HEINNER HTFA-M20WH Tower Fan Heater Owner’s Manual

August 23, 2024
HEINNER

HEINNER-Logo

HEINNER HTFA-M20WH Tower Fan Heater

HEINNER-HTFA-M20WH-Tower-Fan-Heater-Product

Specifications:

  • Product: Tower Fan/Heater
  • Model: HTFA-M20WH

Product Information

  1. Introduction
    Please read the instructions carefully and keep the manual for future reference. This manual guides the installation, usage, and maintenance of the unit to ensure correct and safe operation.

  2. Content of Your Package

    • Tower fan/Radiator
    • Remote control
    • User manual
    • Certificate of warranty
    • Declaration of conformity
  3. Safety Instruction
    General Warnings:

  4. Some parts can become hot, so take caution around children and vulnerable individuals.

  5. Replace damaged cords by a qualified person to avoid hazards.

  6. Avoid placing the heater below a socket outlet.

  7. Do not cover the heater to prevent overheating.

  8. Product Description
    The product features a control panel, air outlet, and fan/heater switch base for easy operation.

  9. Using the Appliance
    The control panel includes various functions like mode selection, timer settings, fan speed adjustment, and more. The display panel provides information on different modes and features. The appliance also includes safety features like tip-over protection, cool-down feature, overheat protection, and light indication for operational awareness.

  10. Remote Control
    The remote control allows for convenient operation, including startup/shutdown of oscillation, speed/time adjustments, mode switching, and timer settings. Use AAA batteries for the remote control.

Battery Installation for Remote Control

Note:
Batteries are not included in the packaging. Follow the instructions to install batteries for the remote control.

FAQ:

Q: What should I do if the heater overheats?
A: If the heater overheats, turn it off, unplug it, remove any obstructions, allow it to cool, and then resume operation.

Features

  • 2 in 1: Fan and Heater
  • Digital control
  • LED Display

INTRODUCTION

Please read the instructions carefully and keep the manual for future information. This manual is designed to give all necessary instructions concerning installation, use and maintenance of the unit. In order to operate the unit correctly and safely, please read this instruction manual carefully before installation and use.

CONTENT OF YOUR PACKAGE

  • Tower fan/Radiator
  • Remote control
  • User manual
  • Certificate of warranty
  • Declaration of conformity

SAFETY INSTRUCTION

GENERAL
Read all instructions carefully and keep this manual for future reference.

  1. This appliance can be used by children aged 8 years and above and persons with reduced physical, sensory, or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning the use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be done by children without supervision.
  2. Children of less than 3 years should be kept away unless continuously supervised. Children aged from 3 years and less than 8 years shall only switch on/off the appliance if it has been placed or installed in its intended normal operating position and they have been given supervision or instruction concerning the use of the appliance in a safe way and understand the hazards involved.
  3. Children of less than 3 years should be kept away unless continuously supervised.
  4. Never insert fingers, pencils, or any other object through the grille when the fan is running.
  5. Disconnect the fan when moving from one location to another.
  6. Be sure the fan is on a stable surface when operating to avoid overturning.
  7. DO NOT use the fan in the window, rain may create electrical hazards.
  8. Indoor and household use only.

WARNINGS

  1. Some parts of this product can become very hot and cause burns. Particular attention must be given to where children and vulnerable people are present.
  2. If the supply cord is damaged, it must be replaced by the manufacturer its service agent, or a similarly qualified person to avoid a hazard.
  3. The heater must not be located immediately below a socket outlet.
  4. To avoid overheating, do not cover the heater.
  5. Do not use the heater in the immediate surroundings of a bath, a shower, or a swimming pool.
  6. Do not use the heater if it has been dropped.
  7. Do not use the heater if there are visible signs of damage to the heater.
  8. Use the heater on a horizontal and stable surface, as applicable.
  9. Do not use the heater in small rooms when they are occupied by persons not capable of leaving the room on their own unless constant supervision is provided.
  10. To reduce the risk of fire, keep textiles, curtains, or any other flammable material at a minimum distance of 1 m from the air outlet.
  11. To protect against the risk of electrical shock, do not immerse the unit, cord, or plug in water or other liquid.
  12. When the appliance is not in use and before cleaning, unplug the appliance from the outlet.
  13. When the product is assembled, the rotor blade guard shall not be taken off anymore.
  14. Ensure that the product is switched off from the supply mains before removing the guard.

PRODUCT DESCRIPTION

HEINNER-HTFA-M20WH-Tower-Fan-Heater-Fig-1

USING THE APPLIANCE

  1. Before using the appliance check if the power wire is in good condition.
  2. The product adopts a 220V AC power supply. Before use, please confirm if the rated current of the power socket meets the local requirements with a safe grounding device, otherwise, please replace it with the qualified socket.
  3. Plug in the power cord, power on the indicator lights up, there will be a long beep, and the product will convert to standby mode.
  4. To use the device in heater mode, make sure the slider switch is fully engaged to the heater side (right). Press the mode button to start the heater mode, and press the mode button again to switch between the different heat levels.

NOTE

  • If you move the slider switch while the device is in operation, you will need to press the mode button to enable the heater.
  • To use the device in fan mode, make sure the slider switch is fully engaged to the fan side (left). Press the mode button to switch between the different fan speed levels.
Control Panel

HEINNER-HTFA-M20WH-Tower-Fan-Heater-Fig-3HEINNER-HTFA-M20WH-Tower-Fan-Heater-Fig-4

Display Panel

HEINNER-HTFA-M20WH-Tower-Fan-Heater-Fig-5 HEINNER-HTFA-M20WH-Tower-Fan-Heater-Fig-6

NOTE

  1. The display will be turned off automatically after 60 seconds.
  2. When the device is tipped over, it will activate the safety tip-over protection. The display will show a P4 error code. Lift the device back onto its base, and it will return to its normal state.
  3. When the heater is turned off, the fan will continue to run for 15 seconds to dissipate the heat as a cool-down feature.

Light Indication
This fan heater is equipped with a light indicator that illuminates whenever the heater is plugged in and turned on. It will continue to glow even if the thermostat has cycled the heating elements off. This feature is to prevent you from being unaware that the heater is operating and maintaining the temperature of the room. When you do not wish the heater to control the room temperature, turn off the heater and remove the plug from the electrical outlet.

Overheat Protection
This heater is equipped with a temperature control component for overheat protection that will be activated when the internal temperature exceeds normal operating temperatures. If this occurs, turn the heater “OFF,” unplug it, inspect, and remove any objects on or adjacent to the heater. Allow it to cool for a few minutes, and then plug it back in and resume normal operation.

REMOTE CONTROL
  • The remote control should be normally used within 5 meters of the front of the product and 30 degrees of the deviation angle.
  • The battery contains many heavy metals, acids bases, etc., which may threaten human health. Waste batteries should be recycled separately.

HEINNER-HTFA-M20WH-Tower-Fan-Heater-Fig-7

Battery for remote control.

  • Use manganese or alkaline batteries of type “AAA”.
  • Do not use rechargeable batteries.

BATTERY INSTALATION FOR REMOTE CONTROL

NOTE: Battery not included in the packaging.

  1. Slide the battery compartment cover.
  2. Insert the batteries, and make sure that the batteries are placed as shown in Fig 2.
  3. Slide back the battery cover

BATTERY WARNINGS

  1. Do not dispose of batteries in the fire; batteries may explode or leak.
  2. Do not mix old and new batteries.
  3. Do not mix alkaline, standard (carbon-zinc) or rechargeable (nickel-cadmium) batteries.
  4. Non-rechargeable batteries are not to be recharged.
  5. Batteries are to be inserted with the correct polarity.
  6. Exhausted batteries are to be removed from the product.
  7. The batteries must be removed from the remote controller before it is scrapped and disposed of safely.

CLEANING AND MAINTENANCE

The fan requires minimal maintenance. Do not try to fix it by yourself. Refer to qualified service personnel if service is needed.

  1. Before cleaning and assembling, always turn the power switch off and unplug the appliance.
  2. Turn the appliance “OFF”, unplug it, and wait for the heater to cool down.
  3. To ensure adequate air circulation to the motor, keep vents at the rear of the motor free of dust. Do not disassemble the appliance to remove dust.
  4. Please wipe the exterior parts with a soft cloth soaking in a mild detergent.
  5. Do not use any abrasive detergent or solvents to avoid scratching the surface.
  6. Do not use any of the following as a cleaner: gasoline, thinner.
  7. Do not allow water or any other liquid to enter the motor housing or interior parts.
  8. Be sure to unplug from the electrical supply source before cleaning.
  9. Plastic parts should be cleaned with a soft cloth moistened with mild soap thoroughly remove soapsuds with a dry cloth.

WARNING
This heater cannot achieve accurate temperature control of the environment, and thus cannot be used to warm the storage places with various items, plants, and special places for animals.

TROUBLESHOOTING

Operation of your appliance can lead to errors and malfunctions. The following tables contain possible causes and notes for resolving an error message or malfunction. It is recommended to read the table below carefully to save the time and money that may cost for calling to the service center.

Problem

| Cause|

Solution

---|---|---
The remote does not work| ●  The battery needs replacing.| Replace the battery.
●  The remote is being used more than 5m away from the fan.| Use the remote closer to the fan and make sure it is pointing directly at the display panel.
After the power is engaged, the power indicator light does not illuminate, and the appliance does not work.| ●  The plug may not be in plugged in well.| Check whether the plug is properly inserted into the receptacle.
●  The slider switch is not fully engaged on the left or right side| Check whether the slider switch is fully engaged to the left (fan) or right (heater).

CUSTOMER CARE AND SERVICE

  • Always use original spare parts.
  • When contacting our Authorised Service Centre, ensure that you have the following data available: Model and Serial Number.
  • The information can be found on the rating plate. Subject to change without notice.

TECHNICAL DATA

Voltage 220-240V~50Hz
Total Power 2000 W
Fan Power 45 W
Item Symbol
--- ---

Heat output

| Type of heat input, for electric local space heaters only (select one)
Nominal heat output|

Pnom

| 2,2| kW| Manual heat charge control with integrated thermostat| [no]
Minimum heat output (indicative)|

Pmin

|

N/A

|

kW

| Manual heat charge control with room and/or outdoor temperature feedback| [no]
Maximum continuous heat

output

|

Pmax,c

|

2,2

|

kW

| Electronic heat charge control with room and/or outdoor temperature feedback|   [no]
Auxiliary electricity consumption| Fan-assisted heat output| [no]
At nominal heat

output

| elmax| N/A| kW| Type of heat output/room temperature control (select one)
At minimum heat output| elmin| N/A| kW| Single-stage heat output and no room temperature control| [no]
In standby mode| elSB| 0,46|

kW

| Two or more manual stages, no room temperature

control

|   [no]
 |  |  |  | With mechanic thermostat room temperature control| [yes]
 |  |  |  | With electronic room temperature control| [no]
 |  |  |  | Electronic room temperature control plus day timer| [no]
 |  |  |  | Electronic room temperature control plus week timer| [no]
 |  |  |  | Other control options (multiple selections possible)
 |  |  |  | Room temperature control, with presence detection| [no]
 |  |  |  | Room temperature control, with open window detection| [no]
 |  |  |  | With distance control option| [no]
 |  |  |  | With adaptive start control| [no]
 |  |  |  | With working time limitation| [no]
 |  |  |  | With a black bulb sensor| [no]
Remark:

For electric local space heaters, the measured seasonal space heating energy efficiency cannot be lower than the declared value at the nominal heat output of the unit.

Thank you for purchasing this product. If you need support with your product, visit our website using the links below.

Environment-friendly disposal

You can help protect the environment!
Please remember to respect the local regulations: hand in the non-working electrical equipment to an appropriate waste disposal center.

HEINNER is a registered trademark of Network One Distribution SRL. Other brands and product names are trademarks or registered trademarks of their respective holders. No part of the specifications may be reproduced in any form or by any means or used to make any derivative such as translation, transformation, or adaptation without permission from NETWORK ONE DISTRIBUTION.

This product conforms to the norms and standards of the European Community.

Importer: Network One Distribution

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals