KNIGHT MX PLUS Facility Solutions Owner’s Manual

August 10, 2024
KNIGHT

KNIGHT MX PLUS Facility Solutions

Specifications

  • Flow Rates: 1 GPM (3.8 LPM) bottle fill, 4 GPM (15.2 LPM) bucket fill
  • Back Flow Prevention: Flex-Gap or Aire-Gap
  • Optimal Min. Pressure: 30 PSI (2 bar)
  • Optimal Max. Pressure: 60 PSI (4 bar)
  • Certifications: A.S.S.E., I.A.P.M.O. (UPC)

Product Usage Instructions

Dispensing Activation and Operation
Dispensing is activated by pushing the large buttons on the MX Plus dispenser. To lock the dispenser into the on position for hands-free dispensing, engage the catch. To stop the flow, press the button again and release it. Fill spray bottles by pushing them against the actuator bar with one hand.

Reconfiguring the MX Plus Dispenser
The MX Plus dispenser can be reconfigured in several ways without the need for tools. To swap the water inlet from one side to the other, perform a quarter turn of the water quick connect.

For changing engine configurations, follow these steps:

  1. Slide the engine assembly out of the snap guides.
  2. Remove the single product engine with a quarter turn.
  3. Replace it with a dial-4 assembly.
  4. Pop out the blanking plate from the cover to reveal a round hole for the dial selector.
  5. Connect your four chemical supply lines and replace the snap-on cover.

INSTRUCTION

MX Plus dispensers are field serviceable and highly flexible proportions, offering configurations that allow for up to eight products and two flow rates with a choice of Flex-Gap or Aire-Gap backflow prevention.
Dispensing is activated by pushing smooth-operating large buttons that can be locked into the on position for hands-free dispensing. Simply engage the catch to keep the flow open then press the button again and release to stop the flow. Spray bottles can be filled using one hand by pushing the bottle against the actuator bar.

  • One-engine and two-engine cabinets are available and may be equipped with either a single product engine or a dial 4 selector engine for each button. Designed for flexibility, each MX Plus can be reconfigured in several ways in the field without tools.
  • The water inlet can be quickly swapped from one side to the other with a simple quarter turn of the water quick connect. Single-product engines can be replaced with a dial 4 selector engine in a few simple steps: Slide the engine assembly out of the snap guides. Remove the single product engine with a quarter turn. Replace with a dial-4 assembly. Pop out the blanking plate from the cover to reveal a round hole for the dial selector.
  • Connect your four chemical supply lines and replace the snap-on cover.

KEY BENEFITS

  • Tool-less Components – ¼ turn connections; double O-ring design
  • Snap-on Cover
  • Large, easy-to-use paddles with locking catch
  • Engines slide into snap-guides for easy service and re-configuration
  • Easily serviced diaphragm with ¼ turn cover
  • Compact footprint
  • Both Aire-Gap and Flex-Gap backflow devices meet national and local codes

TECHNICAL DATA

  • Flow Rates
    • 1 GPM (3.8 LPM) bottle fill 4 GPM (15.2 LPM) bucket fill
  • Back Flow Prevention Flex-Gap or Aire-Gap
  • Max. Water Temperature 140° F (60° C)
  • Optimal Min. Pressure 30 PSI (2 bar)
  • Optimal Max. Pressure 60 PSI (4 bar)
  • Certifications
    • A.S.S.E.
    • I.A.P.M.O. (UPC)

Features

  • One hand bottle fill
  • Large, ergonomic buttons
  • Easy slide lock and release catch for buttons
  • Built-in Flow-Control technology for accurate dilution in varying water pressures
  • Snap On/Off cover
  • Included tip kit and poly tubing, foot valves and product labels
  • Optional compression, John Guest, or barb fittings available

VALVE ASSEMBLY

ACCESSORIES

INSTALLATION

FOR MORE INFORMATION

FAQ

  • Q: Can I replace a single product engine with a dial 4 selector engine in the field?
    • A: Yes, you can easily replace a single product engine with a dial 4 selector engine by following the steps outlined in the user manual. No additional tools are required for this process.
  • Q: How can I fill spray bottles using the MX Plus dispenser?
    • A: You can fill spray bottles using one hand by pushing the bottle against the actuator bar of the MX Plus dispenser. This allows for easy and efficient filling operations.
  • Q: Is it possible to reconfigure the MX Plus dispenser without using any tools?
    • A: Yes, the MX Plus dispenser is designed for flexibility, and it can be reconfigured in several ways in the field without the need for any tools. Simply follow the instructions provided in the user manual for reconfiguration.