Bright 018621 Foot Massager Instruction Manual
- June 3, 2024
- Bright
Table of Contents
- Bright 018621 Foot Massager
- SAFETY INSTRUCTIONS
- AMBIENT CONDITIONS
- PERSONS WHO SHOULD NOT USE THE PRODUCT
- CONTROL PANEL
- SYMBOLS
- TECHNICAL DATA
- DESCRIPTION
- FUNCTIONS
- USE
- BEFORE USE
- HOW TO USE
- Warming function
- Intensity
- Mode
- Time
- MAINTENANCE
- STORAGE
- TROUBLESHOOTING
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Bright 018621 Foot Massager
Jula AB reserves the right to make changes to the product. Jula AB claims copyright on this documentation. It is not allowed to modify or alter this documentation in any way and the manual shall be printed and used as it is in relation to the product. For the latest version of operating instructions, refer to the Jula website.
SAFETY INSTRUCTIONS
Read these instructions carefully before use, and save them for future reference. Failure to follow the instructions below can result in a risk of burn injuries, fire, electric shock and/or personal injury.
- Pull out the plug after use and before cleaning.
- Be careful when using the warming mode – risk of burn injury.
- Do not use the product on areas of skin with reduced sensitivity, or on parts of the body with poor circulation of blood.
- Incorrect use can result in a risk of personal injury. Do not allow children or persons with functional disorder to use the warming mode.
- Never use the product under a cushion, or blanket – risk of fire, electric shock and/or burn injury.
- Do not cover the product when in use – risk of overheating and personal injury.
- The product is not intended to be used by persons (children or adults) with any form of functional disorders, or by persons who do not have sufficient experience or knowledge on how to use it, unless they have received instructions concerning the use of the product from someone who is responsible for their safety.
- Stop using the product immediately if you experience discomfort.
- Do not use the product if the power cord or plug are damaged, if the product is not working properly, if it has been exposed to water, or if it is damaged in any other way. Take the product to an authorised service centre to have it checked, and if necessary repaired.
- Only use spare parts recommended by the manufacturer.
- Do not poke any objects into the openings on the product.
- Switch off all the buttons before pulling out the plug.
- The product must not be used for diagnosis or treatment. Seek medical attention for diagnosis and/or treatment.
AMBIENT CONDITIONS
- Do not use the product in damp or wet areas – risk of material damage.
- Do not use the product in an ambient temperature of more than 40°C.
- Do not use the product outdoors.
- Do not use the product in direct sunlight or near an oven, gas heater, radiator or other sources of heat.
PERSONS WHO SHOULD NOT USE THE PRODUCT
-
Persons with any of the following conditions should consult a doctor before using the product.
-
Persons undergoing medical treatment and persons who experience physical discomfort.
-
Persons with high blood pressure, heart disease, cerebral atherosclerosis or cerebral thrombosis.• Persons who have cancer.
Persons who are pregnant or menstruating. -
Persons who have osteoporosis.
-
Persons who have a pacemaker or other medical implants.
-
Persons suffering from acute illness.
-
Minors.
CONTROL PANEL
- Do not touch the control panel with wet hands.
- Do not expose the control panel to water or any other liquid.
- Avoid falling asleep during use.
- Do not use the product if you under the influence of drugs, alcohol or medication, or if you experience discomfort.
- Do not put the massage pad in direct contact with your hands, feet, joints, knees, breast or abdomen.
- Do not use the product for more than 30 minutes.
- Do not use the product if the protective cover is damaged.
- Do not use the product 1 hour before or after eating
- risk of discomfort.
- Do not activate warming mode if the product is used in an area with low temperature. Wait until a normal temperature is reached before warming mode is activated.
- Condensation can form inside the product if it is moved from a cold to a warm room, which can damage the product and/or result in malfunction. Wait at least 1 hour, until the product has assumed room temperature, before starting the product.
SYMBOLS
TECHNICAL DATA
- Rated voltage: 230 V ~ 50 Hz
- Output: 45 W
- Cord length: 1.8 m
- Size: W22 x H36 x D42 cm
DESCRIPTION
Massage and warming of feet. Three programmes and five pressure levels for adjustable comfort. With adjustable timer, 5 to 30 minutes. With alternative to select warming mode on or off during massage.
FUNCTIONS
- Control panel
- Five buttons to set and control functions.
- Central massage pad
- Massage and warmth for arches.
- Front massage pad
- Massage for front of feet.
- Back massage pad
- Massage for heels.
- Air cushion for pressure on ankles.
- Removable, washable protective cover.
- Underside with cord holder for simple storage.
USE
SETTINGS
- A. TIME
- Setting of massage time.
- B. MODE
- Mode P1: Mechanical massage and air massage.
- Mode P2: Mechanical massage only.
- Mode P3: Air massage only.
- C. POWER (Power switch)
- Switch on/off.
- D. HEAT
- Function for comfortable warmth.
- E. LEVEL (Intensity)
- There are 5 intensity modes, L1 to L5.
BEFORE USE
- Check the product for damage.
- Make sure to sit comfortably when using the product.
HOW TO USE
Unwind the cord from the holder on the underside of the product and plug the plug into a power point.
Warming function
Press the power switch to start the product in mode one (1) with activated warming function and low intensity. Press the power switch again to deactivate the warming function.
Intensity
When the product is on, press the intensity button to set the required intensity.
Mode
When the product is on, press the mode button to set the required mode.
Time
When the product is on, press the time button to set the required massage time, from 5 to 30 minutes.
MAINTENANCE
WARNING!
Switch off the product and pull out the plug before cleaning.
- Keep the product clean. Do not expose the product to moisture.
- Clean the casing with a dry cloth.
NOTE:
Do not use detergent that contains benzene, petrol, thinner, or other strong
solvents.
STORAGE
- Store the product in the packaging in a dry, cool and well-ventilated area.
- Avoid twisting or folding the power cord.
- Do not hang up the product with the power cord.
- Keep the product away from sharp objects that can scratch the surface.
- Do not expose the product to direct sunlight or heat.
- Cover the product with a suitable dust cover (sold separately) if it is not going to be used for some time.
TROUBLESHOOTING
The troubleshooting guide is used to identify the causes of common problems and how they can be rectified. Contact the retailer if the problem cannot be rectified with the help of the troubleshooting guide.
Problem | Possible cause | Proposed action |
---|
The product does not work.
|
The plug is not plugged in.
| Check that the plug is correctly plugged in and that the power point is
supplied with voltage.
The power switch has not been pressed in.| Press the power switch.
The product switches off unexpectedly.
|
Power failure.
| Check that the plug is correctly plugged in and that the power point is
supplied with voltage.
The set massage time has expired.| Start the product again.
Overheating.| Allow the product to cool and then switch on again.
Excessively high pressure on the massage rollers.| Start the product again.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>