DURATECH DFI-150 Flow Inverter User Manual
- June 3, 2024
- DURATECH
Table of Contents
Manual
DFI-150 FLOW DFI-150
Box content
Included in the final package with the DFI-150 are:
- 1x DFI-150 water circulation pump (incl. 3,5m power cable)
- 1x Inlet and outlet Fitting Ø63mm
- 1x Quick Guide
About the DFI-150
The Dura Flow inverter circulation pump, DFI-150 is a self-priming centrifugal
pump for recirculation and filtration of the water in small and medium sized
pools with prefilter integrated.
The DFI-150 is part of the full DuraLink solution. Communication is done using
power line communication. Which means that only 1 cable connection is required
for power and communication between a remote-control system and the
circulation pump.
The inverter for the DFI-150 is integrated in the circulation pump and allows
the pump to run run at variable speeds.
The pump is using a permanent magnet electro motor which is energy efficient.
The DFI-150 is durable, reliable and easy to install.
The ambient temperature must be between 0 °C and + 40 °C and must be as
constant as possible. The relative humidity at the installation location must
not exceed 90%, no condensation may occur. Keep out of direct sun light and
away from heat sources.
The DFI-150 will only be controllable by the LINK Master.
Technical specifications
3.1. General specifications
- Input Voltage: 230VAC 50Hz 16A
- Flow rate max: 28,8m3/h
- Max. head: 22m
- Max current: 8,2A
- Min. speed: 750RPM
- Max. speed: 3450RPM
- P1 (Input power): 1,7kW (power consumption)
- P2 (Output power): 1,1kW/1.5HP (rated power)
- Ambient Air Temperature: 0°C to +40°C
- Humidity: 10% to 90% RH – non condensing
- Ingress protection rate: IP55
- Box outer size: 690 x 280 x 410 mm
- Weight: 23 kg
- CE compliance
3.2. DFI-150 overview
3.2.1 Spare parts list
Diagram reference number | Description | Spare part number |
---|---|---|
4 | Filter-basket | SP_DFI-001 |
1, 2, 3 | The filter cover + sealing | SP_DFI-002 |
3 | Filter cover sealing | SP_DFI-003 |
13 | Mechanical sealing | SP_DFI-004 |
5, 6, 7 | 63 mm fitting (pipe fitting + nut fitting) with sealing | SP_DFI-005 |
12 | Impeller | SP_DFI-006 |
8, 9 | drain plug with o-ring | SP_DFI-007 |
15 | Electrical inverter board assembly (incl. housing) | SP_DFI-008 |
11 | support block | SP_DFI-009 |
10 | diffusor o-ring | SP_DFI-010 |
14 | pump cover o-ring | SP_DFI-011 |
3.3. Wiring diagram and terminal blocks
See LINK Master manual for further details regarding the wiring diagram and
terminal blocks for connecting the power cable.
Installation instructions
4.1. Warnings
Before installation and use of the pump, the basic safety warnings need to be
understood. Specific contents include the following warnings:
- Be careful of electric shock. The pump can only be installed in combination with the LINK Master. The LINK Master has all safety devices on board to make for a safe installation. Please check the LINK Master manual for instructions on how to install and connect the DFI-150 correctly with the LINK Master. The DFI-150 has a pre-connected in power cable with a length of 3,5 m.
- Make sure the pump motor is disconnected from the main power supply in case of maintenance or repair of the DFI-150.
- The national standards and regulations for installation of the country in which the pump is installed, should be followed.
- Failure to comply with safety instructions may result in serious body injury or death. The installation and maintenance of the pump must be done by professional pool service personnel, installers or operators.
- The owner of the pool must carefully read the safety warnings and instructions before using the pump.
Operation modes
For operation of the pump and instructions for scheduling, please consult the manual of the Link Master (DLM-450, DLM-600).
Special function description and application
6.1. Internal protection functions
See addendum 8.1 for corresponding error codes. In case of error, the error
code will be displayed on the LinkTouch or can also be retrieved in the
DuraCloud application.
6.1.1. Overvoltage and undervoltage protection
- If the AC voltage is higher than 240V or lower than 208V.
- Starting the motor is disabled.
- The following codes can be displayed: OV1 for overvoltage and UV1 undervoltage.
6.1.2. Over-current protection
- After the fault occurs, the controller stops the output and automatically clears the fault and restarts after 10 or 30 seconds.
- After 3 consecutive errors, the motor will not restart and one of the following error codes will be displayed: OC1, OC2, OC3, OC4.
6.1.3 IPM (Intelligent Power Module) protection
- In case of IPM failure, the motor will immediately stop running
- The following error code will be displayed: OC3.
- The controller will automatically clear the fault and will restart the pump after 30 seconds.
- After 3 consecutive errors, the motor will not restart, and the fault can’t be cleared. Only after a power cycle of the motor, the fault will be cleared.
- In case the OC3 alarm remains even after a power cycle, then this means that the internal hardware has failed.
6.1.4. Overheat protection
- When the motor temperature is higher than 95 °C, the system will automatically and gradually reduce the motor speed in steps of 50RPM to protect the motor.
- When the temperature is too high, the system stops running. The following error code will be shown: OH1.
6.1.5. Dry pumping protection (no water protection)
- The dry pumping protection is controller by the LINK Master
- This feature only works from and above 2100 RPMs
Attention points
7.1. High-speed running at start-up
Every time the pump will be activated, the motor will start running at high
speed to remove the air in the pipe. This is controlled by the LINK Master.
7.2. Filter cleaning
The filter basket must be cleaned on a regular basis to guarantee the
waterflow and to avoid any damage of the pump due to a blocked filter.
Addendum
8.1 Error codes
Display
Code| Fault Name| Failure Cause| Description
---|---|---|---
OC I| Overcurrent during
drive speed change| – Overloaded
– Use of a special motor or a motor with a power greater than the applicable
power
– The output side of the driver has a fault short circuit and grounding| At
this time:
1)Please check whether the motor and the driver match
2)Please check whether the output terminal of the driver is short circuited or
connected to the wrong wire
3)Please reduce the load
0C2| Overcurrent in the drive at steady speed| – Overloaded
– Use of a special motor or a motor with a power greater than the applicable
power
– The output side of the driver has a fault short circuit and grounding| At
this time:
1)Please check whether the motor and the driver match
2)Please check whether the output terminal of the driver is short circuited or
connected to the wrong wire
3)Please reduce the load
0C3| Drive instantane- ous overcurrent or overheating| – Overloaded
– The output side of the driver has a fault short circuit and grounding
-Drive IPM module is damaged| At this time:
1)Please check whether the wiring on the
output side of the drive is normal and
whether there is a short circuit
2)Try to reduce the load
3)Please check that the drive is overheated. and try again if the drive cods
down
41 If the above situation still keeps reporting OC 3 failure. please retum to
the factory for repair
0C4| Overcurrent of driver module| Overcurrent of driver module| – The system
will restart 30s after the fault
– After 3 consecutive occurrences. the pump won’t restart
OVI| Main Circuit Over- voltage| – Input power voltage is too high
– The power supply voltage exceeds the working range of the drive when
powering on| At this time:
I) Please check whether the power supply voltage is consistent with the
working voltage of the drive
2)Please check whether the power on device is in good contact to avoid instant
overvoltage caused by poor power on contact
3)For other questions. please return to the factory for repair and indicate
the situation
0-1| Heat sink is over- heated| – The ambient temperature is too high – There
are hot objects around
– The cooling fan of the drive stops working
– Blocked radiator| At this time:
1)Please check the ambient temperature and move the drive to a cool and
ventilated place to avoid outdoor high temperature exposure
2)Please check if there is a heating element around. please remove if there is
3)Please check if the coding fan is blocked or broken
SVI| Low voltage of main circuit| – Instantaneous power failure occurred – The
input power voltage fluctuates – The wiring of the input power supply is loose
– Phase loss of input power
– Cut off the power. the drive is dischar-| At this time:
1)Please check if the input power supply voltage is stable
2)Please check whether the wiring of the input power supply is loose or
3)Please e check whether the input power supply lacks phase
1E| Current transformer self-check failure| Drive internal failure| At this
time:
I) Please check if there is a strong electronic interference source near the
dnve and remove it
2) If the CE failure continues to be reported. please return to the factory
for repair
References