DURATECH PL-REM Controller User Manual

October 27, 2023
DURATECH

DURATECH Logo Manual
PL-REMDURATECH PL REM Controller LINK Driver

Technical specifications

Electrical specifications

Nominal Input voltage
Max rating Relay Contacts
“Color Light”, “A” and “B”
Resistive Load
Inductive Load
Frequency band transmitter
IEC Protection Class| 230 VAC  50 Hz
14A  250VAC
14A  30VDC
6A  250VAC
6A  30VDC
868 MHz
Class II ****
---|---

General specifications Controller

Ambient air temperature
Humidity
Dimensions
Weight
Ingress protection rate| 0°C … +40°C
10% … 90% RH
non condensing
150x157x51 mm
500 g
IP54
---|---

**** For operation only with 12VAC safety isolation transformer to power Spectravision ® LED Pool Lights

Box contents

  1. PL-REM controller
  2. Handheld transmitter (Dural ink™ version)
  3. Spare battery (type A23 12V)
  4. Screws (4x) & wall plugs (4x)
  5. Owner’s manual

DURATECH PL REM Controller - Box contents

Installation instructions

Option 1: PL-REM in transformer primary

  • Connect a 230VAC power source to the “220-240VAC INPUT” terminal
  • Connect the primary circuit of a 12VAC transformer (sold separately) in series with the “Color Light” terminal of the PL-REM.

Optional: The “Switch A” & “switch B” terminals can be used to control auxiliary circuits like a pool cover or garden lights.
**** The “Color Light” relay contact has an output of 14A, which can drive a 12V transformer of max. 3000W (220Vx14A).DURATECH PL REM Controller - Box
contents 2

Option 2: PL-REM in transformer secondary

  • Connect a 230VAC power source to the “220-240VAC INPUT” terminal
  • Connect the secondary circuit of a 12VAC transformer (sold separately) in series with the “Color Light” terminal of the PL-REM.

Optional: The “Switch A” & “switch B” terminals can be used to control auxiliary circuits like a pool cover or garden lights.
**** The “Color Light” relay contact has an output of 14A, or 170W on a 12V transformer secondary (14Ax12V). The total load of pool lights can not exceed this.DURATECH PL REM Controller - Box contents 1

Pairing handheld transmitter & controller

The handheld transmitter is already paired in the factory and ready to use. The PL-REM can pair with up to 6 handheld transmitters. In case a problem arises, the pairing process can be done manually:
Manual Pairing process:
Make sure the PL-REM is connected to a power source.

  1. Press the pairing button on the small circuit board, inside the controller for at least 5 seconds. –> The LED will start to blink fast
  2. Within 25 seconds, press any button on the handheld transmitter.
    –> If the transmitter is paired correctly, the LED will flash slowly for 5 times
    –> If the PL-REM pairing memory is full, the LED will flash 15 times.
    This means 6 handheld devices have already been paired.

To unpair all handheld transmitters with the controller: Push the pairing button for at least 5 seconds, then do nothing for at least 25 seconds.
–> The pair memory will be erased – the green LED will flash 5x on/off.
**** If no transmitters are paired, the PL-REM-200 will accept messages from any transmitter!DURATECH PL REM Controller - Box contents
3

Handheld transmitter functions

DURATECH PL REM Controller - Handheld transmitter
functions

Replacing transmitter battery

  • Remove the philips head screw and open the transmitter
  • Replace the battery, respecting the polarity
    Battery type: A23 12V

DURATECH PL REM Controller - Handheld transmitter functions
1

Change Relay A/B mode

The relays A & B can be used to control auxiliary circuits like garden lighting or a pool cover.
The operation mode of these relays can be modified:
Option 1: Normal open/closed contact
Option 2: Pulsed contact
Modification process:

  1. Locate the 5 pinholes on the circuit board
  2. Make a connection between pin 1 and 2 (use a piece of wire, or a paperclip)
  3. Power ON the device by connecting a 230VAC power source to the 220-240VAC INPUT terminal
  4. Power OFF the device
  5. Remove the connection between pin 1 and 2 Every time the above process is repeated, the A & B relays switch between Normal open/closed mode and Pulsed operation mode
    DURATECH PL REM Controller - Handheld transmitter functions
2

Troubleshooting

PROBLEM SOLUTION
The controller doesn’t react to transmitter commands •Check the battery of

the handheld transmitter
•The transmitter is not paired correctly with the controller.
Repeat the pairing process
•Reduce the distance between handheld transmitter and PLREM and/or remove obstacles
The pool lights don’t work| •Check if all connections are made according to the electrical scheme on page 5 or 6.
•Check if the “Color Light” output terminals of the controller  switch on and of when pushing  the on/off button on the transmitter.

Declarations of Conformity

Declarations of conformity covering this product are available for download from the House of Eurotech website: www.duratech.be DURATECH PL REM Controller - Handheld transmitter
functions 3

Contact details

Propulsion Systems bv
Doormen 72
1785 Merchets, Belgium
Tel +32 2 461 02 53
www.duratech.be
[email protected]

http://www.propulsionsystems.be
DURA LINK
We reserve the rights to change all or part of the contents of this document without prior notice
402-0248-2

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

DURATECH User Manuals

Related Manuals