Specifications
- Brand: Ermenrich
- Model: Ping MK10
- Type: Digital Clamp Meter
- Power Source: 2 AAA batteries
FAQ
- Q: What should I do if the device does not turn on?
- A: Check the battery compartment to ensure batteries are inserted correctly and that they have charge. If issues persist, refer to the user manual for troubleshooting steps.
- Q: How do I calibrate this digital clamp meter?
- A: Calibration instructions can be found in the user manual. It is recommended to calibrate the device periodically to maintain accuracy.
Overview
- Clamp
- Trigger
- LED indicator
- Knob switch
- FUNC (Function) button
- MAX (Maximum value) button
- H/ button (Data hold/Backlight)
- LCD display
- COM jack (−)
- INPUT jack (+)
- Battery compartment
Please carefully read the safety instructions and the user manual before using this product. Use the device only as specified in the user manual. Keep away from children.
Kit Includes
The kit includes: digital clamp meter, test leads, carry bag, user manual, and warranty.
Getting started
Open the battery compartment cover (11) and insert 2 AAA batteries according to the correct polarity. Close the cover.
Usage
Use the knob switch (4) to turn the device on and to select the required operation mode:
- OFF – off position;
- 200 A~/20A~/2A~ – AC measurement (within a specified range);
- – AC voltage measurement;
- – DC voltage measurement;
- – resistance measurement;
- – continuity test, diode test.
Press the FUNC button (5) to switch between the functions. When the device is
off, press and hold (5) for 3 seconds to enable/disable the auto-off option,
and then observe the corresponding symbol on the screen. When the auto-off
option is enabled, the device will automatically turn off in 15 minutes.
Press the MAX button (6) to switch to maximum values. Press and hold (6) for 3
seconds to exit this function.
Press the H/ button (7) to hold the display readings (H appears on the
screen). Press and hold (7) for 3 seconds to turn the backlight on/off.
AC measurement
Turn the knob switch (4) to the 200 A~, 20A~, or 2A~ position according to the current measurement limit. Press the trigger (2) to open the clamps (1) and fully enclose the conductor to be measured. Then slowly release the trigger (2). In order to ensure the measurement accuracy, the measured conductor must be placed in the center of the clamps. The measurement results will appear on the LCD screen (8).
If the measurement result is >3A, the orange backlight will turn on.
For the following measurements using test leads, turn the knob switch (4) to the appropriate position. Plug the black test lead into the COM jack (9) and the red test lead into the INPUT jack (10).
AC/DC voltage measurement
- Turn the knob switch (4) to the (AC voltage) or (DC voltage) position. Connect the probes to the measuring points. The measurement results will appear on the LCD screen (8).
If the measurement result is >80V, the orange backlight will turn on.
Resistance measurement
- Turn the knob switch (4) to the position. Connect the probes to the resistance measuring points of circuit or resistor. The measurement results will appear on the LCD screen (8).
Before measurement, make sure that the power supply is disconnected and the capacitor in the circuit is completely discharged.
Continuity test
- Turn the knob switch (4) to the position. Press the FUNC button (5) until symbol appears on the screen. Connect the probes to the circuit or component to be tested. The measurement results will appear on the LCD screen (8).
If the resistance is <30Ω, an acoustic signal will be emitted continuously and the LED indicator (3) will light up.
Diode test
Turn the knob switch (4) to the position. Press the FUNC button (5) until symbol appears on the screen. Connect the black test probe to the cathode side and the red test probe to the anode side of the diode to be measured. The measurement results will appear on the LCD screen (8).
If the polarity of the test probes is reverse to the diode polarity, the OL (Overload) will appear on the screen. This can be used for distinguishing the anode and cathode side of a diode.
Specifications
DC voltage range | 200mV / 2V / 20V / 200V / 600V ±(0.5%+5) |
---|---|
AC voltage range | 2V / 20V / 200V / 600V / ±(1.0%+5) |
AC current range | 2A / 20A / 200A ±(2.5%+8) |
Resistance range | 200Ω / 2kΩ / 20kΩ / 200kΩ / 2MΩ / 20MΩ ±(1.0%+5) |
Counts | 2000 |
Clamp opening size | 25mm |
Operating temperature range | 0… +40°C (+32… +104°F) |
Storage temperature range | –10… +60°C (+14… +140°F) |
Power supply | 2pcs AAA 1.5V alkaline batteries |
Safety rating | EN61010-1,-2-030; EN61010-2-033; EN61326-1; Cat. III, 600V |
Auto-off | 15min. |
Dimensions | 164x61x30mm |
Weight | 125g |
The manufacturer reserves the right to make changes to the product range and specifications without prior notice.
Care And Maintenance
Do not use the device if it is damaged or does not operate properly. Use extreme caution when voltages exceeding the true RMS value of 30V AC, the peak voltage of 42V AC, or 60V DC are present. Such voltages may result in electric shock. The voltage applied between the test terminals or between any terminal and the ground shall not exceed the nominal value specified in the technical data sheet. Do not expose the device to rain or wet conditions. Do not use the device in potentially explosive rooms. Do not use the device in aggressive atmosphere.
Do not open the device. Replace the battery as soon as the low battery indicator lights up. Follow local and national safety regulations when working in hazardous locations. Protect the device from sudden impact and excessive mechanical force. Never attempt to operatea damaged device or a device with damaged electrical parts! Only use accessories and spare parts for this device that comply with the technical specifications. If a part of the device or battery is swallowed, seek medical attention immediately.
Battery Safety Instructions
Always purchase the correct size and grade of battery most suitable for the intended use. Always replace the whole set of batteries at one time; taking care not to mix old and new ones, or batteries of different types. Clean the battery contacts and also those of the device prior to battery installation. Make sure the batteries are installed correctly with regard to polarity (+ and –). Remove batteries from equipment that is not to be used for an extended period of time. Remove used batteries promptly. Never short-circuit batteries as this may lead to high temperatures, leakage, or explosion. Never heat batteries in order to revive them. Do not disassemble batteries. Remember to switch off device after use. Keep batteries out of the reach of children, to avoid risk of ingestion, suffocation, or poisoning. Utilize used batteries as prescribed by your country’s laws.
Ermenrich Warranty
Ermenrich products, except for their accessories, carry a 5-year warranty against defects in materials and workmanship. All Ermenrich accessories are warranted to be free of defects in materials and workmanship for six months from the purchase date. The warranty entitles you to the free repair or replacement of the Ermenrich product in any country where a Levenhuk office is located if all the warranty conditions are met.
For further details, please visit:
levenhuk.com/warranty
If warranty problems arise, or if you need assistance in using your product,
contact the local Levenhuk branch.
Contact
- Levenhuk Optics s.r.o. (Europe): V Chotejně 700/7, 102 00 Prague 102, Czech Republic, +420 737-004-919, sales-info@levenhuk.cz
- Levenhuk USA 928 E 124th Ave. Ste D, Tampa, FL 33612, USA, +1 813 468-3001, contact_us@levenhuk.com
- Levenhuk®, Ermenrich® are registered trademarks of Levenhuk Optics s.r.o. (Europe).
© 2006–2024 Levenhuk, Inc. All rights reserved.
ermenrich.com
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>