit, or put heavy objects on the top panel. This could cause damage or personal injury.
  • Cleaning and user maintenance should not be performed by children without supervision.
  • Do not spray water on the indoor unit. This could cause electric shock or a unit malfunction.
  • Do not use flammable materials such as hair spray, lacquer, or paint near the air conditioner as they may catch fire.
  • Do not operate the air conditioner in places near combustible gases. Emitted gases may collect around the air conditioner and cause an explosion.
  • Do not use fire or a hair dryer to dry the filter. This could cause a deformation or fire hazard.
  • Do not wash the air conditioner with water as this could cause an electric shock.
  • Disconnect the power supply by turning it off at the circuit breaker when cleaning the air conditioner. Otherwise, you could risk electric shock.

Electrical Safety

  • Only use the specified power cord. If the power cord is damaged, it must be replaced by the manufacturer, its service agent, or similarly qualified persons in order to avoid a hazard.

  • Keep the power plug clean. Remove any dust or grime that accumulates on or around the plug. Dirty plugs can cause fire or electric shock.

  • Do not pull the power cord to unplug unit. Hold the plug firmly and pull it from the outlet. Pulling directly on the cord can damage it, which can lead to fire or electric shock.

  • Do not connect the air conditioner to a multi-purpose socket. Doing so could cause a fire hazard.

  • Do not modify the length of the power supply cord or use an extension cord to power the unit.

  • If the supply cord is damaged, it must be replaced by the manufacturer, a service agent, or a similarly qualified person in order to avoid a safety hazard.

  • Do not share the electrical outlet with other appliances. Improper or insufficient power supply can cause fire or electrical shock.

  • The product must be properly grounded at the time of installation, or electrical shock may occur.

  • For all electrical work, follow all local and national wiring standards and regulations. Connect cables tightly, and clamp them securely to prevent external forces from damaging the terminal. Improper electrical connections can overheat and cause fire, and may also cause shock. All electrical connections must be made according to the Electrical Connection Diagram located on the panels of the indoor and outdoor units.

  • All wiring must be properly arranged to ensure that the control board cover can close properly.
    If the control board cover is not closed properly, it can lead to corrosion and cause the connection points on the terminal to heat up, catch fire, or cause electrical shock.

  • The air conditioner’s circuit board (PCB) is designed with a fuse to provide overcurrent protection. The specifications of the fuse are printed on the circuit board.

Installation Safety

  • Installation must be performed by an authorized dealer or specialist. Improper installation can cause water leakage, electrical shock, or fire. (In North America, installation must be performed in accordance with NEC and CEC requirements by authorized personnel only.)
  • Installation must be performed according to the installation instructions. Improper installation can cause water leakage, electrical shock, or fire.
  • This air conditioner shall be installed in accordance with national and local wiring regulations.
  • Contact an authorized service technician for repair or maintenance of this unit.
  • Only use the included accessories, parts, and specified parts for installation. Using nonstandard parts can cause water leakage, electrical shock, fire, and can cause the unit to fail.
  • Install the unit in a firm location that can support the unit’s weight. If the chosen location cannot support the unit’s weight, or the installation is not done properly, the unit may fall and cause serious injury and damage.
  • Install drainage piping according to the instructions in the installation manual. Improper drainage may cause water damage to your home and property.
  • For units that have an auxiliary electric heater, do not install the unit within 3 feet (1 meter) of any combustible materials.
  • Do not install the unit in a location that may be exposed to combustible gas leaks. If combustible gas accumulates around the unit, it may cause a fire.
  • Do not turn on the power until all work has been completed.
  • When moving or relocating the air conditioner, consult experienced service technicians for disconnection and re-installation of the unit.

Additional Precautions

  • Turn off the air conditioner and disconnect the power if you are not going to use it for a long time.
  • Turn off and unplug the unit during storms.
  • Make sure that water condensation can drain unhindered from the unit.
  • Do not operate the air conditioner with wet hands. This may cause electric shock.
  • Do not use this device for any other purpose than its intended use.
  • Do not climb onto or place objects on top of the outdoor unit.
  • Do not allow the air conditioner to operate for long periods of time with doors or windows open, or if the humidity is very high..

OPERATING TEMPERATURES

Your air conditioner is designed to operate in the following indoor and outdoor temperatures.
When your air conditioner is used outside of the following temperature ranges, certain safety features may activate and turn off the unit to protect it from damage.

TEMPERATURE RANGES

  COOL mode HEAT mode DRY mode
Indoor Air Temperature 62°F – 90°F

(17°C – 32°C)

| 32°F – 86°F

(0°C – 30°C)

| 50°F – 90°F

(10°C – 32°C)

Outdoor Air

Temperature

| 5°F – 122°F

(-15°C – 50°C)

| -13°F – 86°F*

(-25°C – 30°C)*

| 32°F – 122°F

(0°C – 50°C)

The minimum operating temperature depends on the outdoor unit. Low ambient models have a minimum operating temperature in heat mode of -22°F (-30°C).

To further optimize the performance of your unit, do the following:

  • Keep doors and windows closed.
  • Limit energy usage by using TIMER ON and TIMER OFF features.
  • Do not block air inlets or outlets.
  • Regularly inspect and clean air filters.

NOTE

  • Your Durastar air conditioner’s outdoor unit is equipped with a base pan heater, allowing it to continue to operate at freezing temperatures as low as -22°F (-30°C). When outdoor air temperatures are at or below 32°F (0°C), we strongly recommend keeping the unit plugged in at all times to ensure smooth ongoing performance.
  • Keep the room’s relative humidity below 80%. If the air conditioner operates in excess of this, the surface of the air conditioner may attract condensation. To help prevent condensation from forming and dripping, set the vertical airflow louver to its maximum angle (vertically to the floor) and set the fan to HIGH.

ACCESSORIES

INCLUDED INSTALLATION ACCESSORIES
The air conditioning system comes with the following accessories.

DURASTAR-DRAS12F1B-Floor-Mounted-Indoor-Unit-Split-Style-Air-Conditioner-
FIG- \(4\)

FIELD SUPPLIED INSTALLATION ACCESSORIES
The following installation accessories are required and must be purchased separately.

  • Refrigerant piping (line set)
  • Indoor and outdoor connection wire
  • Outdoor power supply cord
  • Drain pipe
  • Pipe and cable wrapping tape
  • Wall hole sleeve and cover
  • Putty
  • Wiring u-lugs

TOOLS NEEDED
The following tools are required for installation.

  • Phillips screwdriver
  • Drill with 2 1/2″ or 3 1/2″ (indoor unit model depending) core bit
  • Vacuum pump
  • HVAC manifold gauge set
  • Refrigerant leak detector
  • Copper pipe cutter
  • Flaring tool
  • Burr reamer
  • Crescent or spanner wrench
  • Hexagonal wrench set
  • Torque wrench
  • Multimeter
  • Electroprobe
  • Level
  • Hammer
  • Wire strippers
  • Wire crimper

PARTS IDENTIFICATION

NOTE
The installation must be performed in accordance with the required local and national standards. The installation may be slightly different in different markets.

DURASTAR-DRAS12F1B-Floor-Mounted-Indoor-Unit-Split-Style-Air-Conditioner-
FIG- \(5\)

NOTE
Illustrations in this manual are for explanatory purposes. The actual shape of your mini-split equipment may vary slightly.

INSTALLATION OVERVIEW – INDOOR UNIT

DURASTAR-DRAS12F1B-Floor-Mounted-Indoor-Unit-Split-Style-Air-Conditioner-
FIG- \(6\)

INDOOR UNIT INSTALLATION

STEP 1: SELECT INSTALLATION LOCATION
Before installing the indoor unit, you must choose an appropriate location. The following standards should be met for an appropriate location for the unit:

  • Good air circulation
  • Convenient drainage
  • Noise from the unit will not disturb other people
  • Firm and solid – the location will not vibrate
  • Strong enough to support the weight of the unit
  • A location at least three feet (one meter) from all other electrical devices (e.g., TV, radio, computer)

DO NOT install unit in the following locations:

  • Near any source of heat, steam, or combustible gas
  • Near flammable items such as curtains or clothing
  • Near any obstacle that might block air circulation
  • Near a doorway
  • In a location subject to direct sunlight

Refer to the following diagrams to ensure proper distance from walls and ceiling:

DURASTAR-DRAS12F1B-Floor-Mounted-Indoor-Unit-Split-Style-Air-Conditioner-
FIG- \(7\)

NOTE
If there is no pre-existing refrigerant piping, when choosing a location, leave ample room for a wall hole (see Step 3: Drill Wall Hole for Connective Piping) for the signal cable and refrigerant piping that connect the indoor and outdoor units.

STEP 2: MOUNT INDOOR UNIT
Depending on the model, fix the mounting plate or brackets to the wall with tapping screws and mount the unit. The bottom of the unit can touch the floor or remain suspended, but the body must be installed vertically. Refer to the diagrams below.

DURASTAR-DRAS12F1B-Floor-Mounted-Indoor-Unit-Split-Style-Air-Conditioner-
FIG- \(8\)

DURASTAR-DRAS12F1B-Floor-Mounted-Indoor-Unit-Split-Style-Air-Conditioner-
FIG- \(9\)

WARNING
Ensure that the indoor unit is completely level. Improper installation can cause the drain pipe to back up into the unit and water leaks.

STEP 3: DRILL WALL HOLE FOR CONNECTIVE PIPING

  1. Determine the location of the wall hole based on the location of the outdoor unit.
  2. Using a 2 1/2″ (65mm) core drill for units with a gas side connective pipe less than 5/8″ (16mm), or 3 1/2″ (90mm) for units with a gas side pipe greater than or equal to 5/8″ (16mm), drill a hole in the wall. Make sure that the hole is drilled at a slight downward angle, so that the outdoor end of the hole is lower than the indoor end by about 3/16 – 1/4″ (5mm to 7mm). This will ensure proper water drainage.
  3. Place the protective wall hole sleeve (field supplied) into the hole. This protects pipes and cables from sharp edges and will help seal the opening when you finish the installation process. After the sleeve is inserted through the wall, connect the wall hole sleeve cover to the wall sleeve on the outside end. Make sure the cover is flush with the outside wall.

STEP 4: REMOVE FRONT PANEL AND FACE PLATE
To facilitate pipe and cable installation remove the front panel and face plate on the unit.

  1. Slide the two tabs at the top of the front panel inward until they click.
  2. Remove the four screws holding the face plate in place. Open at the bottom 30o and lift off the face plate.
  3. Using a screwdriver, remove the string attached to the front panel. Gently let the front panel fall forward and remove it.

STEP 5: CONNECT DRAIN PIPE
The drain pipe is used to drain condensate water away from the unit. Improper installation may cause leaks and unit or property damage.

  1. Connect the drain pipe (field supplied) to the unit’s connecting port using a metal worm clamp.
    Make sure it secured tightly and can not be easily pulled loose.

  2. Insulate the connecting port and pipe with the accessory sheath (sleeve) provided.DURASTAR-DRAS12F1B-Floor-Mounted-Indoor-Unit-Split-Style-Air-Conditioner-FIG- \(13\)

  3. Install the drain pipe with a downward slope of at least a 1/100 gradient to prevent water from flowing back into the unit. If connecting multiple units, install the pipes as illustrated.

DURASTAR-DRAS12F1B-Floor-Mounted-Indoor-Unit-Split-Style-Air-Conditioner-
FIG- \(14\)

STEP 6: CONNECT SIGNAL CABLE
BEFORE PERFORMING ANY ELECTRICAL WORK, READ THESE REGULATIONS

  1. All wiring must comply with local and national electrical codes and regulations, and must be installed by a licensed electrician.
  2. All electrical connections must be made according to the Electrical Connection Diagram located on the panels of the indoor and outdoor units.
  3. If there is a serious safety issue with the power supply, stop work immediately and contact a licensed electrician. Do not continue with the installation until the safety issue is properly resolved.
  4. Power voltage should be within 90-110% of rated voltage. Insufficient power supply can cause malfunction, electrical shock, or fire.
  5. If connecting power to fixed wiring, install a surge protector and main power switch with a capacity of 1.5 times the maximum current of the unit.
  6. If connecting power to fixed wiring, a switch or circuit breaker that disconnects all poles and has a contact separation of at least 1/8″ (3mm) must be incorporated in the fixed wiring. A qualified technician must use an approved circuit breaker or switch.
  7. Only connect the unit to an individual branch circuit outlet. Do not connect another appliance to that outlet.
  8. Make sure to properly ground the air conditioner.
  9. Every wire must be firmly connected. Loose wiring can cause the terminal to overheat, resulting in product malfunction and possible fire.
  10. Do not let wires touch or rest against refrigerant tubing, the compressor, or any moving parts within the unit.
  11. If the unit has an auxiliary electric heater, it must be installed at least 40″ away from any combustible materials.
  12. To avoid getting an electric shock, never touch the electrical components soon after the power supply has been turned off. After turning off the power, always wait 10 minutes or more before you touch the electrical components.

WARNING
Before performing any electrical or wiring work, turn off the main power to the system.

The signal cable enables communication between the indoor and outdoor units. You must first choose the right cable size before preparing it for connection.

USE THE RIGHT CABLE

  • Indoor Power Cable (if applicable): H05VV-F or H05V2V2-F
  • Outdoor Power Cable: H07RN-F
  • Signal Cable: H07RN-F

CABLE SIZING
Use a minimum of 16 AWG for power and signal cables connected to and between the indoor and outdoor units.

Choose the correct size of cable
The size of the power supply cable, signal cable, fuse, and switch needed is determined by the maximum current of the unit. The maximum current is indicated on the nameplate located on the side panel of the unit. Refer to this nameplate to choose the right cable, fuse, or switch.

Wiring the Indoor Unit (see diagram on next page)

  1. Prepare the cable for connection:
    • Using wire strippers, strip the jacket from both ends of the cable to reveal about 6″ of the wires.
    • Strip the insulation from the ends of the wires.
    • Using a wire crimper, crimp u-lugs to the ends of the wires.
  2. Rotate the sensor bracket upward then remove the electrical box cover.
  3. Unscrew the cable clamp below the terminal block and place it to the side.
  4. Refer to the wiring diagram on the control box cover and connect the u-lugs to the terminal block. Firmly screw the u-lug of each wire to its corresponding terminal.
  5. After checking to make sure every connection is secure, use the cable clamp to fasten the signal cable to the unit. Screw the cable clamp down tightly.
  6. Replace the control box lid.

DURASTAR-DRAS12F1B-Floor-Mounted-Indoor-Unit-Split-Style-Air-Conditioner-
FIG- \(15\)

WARNING
All wiring must be performed strictly in accordance with the wiring diagram located on the inside of the control box lid.

STEP 7: PREPARE REFRIGERANT PIPING

  1. If pre-existing refrigerant piping is already embedded in the wall, begin the outdoor unit installation. Refer to the Refrigerant Piping Connections section of the outdoor unit’s installation manual for detailed instructions.
  2. If there is no pre-existing piping, connect the indoor unit’s refrigerant piping to the connective piping that will join the indoor and outdoor units. Refer to the Refrigerant Piping Connections section of the outdoor unit’s installation manual for detailed instructions.

STEP 8: WRAP PIPES AND CABLE
Before passing the refrigerant piping, drain pipe, and the signal cable through the wall hole, you must bundle them together to save space, protect them, and insulate them.

  1. Bundle the drain pipe, refrigerant pipes, and signal cable as shown below:
    NOTE

    • The drain pipe MUST be at the bottom of the bundle. Putting the drain pipe at the top of the bundle can cause the drain pan to overflow, which can lead to fire or water damage.
    • DO NOT intertwine the signal cable with any of the other wires while bundling these items together.
  2. Using adhesive vinyl tape, attach the drain pipe to the underside of the refrigerant pipes.

  3. Using insulation tape, wrap the signal wire, refrigerant pipes, and drain pipe tightly together. Double-check that all items are bundled.

NOTE
When wrapping the bundle, keep the ends of the piping unwrapped. You need to access them to test for leaks at the end of the installation process (refer to Electrical and Gas Leak Checks section of the outdoor unit’s installation manual).

TROUBLESHOOTING

SAFETY PRECAUTIONS
If ANY of the following conditions occurs, turn off your unit immediately!

  • The power cord is damaged or abnormally warm
  • You smell a burning odor
  • The unit emits loud or abnormal sounds
  • A power fuse blows or the circuit breaker frequently trips
  • Water or other objects fall into or out of the unit

DO NOT ATTEMPT TO FIX THESE YOURSELF! CONTACT AN AUTHORIZED SERVICE PROVIDER IMMEDIATELY!

COMMON ISSUES
The following problems are not a malfunction and in most situations will not require repairs.

ISSUE POSSIBLE CAUSES
Unit does not turn on when pressing ON/OFF button The Unit has

a 3-minute protection feature that prevents the unit from overloading. The unit cannot be restarted within three minutes of being turned off.
The unit changes from COOL/HEAT mode to FAN mode| The unit may change its setting to prevent frost from forming on the unit. Once the temperature increases, the unit will start operating in the previously selected mode again.
The set temperature has been reached, at which point the unit turns off the compressor. The unit will continue operating when the temperature fluctuates again.
The indoor unit emits white mist| In humid regions, a large temperature difference between the room’s air and the conditioned air can cause white mist.
Both the indoor and outdoor units emit white mist| When the unit restarts in HEAT mode after defrosting, white mist may be emitted due to moisture generated during the defrosting process.
The indoor unit makes noises| A rushing air sound may occur when the louver resets its position.
A squeaking sound may occur after running the unit in HEAT mode due to expansion and contraction of the unit’s plastic parts.
Both the indoor unit and outdoor unit make noises| Low hissing sound during operation: This is normal and is caused by refrigerant gas flowing through both indoor and outdoor units.
---|---
Low hissing sound when the system starts, has just stopped running, or is defrosting: This noise is normal and is caused by the refrigerant gas stopping or changing direction.
Squeaking sound: Normal expansion and contraction of plastic and metal parts caused by temperature changes during operation can cause squeaking noises.
The outdoor unit makes noises| The unit will make different sounds based on its current operating mode.
Dust is emitted from either the indoor or outdoor unit| The unit may accumulate dust during extended periods of non- use, which will be emitted when the unit is turned on. This can be mitigated by covering the unit during long periods of inactivity.
The unit emits a bad odor| The unit may absorb odors from the environment (such as furniture, cooking, cigarettes, etc.) which will be emitted during operations.
The unit’s filters have become moldy and should be cleaned.
The fan of the outdoor unit does not operate| During operation, the fan speed is controlled to optimize product operation.
Operation is erratic, unpredictable, or unit is unresponsive| Interference from cell phone towers and remote boosters may cause the unit to malfunction. In this case, try the following:

•  Disconnect the power, then reconnect.

•  Press ON/OFF button on remote control to restart operation.

NOTE
If problem persists, contact a local dealer or your nearest customer service center. Provide them with a detailed description of the unit malfunction as well as your model number.

TROUBLESHOOTING

When troubles occur, please check the following points before contacting a repair company.

PROBLEM POSSIBLE CAUSES SOLUTION
Poor Cooling Performance Temperature setting may be higher than
ambient room temperature Lower the temperature setting
The heat exchanger on the indoor or outdoor unit is dirty Clean the affected

heat exchanger
The air filter is dirty| Remove the filter and clean it according to instructions
The air inlet or outlet of either unit is blocked| Turn the unit off, remove the obstruction and turn it back on
Doors and windows are open| Make sure that all doors and windows are closed while operating the unit
Excessive heat is generated by sunlight| Close windows and curtains during periods of high heat or bright sunshine
Low refrigerant due to leak or long- term use| Check for leaks, re-seal if necessary and top off refrigerant
Excessive heat is generated by sunlight| Excessive heat is generated by sunlight
Too many sources of heat in the room (people, computers, electronics, etc.)| Reduce amount of heat sources
Poor Heating Performance| The outdoor temperature is extremely low| This model is designed to work down to

-13°F, however, heating performance is impacted at temperatures below freezing

Cold air is entering through doors and windows| Make sure that all doors and windows are closed during use
Low refrigerant due to leak or long-term use| Check for leaks, re-seal if necessary, and top off refrigerant
The unit starts and stops fre- quently| There’s too much or too little refrigerant in the system| Check for leaks and recharge the system with refrigerant
Incompressible gas or moisture has entered the system| Evacuate and recharge the system with refrigerant
The compressor is broken| Replace the compressor
The voltage is too high or too low| Install a manostat to regulate the voltage
The unit is not working| Power failure| Wait for the power to be restored
---|---|---
The power is turned off| Turn on the power
The fuse is burned out| Replace the fuse
Remote control batteries are dead| Replace batteries
The Unit’s 3-minute protection has been activated| Wait three minutes after restarting the unit
Timer is activated| Turn timer off
Indicator lamps continue flashing or error code appears| The unit may stop operation or continue to run safely. If the indicator lamps continue to flash or error codes appear, wait for about 10 minutes. The problem may resolve itself.

If not, disconnect the power, then connect it again. Turn the unit on.

If the problem persists, disconnect the power and contact your nearest customer service center.

NOTE
If your problem persists after performing the checks and diagnostics above, turn off your unit immediately and contact an authorized service center.

WIRING DIAGRAM

DRAS12F1B

DURASTAR-DRAS12F1B-Floor-Mounted-Indoor-Unit-Split-Style-Air-Conditioner-
FIG- \(17\) DURASTAR-DRAS12F1B-Floor-Mounted-Indoor-Unit-Split-Style-Air-Conditioner-
FIG- \(18\)

(INDOOR UNIT)

CODE PART NAME
CN1-CN20 P.C BOARD SOCKETS
FAN INDOOR DC FAN MOTOR
M1 UPPER OUTLET SWING MOTOR
M2 LOWER OUTLET SWING MOTOR
RT1 ROOM TEMPERATURE
RT2 PIPE TEMPERATURE
XP1-XP5 CONNECTORS
XS1-XS5 CONNECTORS
XT1 TERMINAL
J1 JUMPER

NOTICE1:
THE TYPE_SELECTION AND MO/MU HAS BEEN SET BEFORE LEAVING THE FACTORY,ANYONE CAN’T MODIFY IT EXCEPT THE MAINTENANCE PERSON.
NOTICE2:
IF THE NET MODULE IS INSTALLED, PLEASE MAKE SURE THE J1 IS REMOVED.

Dotted line indicates the element is optional,the actual shape shall prevail.

ERROR CODES – INDOOR UNIT

DURASTAR-DRAS12F1B-Floor-Mounted-Indoor-Unit-Split-Style-Air-Conditioner-
FIG- \(20\)

DURASTAR.COM