RICE LAKE WEIGHING SYSTEMS SCT-2200 Signal Conditioning Weight Transmitter User Guide

August 2, 2024
RICE LAKE WEIGHING SYSTEMS

RICE LAKE WEIGHING SYSTEMS SCT-2200 Signal Conditioning Weight Transmitter

Key Functions

Key Function

ZERO

| In setup: scroll forward through parameters
In numeric input: decreases digit to be modified

TARE

| In setup: scroll back through the functions
In numeric input: increases digit to be modified
Key| Function
---|---

MODE

| In setup: quickly position the first step of a menu
In numeric input: selects digit to be modified, from
left to right

PRINT

| In setup: enter into a parameter or to confirm a
setting
In numeric input: confirms the entry made
Key| Function
---|---

ON/OFF

| Turn the instrument on/off
In setup: exit a step without confirming the setting In numeric input: clears the present value

Setup Menu

  1. Press the ON/OFF key ( ) to turn the instrument on.
  2. Press the mode key ( ) when the firmware version displays to enter the setup menu.
  3. Press the print key ( ) in the setup menu to view/select the parameter choices.

Default Factory Calibration

The instrument has a default calibration with the following features:
Capacity = 10,000 kg
Load cell sensitivity = 2.000mV/V
Divisions = 1
Theoretical Calibration
Use parameters to perform a theoretical calibration.
For parameters & press and wait for ERNOT, STORE?. Then press to accept.
For parameter apply test weight before pressing .
Calibration Using Known Weight
Use parameters to perform a standard calibration with a known weight.
Setpoint Programming
In the weigh mode, press and hold to access output’s setpoint programming.

NOTE: When settings are complete press until the indicator displays . Press to save set up and return to weigh mode. Pressing any other key exits the setup and discards changes.

Wiring Diagram

Pin Number Label Description

VE 12-24 VDC Power Supply
1| GND| 0 VDC (GND)
2| +VDC| +12-24 VDC
Inputs and Outputs
Outputs (48 VAC or 60 VDC, 150 mA max)
3| OUT1| Output 1
4| OUT2| Output 2
5| COMOUT| Common Output
opt isolated Inputs Positive Logic (12-24 VDC, 5-20 mA max)
6| IN1| Input 1
7| IN2| Input 2
 | Connect input common to ground
Analog Output (PN 202104 only)
Voltage
8| V+| +10 V
9| V-| 0 V (GND)
Current
10| I+| +20 mA
11| I-| -0 mA (GND)
NOTE: Max. resistance on output current: 350 Ω Min. resistance on output voltage: 10 kΩ
Serial Port
RS-232
12| TX| Transmission
13| RX| Reception
14| GND| Ground
RS-485
RJ45 Plug-IN/OUT| 485 Line
RJ45 Plug-IN/OUT| 485 Line
Load Cell Connections
15| SIG+| Signal +
16| SIG-| Signal –
17| SEN+| Sense +
18| SEN-| Sense –
19| EXC+| Excitation +
20| EXC-| Excitation –

CUSTOMER SUPPORT

© Rice Lake Weighing Systems
Content subject to change without notice.
230 W. Coleman St. • Rice Lake, WI 54868 • USA
USA: 800-472-6703 • International: +1-715-234-9171
June 6, 2024
www.ricelake.com
PN 184974 Rev C

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

RICE LAKE WEIGHING SYSTEMS User Manuals

Related Manuals