RICE LAKE WEIGHING SYSTEMS CW-90X Checkweigher Instruction Manual

June 1, 2024
RICE LAKE WEIGHING SYSTEMS

RICE LAKE WEIGHING SYSTEMS CW-90X Checkweigher

RICE-LAKE-WEIGHING-SYSTEMS-CW-90X-Checkweigher-PRODUCT

Specifications

  • Product Name: CW-90X Checkweigher
  • Part Kit Components (PN 222569):
    • 182479 – Metal breather vent
    • 182480 – Metal breather vent nut
    • 222514 – Adhesive threadlocker
  • Date: March 22, 2024
  • Model Number: PN 223213 Rev A

Product Usage Instructions

  1. Remove the backplate nuts with a screwdriver.
  2. Remove the backplate from the enclosure.
  3. Use an 18 mm wrench to hold the old vent in place.
  4. Use a 15 mm socket wrench to loosen the nut and remove the old breather vent.
  5. Apply a small amount of adhesive threadlocker on the new breather vent threads.
  6. Insert the breather vent through the hole with threads facing the inside of the unit.
  7. Use an 18 mm wrench to hold the breather vent.
  8. Use a 15 mm socket wrench to secure the metal nut onto the breather vent threads.
  9. Ensure the nut is tightened to 10 in-lb.
  10. Reattach the back cover.

TOOLS AND PARTS

Tool List

  • Phillips screwdriver
  • 18 mm wrench
  • 15 mm socket wrench
  • 10 in-lb torque wrench

Part List

  • Metal breather vent
  • Metal breather vent nut
  • Adhesive threadlocker
Part Number Description
182479 Metal breather vent
182480 Metal breather vent nut
222514 Adhesive threadlocker

USING INSTRUCTION

Perform the following steps to replace the breather vent:

  1. Remove the backplate nuts with the screw driver (see Figure 2).RICE-LAKE-WEIGHING-SYSTEMS-CW-90X-Checkweigher-FIG-2
  2. Remove the backplate from the enclosure.
  3. Use the 18 mm wrench to hold the old vent in place.
  4. Use the 15 mm socket wrench to loosen the nut and remove the old breather vent.
  5. Apply a small amount of the adhesive threadlocker on the new breather vent threads (see Figure 3).
  6. Insert the breather vent through the hole with threads facing the inside of the unit.
  7. Use the 18 mm wrench to hold the breather vent.
  8. Use the 15 mm socket wrench to secure the metal nut onto the breather vent threads (see Figure 4).RICE-LAKE-WEIGHING-SYSTEMS-CW-90X-Checkweigher-FIG-4 IMPORTANT: Ensure the nut is tightened to 10 in-lb.
  9. Reattach back cover.

NOTE: See the CW-90/90X Technical Manual (PN 105942) for more information on rear cover bolt torque specification and tightening pattern.

Manuals are available from Rice Lake Weighing Systems at www.ricelake.com/manuals
Warranty information is available at www.ricelake.com/warranties

FAQ

  • Q: Where can I find more information about rear cover bolt torque specification and tightening pattern?
    A: Refer to the CW-90/90X Technical Manual (PN 105942) for detailed information on rear cover bolt torque specification and tightening pattern.

For additional assistance or inquiries, please visit our website at www.ricelake.com.