Product Usage Instructions

To prepare and set up the air conditioner, follow the steps outlined in the user manual section 6.

  • Set the operating mode as described in section 7.2.
  • Activate the sleep mode for quieter operation (section 7.3).
  • Use the swing mode to distribute air evenly (section 7.4).
  • Set a timer for automatic operation (section 7.5).
  • Learn about the safety functions of the air conditioner in section 8 to ensure safe usage.
  • Connect the air conditioner to the designated app by following the instructions in section 9.
  • Clean the air conditioner regularly following the guidelines provided in section 11.

FAQ

  • Q: How do I install the condensate drain hose?
  • A: Refer to section 6.1 in the user manual for detailed instructions on installing the condensate drain hose.
  • Q: Can I control the air conditioner using a mobile app?
  • A: Yes, you can control the air conditioner using the designated mobile app. Refer to section 9 for setup instructions.
  • Q: What should I do in case of a malfunction?
  • A: Section 10 of the user manual guides troubleshooting common issues with the air conditioner.

Information about this user manual

  • Thank you for choosing our product. We hope you enjoy using this appliance.
  • Please read the safety instructions and the user manual carefully before using the appliance for the first time. Note the warnings on the appliance and in the user manual.
  • Always keep the user manual close to hand. If you sell the appliance or give it away, please ensure that you also pass on this user manual. It is an essential component of the product.

Explanation of symbols
If a block of text is marked with one of the warning symbols listed below, the hazard described in that text must be avoided to prevent the potential consequences described there from occurring.

MD-37735-Smart-Medion-Life-P502-FIG-1 MD-37735
-Smart-Medion-Life-P502-FIG-2

Proper use

This appliance is used for cooling the air in enclosed indoor spaces.
The appliance is only intended for private use and not for industrial/commercial use.
Please note that we shall not be liable in cases of improper use:

  • Do not modify the appliance without our prior consent. Use only auxiliary appliances approved or supplied by us.
  • Only use replacement parts or accessories that we have supplied or approved.
  • Comply with all the information in this user manual, especially the safety instructions. Any other use is considered improper and can cause personal injury or property damage.

Safety instructions

  • Keep the appliance and its accessories out of the reach of children.
  • This appliance can be used by children of 8 years and older, and by people with reduced physical, sensory or mental capacity, or with a lack of experience and/or knowledge, but only with proper supervision, or if they have been told how to use the appliance safely, and have understood the risks involved if they use it improperly.
  • Children must not be allowed to play with the appliance.
  • Cleaning and user maintenance must not be carried out by children.
  • Children do not recognize the dangers that can arise when handling electrical appliances. Please be particularly careful while using the appliance if there are children nearby.
  • Children younger than 8 must be kept away from the appliance and the mains cable.

Power supply
WARNING!
Risk of electric shock/short circuit!
There is a risk of electric shock/short circuit from live parts.

  • Do not immerse the appliance in water or other liquids or hold it under running water because this could cause an  electric shock.

  • Only connect the appliance to a properly installed and easily accessible socket that is close to where you are using the appliance. The local mains voltage must correspond to the technical specifications for the appliance.

  • Unplug the appliance’s mains plug from the power socket:

    • when you are cleaning the appliance
    • if you are no longer using the appliance
    • if the appliance is left unattended
    • during thunderstorms.
  • Always hold the plug to pull it out and never pull the mains cable.

  • Do not place the appliance near to sinks and do not expose it to water droplets or spray.

  • Use the appliance indoors only.

  • Do not allow the mains cable to come into contact with hot objects or surfaces.

  • Do not use if the appliance if the appliance or the mains cable is visibly damaged or if the appliance has been dropped.

  • Check the appliance and the mains cable for damage before using the appliance for the first time, and after each use.

  • Completely unwind the mains cable.

  • Do not kink or crush the mains cable.

  • Contact our Service team without delay if the appliance has been damaged during transport.

  • Under no circumstances should you make any changes to the appliance yourself. Do not attempt to open and/or repair a part of the appliance yourself.

  • The mains cable must exclusively be repaired by a professional workshop or contact the Service Centre in order to avoid any hazards.

  • Never touch the plug with damp or wet hands.

  • Do not expose the appliance to extreme conditions. Avoid:

    • high humidity or wet conditions
    • extremely high or low temperatures
    • direct sunlight
    • naked flames
    • mechanical vibrations or shocks
    • excessive dust
    • lack of ventilation, e.g. in a cupboard or bookshelf.
  • Make sure that the appliance is switched off before plugging in the mains plug.

  • Never unplug the mains plug from the socket while the appliance is running.

  • Do not use multi-plugs.

  • Immediately turn off the appliance and remove the mains plug if you notice an unpleasant smell (smell of burning).

  • Do not use flammable cleaning agents.
    Do not use agents other than those recommended by the manufacturer to speed up the thawing process or for cleaning.

  • Ensure the mains cable does not become a tripping hazard –do not use an extension cable.

  • Place the appliance in an upright position on a stable, level surface.

  • Place the appliance only on the floor.

  • Do not operate the appliance without the filter strainers in place.

Information on refrigerant
The refrigerant R290 used in this appliance does not have any harmful effect on the ozone layer (ODP), a negligible greenhouse effect (GWP) and is available worldwide. Due to its energy-efficient properties, R290 is ideally suited as a refrigerant for this application. Due to the high flammability of the refrigerant, special precautions must be taken.

WARNING!
Risk of fire!
The refrigeration system of the appliance contains the natural refrigerant propane (R290).

  • Do not damage the refrigerant circuit.
  • During operation, storage and installation, the room should have an area of at least 4 m² in order to ensure an adequate amount of air in case of damage to the refrigeration system.
  • If the refrigeration system has nevertheless become damaged, ventilate the room. Evacuate the room. Avoid naked flames and ignition sources. Have the appliance repaired by a qualified technician before using it again.
  • Tampering with the refrigerant circuit is prohibited and invalidates the warranty.
  • Do not use agents other than those recommended by the manufacturer to speed up the thawing process or for cleaning.
  • Extremely flammable gas: Avoid naked flames, sparks and ignition sources when using, maintaining and disposing of the appliance.
  • Contains pressurized gas; can explode when heated.
  • In the event of a fire, do not extinguish any leaking gas until the leak can be safely eliminated.
  • During repair and maintenance work (or when working with heat on the appliance): Have a powder or CO2 fire extinguisher nearby for emergencies.
  • Store the appliance in a well-ventilated place away from sunlight.
  • Do not remove safety signs, stickers or labels from the appliance and ensure they are legible.
  • Ensure that national gas regulations are complied with.
  • Use the appliance only with the intended refrigerant R290.

WARNING!

  • Only allow maintenance and repair work to be carried out on the refrigerant circuit by a qualified technician according to the manufacturer’s specifications.
  • For repair instructions, please contact the Service Centre. Components may only be replaced with identical repair parts.

Product-specifi c hazards

  • Do not place your fingers or other objects into the openings for the air outlet.
  • Do not use the appliance in a room where flammable gases may leak.
  • Do not use the appliance in the bathroom or in other damp environments.
  • Caution with long hair: It can be sucked in by the air flow!
  • Always place and transport the appliance in an upright position. Never use the appliance in an inclined position.
  • Do not use spray cans near the appliance.
  • Never cover the air inlets and air outlets.
  • If you use the condensate drain hose on the condensate drain opening, make sure it is properly mounted and not warped or bent.
  • Make sure that no fabrics such as curtains or similar are hanging or lying near the appliance which could get caught in the appliance.
  • Do not operate the appliance on uneven surfaces or near steps. Avoid tipping the appliance (e.g. due to edges on the floor) during use.
  • Do not operate the appliance near heat sources such as radiators, heat accumulators, ovens or other appliances that generate heat.
  • Check all screw and plug connections at regular intervals!
  • Tighten up loose screws and correct the hold of the plug connections.
  • Do not carry the appliance while it is in use.
  • Do not place or put any objects on the appliance.
  • Do not climb or sit on the appliance.
  • Do not use the appliance in potentially explosive atmospheres. This includes petrol stations, fuel storage areas and areas where solvents are processed. This appliance must also not be used in areas with particle-laden air (for example flour or wood dust).

Noise emissions

  • The sound pressure level of the appliance is less than 63 dB(A).

Storing/transporting

  • Where possible, always transport the appliance upright.
  • After transportation, only connect to the mains and turn on after 24 hours so that the refrigerant circuit can settle after transportation.
  • Always empty the condensate tank and the condensate drain hose before storage and transportation.

Package contents

DANGER!
Risk of choking and suffocation!
Packaging film can be swallowed or used improperly, creating a risk of choking and suffocation.

  • Keep all packaging materials used (film, plastic bags, pieces of polystyrene, etc.) out of the reach of children.
  • Do not allow children to play with the packaging material.
  • Remove the product from the packaging and remove all packaging material.
  • Please check the package contents to ensure that all items are included. If anything is missing, please contact us within 14 days of purchase.
  • The mobile air conditioner must be checked for damage before each use. The following items are supplied with your product:
  • Internal appliance
  • External appliance
  • Connecting hose
  • Bracket for internal appliance
  • Bracket for external appliance
  • Rubber dampers
  • Fixing screws
  • Condensate drainage hose
  • Protective film
  • Short manual

Appliance Overview

  1. Internal appliance
  2. Connecting hose
  3. External appliance
  4. Air outlet
  5. Controls
  6. Intake opening with filter screen
  7. Condensate drainage opening
  8. Filter screen (can be removed by pulling down)
  9. Intake opening
  10. Exhaust air opening
  11. Condensate drainage opening
  12. Switch sleep mode on/offMD-37735-Smart-Medion-Life-P502-FIG-7
  13. Set fan speed
  14. Decrease value
  15. Display
  16. Increase value
  17. Set operating mode
  18. Switch the appliance on/offMD-37735-Smart-Medion-Life-P502-FIG-8
  19. High fan speed enabled
  20. Timer enabled
  21. Display window
  22. Cooling mode enabled
  23. Fan mode enabled
  24. Wireless network enabled
  25. Dehumidification mode enabled
  26. Sleep mode enabled
  27. Low fan speed enabled

Preparing and setting up the air conditioner

Remove all packaging material and check the air conditioner for any damage before you put it into operation.

Warning!
Risk of fire!
The refrigeration system of the appliance contains the natural refrigerant propane (R290).

  • During operation, storage and installation, the room should have an area of at least 4 m² in order to ensure an adequate amount of air in case of damage to the refrigeration system.
  • Please refer to the safety instructions under “Information on refrigerant”.
  • Leave the air conditioner in a vertical position for at least 24 hours before switching on.
  • Operate the air conditioner at an ambient temperature between 5°C and 35°C.
  • Follow the instructions in “3.3. Product-specific hazards” on page 185.

Mounting the condensate drainage hose
The condensate water can be automatically channeled into a suitable container or into a drain.

  • Remove the closure from the condensate outlet.
  • Connect the condensate drainage hose securely and properly and make sure it is not kinked and is free of obstacles.
  • Place the outlet of the condensate drainage hose over a drain or container and ensure that the water can flow out of the appliance unhindered.
  • Do not submerge the end of the hose in water; otherwise, there may be an ‘airlock’ in the hose.
  • To prevent water from leaking, please note that the hose must have a gradient of at least 20%.
  • Secure the hose on the drain or container to prevent uncontrolled water outflow, as the water pressure is very strong and can move the hose.

Mounting the air conditioner

The air conditioner must be mounted on a window. Proceed as described below:

  • Connect the internal and external brackets to the supplied knurled screws, as shown adjacent.

  • Mount the supplied rubber dampers on the back of the external appliance and then screw the external appliance to the outer bracket.

NOTICE!
Possible damage to the appliance!
The appliance can be damaged by falling over.

  • Secure the appliance against falling over!

  • Screw the internal appliance to the holder as well. Use the supplied knurled screws.

  • Now place the protective film around the connecting hose and fasten it with the hook-and-eye fasteners.

  • Now place the complete unit in the window opening and fasten it there with the help of the knurled screws. If necessary, place a cloth or towel underneath to protect the window frame from damage.

The assembly is now complete and the air conditioner is operational.

Operation

Plug the mains plug into a suitable socket.
A beep will sound once you insert the plug. The air conditioner is then in standby mode.

Switch the appliance on/off

  • Press the button to switch the air conditioner on.
  • Press the button again during operation to switch the air conditioner off.
  • Wait about 3 minutes after switching off the air conditioner before switching it on again.

Set operating mode

  • Press the button to switch between operating modes. The indicator light switches between the different operating modes.

The following operating modes are possible:

  • COOLING MODE
  • FAN MODE
  • DEHUMIDIFICATION MODE

Cooling mode
This mode is used to cool the room temperature.

  • This mode is used to cool the room temperature.
  • Select the cooling mode.
  • The indicator light is illuminated.
  • Press the button to set the desired temperature.
  • Press the button to set a high or low fan speed.
  • At a high fan speed, the indicator light illuminates.
  • At a low fan speed, the indicator light illuminates.
  • Cooling mode is switched off automatically if the room temperature is lower than the set temperature. The air conditioner will still ventilate the room. If the room temperature rises, cooling mode starts again.

Fan mode

  • This operating mode is used to circulate the indoor air but does not cool the air.
  • Select the fan mode.
  • The indicator light is illuminated.
  • Press the button to set a high or low fan speed.
  • At a high fan speed, the indicator light illuminates.
  • At a low fan speed, the indicator light illuminates.
  • The temperature and sleep mode cannot be adjusted in fan mode.

Dehumidifi cation mode

  • This operating mode is used to reduce the humidity in the room.
  • Select the dehumidification mode.
  • The indicator light is illuminated.
  • Keep doors and windows closed for better dehumidification performance.
  • The temperature, sleep mode and fan speed cannot be set in dehumidification mode.

Sleep mode
In sleep mode, the fan speed is reduced and the indicator lights are switched off.
Sleep mode can only be enabled in cooling mode.

  • Select the cooling mode.
  • The indicator light is illuminated.
  • Press the button to enable sleep mode.
  • The indicator light is illuminated.

Swing mode

In swing mode, the louvers at the air outlet move automatically to better distribute the air in the room.

  • Press the buttons at the same time to activate the swing mode.
  • Press the buttons again at the same time to deactivate the swing mode.

Setting the timer

Automatic switch-on
You can set the period until the air conditioner automatically switches on in standby mode.

  • Press the button for 3 s to set the desired length of time (1 to 24 hours) until the air conditioner automatically switches on.
  • The indicator light illuminates and “01” (=1 hour) flashes on the display.
  • Press the button to increase the timer.
  • Press the button to decrease the timer.
  • When the hour display stops flashing, your setting is confirmed.
  • The air conditioner switches on automatically after the set time has elapsed.
  • To switch off the timer, press the button again.
  • The indicator light goes out.

Automatic switch-off
When the air conditioner is switched on, you can set the time until it automatically switches off.

  • Press the button for 3 s to set the desired length of time (1 to 24 hours).
  • The indicator light illuminates and “01” (= 1 hour) flashes on the display.
  • Press the button to increase the timer.
  • Press the button to decrease the timer.
  • When the hour display stops flashing, your setting is confirmed.
  • The air conditioner switches off automatically after the set time has elapsed.
  • To switch off the timer, press the button again.
  • The indicator light goes out.

Emptying the condensate tank

CAUTION!
Risk of injury!
There is a risk to health!

  • Do not drink the condensate.

NOTICE!
Material damage!
There is a possibility of material damage due to accidental overflow of condensate.

  • Do not leave the appliance unattended when emptying the condensate tank.

In normal operation, the condensate water evaporates by itself. At high humidity, condensate water can accumulate in the air conditioner. Empty the condensate water collection tank regularly when operating at high humidity and before storing the air conditioner.
The condensate drainage hose supplied only has to be connected in continuous operation and if the air conditioner is operated without supervision in dehumidification mode and during cooling.

  • Switch off the appliance.
  • Remove the seal from the condensate drain opening.
  • Connect the condensate drain hose properly and make sure that it is not kinked and is free of obstacles (not clogged).
  • Place the outlet of the condensate drain hose over a drain or a suitable container (e.g. bucket).
  • Ensure that the condensate can drain out of the appliance unhindered.
  • Do not submerge the outlet of the condensate drain hose in water because an air lock may form in the hose.

To prevent leakage of condensate

  • Since the negative pressure of the condensate tank inside the air conditioner is high, tilt the condensate drain hose down towards the ground (approx. 20 °gradient).
  • Align the condensate drain hose so that it is straight to avoid a siphon in the hose.

Attaching the condensate drainage hose
During continuous operation and unsupervised operation of the air conditioner, the condensate drainage hose supplied must be connected in dehumidification mode and during cooling. The condensate can be automatically drained into a suitable container or drain.

  • Remove the seal from the condensate drain opening.
  • Connect the condensate drainage hose securely and properly and make sure it is not kinked and free of obstacles.
  • Place the outlet of the condensate drainage hose over a drain or container and ensure that the water can flow out of the appliance unhindered.
  • Do not submerge the end of the hose in water; otherwise, there may be an ‘airlock’ in the hose.
  • To prevent water from leaking, please note that the hose must have a gradient of at least 20%.
  • Secure the hose on the drain or container to prevent uncontrolled water outflow, as the water pressure is very strong and can move the hose.

Safety functions

Automatic defrosting

  • At low room temperatures, frost may form on the evaporator during operation. The appliance starts defrosting automatically and the indicator light Power flashes.
  • When the appliance is operated in cooling or dehumidifying mode, the ambient temperature sensor detects that the temperature of the evaporator coil is below – 1°C. Once the compressor stops operating for 10 minutes or the coil temperature has risen to 7°C, the appliance starts back in cooling mode.
  • If the appliance is operated in dehumidification mode and the temperature sensor detects that the temperature of the evaporator is below 40°C and the difference between the appliance’s internal temperature and the room temperature is below 19°C, the appliance starts defrosting for 5 minutes after 20 minutes and the indicator light   Power flashes.

Overload protection
In the event of a power failure, there is a 3-minute delay until the compressor restarts to protect the compressor.

App control

  • To make full use of your air conditioner, download the Medion Life+ app free of charge from the Google Play Store® or Apple® App Store onto your smartphone.
  • Simply scan the following QR code or visit the Play Store (Android™) or App Store (iOS®) and search for “MEDION Life+”.

MD-37735-Smart-Medion-Life-P502-FIG-27

  • A customer account is required to use the app. For this, you need a valid email address. Please follow the instructions in the app.

System requirements

  • Smartphone with WLAN 802.11 b/g
  • 2.4 GHz WLAN network
  • Android™ platform 9 or higher
  • iOS 14 or higher
  • medion Life+ app

The medion Life+ app can only be used to control the appliance using a 2.4 GHz WLAN network. A 5 GHz WLAN network cannot be used for operation.

Setting up the app/connecting to the air conditioner

  • Connect the air conditioner to the mains and turn it on.
  • Open the Medion Life+ app.
  • Press and hold the button on the appliance for 3 seconds until the WLAN symbol starts flashing on the display.
  • If you have not yet registered an appliance in the Medion Life+ app, tap the ADD APPLIANCE button.
  • If you have already connected an appliance in the app, click the button.
  • Select CLIMATE from the list.
  • Select the model MEDION AIR CONDITIONER MD37735 from the overview list.
  • Now follow the instructions in the app to connect.

Alternative connection via appliance hotspot
When using a 5 GHz network or using a 2.4 GHz and 5 GHz network name (SSID), we recommend pairing over a device hotspot to avoid pairing problems.

  • If you have not yet registered an appliance in the Medion Life+ app, tap the ADD APPLIANCE button.
  • If you have already connected an appliance in the app, click the button.
  • Select CLIMATE from the list.
  • Select the model MEDION AIR CONDITIONER MD37735 from the overview list.
  • Then click NEXT.
  • Select the AP mode.
  • Click CONNECT NOW. Leave the LIFE+ app open. Your smartphone’s WLAN settings open automatically.
  • Select the network named SMARTLIFE-XXXX or SL-MEDION-XXXX (XXXX is a placeholder and varies).
  • When you receive the message NO INTERNET CONNECTION, confirm the query ONLY CONNECT THIS TIME (may vary depending on your smartphone’s operating system).
  • Wait until the connection to the WLAN hotspot has been established.
  • Switch back to the Life+ app (the process may vary depending on your smartphone’s operating system: back button, swiping or similar).
  • The process of connecting the air conditioner then starts automatically.

Voice control via Amazon Alexa or Google Assistant

You can operate your appliance via voice control using Amazon Alexa or Google Assistant.

  • Open your Alexa app or Google Assistant and add the Medion Life+ app as a skill.
  • Follow the instructions in the relevant app, sign in with your MEDION customer account and confirm the connection between the Life+ app and the Alexa app or Google Assistant.
  • After authorization, you can operate your appliance via voice control.

Troubleshooting

  • If the appliance stops working properly, please refer to the troubleshooting table shown below to see if you can resolve the problem yourself.
  • Never attempt to repair the appliance yourself. If a repair is necessary, please contact our Service Centre or a suitable authorized repair workshop.
  • Only allow maintenance and repair work to be carried out on the refrigerant circuit by a qualified technician according to the manufacturer’s specifications.
  • For repair instructions, please contact the Service Centre. Components may only be replaced with identical repair parts.
Problem Possible cause Troubleshooting
The appliance is not working. The mains plug is not properly inserted.

Disconnect the mains plug and then plug it in again.
The earthed main socket is faulty.| Check the earthed main socket by connecting another appliance.
unknown error| Contact our Service Centre.
The appliance does not cool down properly.| Windows or doors are open so that warm air can enter the room.|

Close the windows and doors.

The filters are very dirty.| Clean the filters as described under the section on cleaning the filters.

The air outlet is blocked.

| Leave at least 50 cm of space around the appliance in all directions to ensure adequate ventilation.
The operating mode and temperature are not set correctly.| Set the operating mode and temperature to the correct value.
Water leaks out of the appliance.| Overflow when moving the appliance.| Empty the water tank before transportation.
Condensate drainage hose buckled.| Straighten the condensate drain hose.
Problem| Possible cause| Troubleshooting
---|---|---
The appliance is very noisy.| The appliance is on an uneven surface.| Place the appliance on a hard, smooth surface.
There are loose, vibrating parts.| Secure and fasten the parts.
The noise sounds like running water.| Noise is caused by flowing refrigerant. That is normal.
The compressor is not working.| The cooling mode protection is active.| ****

Turn off the appliance and wait 3 minutes before turning it on again.

The overheating protection is active.
Error indicator FL| The pump or float in the internal unit is defective.|


Contact our Service Centre.

Error indicator E1| Failure of the room temperature sensor.| Contact our Service Centre.
Error indicator E2| Failure of the system temperature sensor.| Contact our Service Centre.
Error indicator EF| Engine defect Internal appliance.| Contact our Service Centre.
Error indicator Eb| Cooling medium level too low.| Contact our Service Centre.
Error indicator E4| Frost protection is active.| Contact our Service Centre.

Cleaning

WARNING!
Risk of electric shock!
There is a risk of electric shock due to live parts.

  • The appliance must not be immersed in water or other liquids, or held under running water, because this could cause an electric shock.
  • Unplug the mains plug from the socket before you start cleaning the appliance.
  • Make sure that no liquids enter the appliance.

WARNING!
Risk of injury!
There is a risk of cuts due to contact with sharp-edged rotor blades inside the housing.

  • Do not disassemble the appliance to clean the rotor blades.

NOTICE!
Damage to the appliance!
The improper use of cleaning agents on the appliance may damage the surfaces.

  • Do not use chemical solutions or cleaning agents because these may damage the surface or the labels on it.
  • Do not use aggressive, chemical or abrasive cleaning agents and do not use hard sponges.
  • Press the button to turn off the air conditioner.
  • Pull the mains plug out of the socket.
  • Clean the housing only with a soft, damp cloth or a soft, thin kitchen towel.
  • Moisten the cloth with mild soapy water to remove stubborn dirt.
  • Dry the housing carefully before switching on the appliance.

Cleaning the fi lter screens

NOTICE!
Damage to the appliance!
Dust collects on the filter screens and restricts the air flow. The restricted air flow reduces the efficiency of the appliance. In case of excessive accumulation of dust, the filter can be blocked and material damage to the appliance can occur.

Clean the filter screens regularly (at least every 2 weeks) as described below.

Never operate the appliance without the filter screens in place; otherwise the evaporator inside may become contaminated.

  • Press the button to turn off the air conditioner.
  • Pull the mains plug out of the socket.
  • Remove the filter screen from the appliance.
  • Use a vacuum cleaner to vacuum dust from the filter screens.
  • Turn the filter screens around and rinse the filter screens under running water. Run the water in the opposite direction of the air flow through the filter screen.
  • Set the filter screens aside and allow them to air dry completely.

WARNING!
Risk of injury!
There is a risk of cuts due to contact with the sharp-edged evaporator surface when installing the filter screens.

  • Do not touch the sharp-edged evaporator surface with your bare hands.
  • Insert the dried filter screens back into the appliance.

Prolonged non-use and storage
If the air conditioner is not used for a prolonged period, the air conditioner must be cleaned and fully dried.

NOTICE!
Damage to the appliance!
The evaporator inside the appliance must be dried before storage to prevent damage to components or mould formation.

Turn off the air conditioner, unplug the outlet and leave the air conditioner to dry for several days in a dry, well-ventilated place, or use the air conditioner to dry for a few hours until the condensate drain is dry.

  • Press the button to switch the air conditioner on.
  • Select the fan mode. The indicator light is illuminated.
  • Keep the air conditioner running in fan mode for a few hours so that it dries completely from the inside.
  • Press the button to switch the air conditioner off.
  • Pull the mains plug out of the socket.
  • Remove and clean the filter screens and allow them to dry out completely.
  • Insert the filter screen back into the frame provided for this in the housing.
  • If possible, store the air conditioner and its accessories in the original packaging in a dark, ventilated, dry and frost-free internal room.
  • Store the air conditioner in a room without continuously operating heat sources (such as naked flames, gas appliances or electric heating).

Disposal

PACKAGING

  • Your appliance has been packaged to protect it from damage in transit. The packaging is made of materials that can be recycled in an environmentally friendly manner.
  • Observe the following labels on the packaging materials regarding waste separation with the abbreviations (a) and numbers (b): 1–7: plastics/20–22: paper and cardboard/80–98: composite materials
  • (France only) The “Triman” symbol tells the consumer that the product can be recycled, is covered by an extended system of manufacturer’s responsibility and must be sorted by material type in France.

APPLIANCE

  • All old appliances marked with the symbol shown must not be disposed of in normal household waste.
  • In accordance with Directive 2012/19/EU, the appliance must be properly disposed of at the end of its service life.
  • This involves separating the materials in the appliance for the purpose of recycling as well as minimising the environmental impact and negative effects on human health
  • Take old appliances to an electrical scrap collection point or a recycling centre.
  • Contact your local waste disposal company or your local authority for more information on this subject.

The refrigerant R290 must not enter the environment.

BATTERIES

  • Do not dispose of used batteries with normal household rubbish.
  • Batteries must be disposed of correctly. For this purpose, retailers that sell batteries and local collection points provide containers in which you can dispose of them. Contact your local waste disposal company or your local authority for more information.
  • In connection with the sale of batteries or the supply of appliances containing batteries, we are obliged to draw your attention to the following:
  • As the end user, you are legally required to return used batteries.
  • The crossed-out wheelie bin symbol means that the battery must not be disposed of with household rubbish.

Technical specifications

Air conditioner

Model| MD 37735


Distributor

| MEDION AG

Am Zehnthof 77

45307 Essen Germany

Commercial register number| HRB 13274
Power supply| AC 220–240 V~ 50 Hz
Rated power| 560 W
Cooling capacity| 5000 BTU
Refrigerant| R290
Refrigerant quantity| 130 g
Power levels| 2
Maximum room size| Approx. 12 m²
Air throughput| 280 m³/h
Dehumidification performance| Approx. 0.5 L/h
Dimensions of internal appliance (W×H×D)| 445 × 310 × 190 mm
Dimensions of external appliance (W×H×D)| 440 × 355 × 210 mm
Weight of internal appliance| Approx. 5.6 kg
Weight of external appliance| Approx. 14.4 kg
Operating volume| <63 dB(A)
WLAN interface for wireless communication

Standard| 802.11 b/g/n
Encryption| WEP/WPA/WPA2
Frequency range| 2400–2480.5 MHz
Max. transmission power| 17 dBm
Channel| 1–13
---|---

Product data sheet

MD-37735-Smart-Medion-Life-P502-FIG-36 MD-37735
-Smart-Medion-Life-P502-FIG-37

EU declaration of conformity

  • MEDION AG hereby declares that the radio equipment type MD 37735 complies with Directive 2014/53/EU as well as Directive 2009/125/EC and Directive 2011/65/EU.
  • The complete EU declaration of conformity is available at: www.medion.com/conformity.

Service information

Please contact our Customer Service team if your device ever stops working the way you want or expect it to. There are several ways for you to contact us:

  • In our Service-Community, you can meet other users, as well as our staff, and you can exchange your experiences and pass on your knowledge there.
  • You will find our Service-Community at community.medion.com.
  • Alternatively, use our contact form at www.medion.com/contact.
  • You can also contact our Service team via our hotline or by post.
Opening times Hotline number UK

Mon – Fri: 08.00 – 20.00

Sat – Sun: 10.00 – 16.00

|  0333 3213106
Service address
MEDION Electronics Ltd.

120 Faraday Park, Faraday Road, Dorcan Swindon SN3 5JF, Wiltshire

United Kingdom

  • You can download this and many other sets of operating instructions from our service portal at www.medionservice.com.
  • We have stopped providing printed copies of our warranty terms and conditions as part of our commitment to sustainability, but you can access the warranty terms and conditions on our service portal.
  • You can also scan the QR code on the side of the screen, to download the operating instructions onto your mobile device from the service portal.

MD-37735-Smart-Medion-Life-P502-FIG-38

Legal Notice

  • Copyright © 2024
  • Date: 09. January 2024
  • All rights reserved.
  • These operating instructions are protected by copyright.
  • Mechanical, electronic and any other forms of reproduction are prohibited without
  • the written permission of the manufacturer.
  • Copyright is owned by the company:
  • MEDION AG
  • Am Zehnthof 77
  • 45307 Essen
  • Germany

Please note that you cannot use the address above for returns. Please always contact our Customer Service team first.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals