DURATECH PL-REM-60 LINK Driver Instruction Manual
- October 27, 2023
- DURATECH
Table of Contents
PL-REM-60 LINK Driver
Instruction Manual 12-09-22
LINK Driver
Technical specifications
Electrical specifications
Nominal Input voltage | 230 VAC 50 Hz |
---|---|
Output voltage on Lamp Output | 12 VAC |
Max output current on Lamp Output | 5A |
Transformer VA rating | 60VA |
Frequency band transmitter | 868 MHz |
IEC Protection Class | Class II ![Icon](https://manuals.plus/wp- |
content/uploads/2022/05/Screenshot_3-305.png)
General specifications Controller
Ambient air temperature | 0°C … +40°C |
---|---|
Humidity | 10% … 90% RH |
non condensing
Dimensions| 150x157x51 mm
Weight| 1,3 kg
Ingress Protection Rate| IP54
Box contents
- PL-REM-60 controller
- Handheld transmitter
- Spare battery
- Screws (4x) & wall plugs (4x)
- Owner’s Manual
Installation instructions
- Connect a 230VAC power source to the “220-240VAC INPUT” terminal.
- Connect the swimming pool lights to the “Lamp 12VAC output” terminal
Make sure the total load of pool lights does not exceed 60Watt
Pairing handheld transmitter & controller
The handheld transmitter is already paired in the factory and ready to use.
The PL-REM-60 can pair with up to 6 handheld transmitters. In case a problem
arises, the pairing process can be done manually:
Manual Pairing process:
Make sure the PL-REM-60 is connected to a power source.
-
Press the pairing button on the small circuit board, inside the controller for at least 5 seconds.
–> The LED will start to blink fast -
Within 25 seconds, press any button on the handheld transmitter.
–> If the transmitter is paired correctly, the LED will flash slowly for 5 times
–> If the PL-REM-60 pairing memory is full, the LED will flash 15 times.
This means 6 handheld devices have already been paired.
To unpair all handheld transmitters with the controller: Push the pairing
button for at least 5 seconds, then do nothing for at least 25 seconds.
–> The pair memory will be erased – the green LED will flash 5x on/off.
If no transmitters are paired, the PL-REM-200 will accept messages from any transmitter!
Handheld transmitter functions
Replacing transmitter battery
- Remove the philips head screw and open the transmitter
- Replace the battery, respecting the polarity
Battery type: A23 12V
Troubleshooting
PROBLEM | SOLUTION |
---|---|
The controller doesn’t react to transmitter commands | • Check the battery of |
the hand- held transmitter
• The transmitter is not paired correctly with the controller.
Repeat the pairing process
• Reduce the distance between handheld transmitter and PLREM-60 and/or
eliminate obstacles
The pool lights don’t work| • Check the red status LED
• Check if there is 12VAC output at the terminals of the controller
Declaraction of Conformity
Declarations of conformity covering this product are available for download
from the House of Eurotech website: www.duratech.be
Contact details
Propulsion Systems bv
Doormen 72
1785 Merchet, Belgium
Tel +32 2 461 02 53
www.duratech.be
info@propulsionsystems.behttp://www.propulsionsystems.be
DURALIK
402-0081-2
We reserve the rights to change all or part of the contents of this document without prior notice
Documents / Resources
|
DURATECH PL-REM-60 LINK
Driver
[pdf] Instruction Manual
PL-REM-60, LINK Driver, PL-REM-60 LINK Driver, Driver
---|---
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>