RICE LAKE WEIGHING SYSTEMS CW-90X Checkweigher Instruction Manual
- June 1, 2024
- RICE LAKE WEIGHING SYSTEMS
Table of Contents
RICE LAKE WEIGHING SYSTEMS CW-90X Checkweigher
Specifications
- Product Name: CW-90X Checkweigher
- Part Kit Components (PN 222569):
- 182479 – Metal breather vent
- 182480 – Metal breather vent nut
- 222514 – Adhesive threadlocker
- Date: March 22, 2024
- Model Number: PN 223213 Rev A
Product Usage Instructions
- Remove the backplate nuts with a screwdriver.
- Remove the backplate from the enclosure.
- Use an 18 mm wrench to hold the old vent in place.
- Use a 15 mm socket wrench to loosen the nut and remove the old breather vent.
- Apply a small amount of adhesive threadlocker on the new breather vent threads.
- Insert the breather vent through the hole with threads facing the inside of the unit.
- Use an 18 mm wrench to hold the breather vent.
- Use a 15 mm socket wrench to secure the metal nut onto the breather vent threads.
- Ensure the nut is tightened to 10 in-lb.
- Reattach the back cover.
TOOLS AND PARTS
Tool List
- Phillips screwdriver
- 18 mm wrench
- 15 mm socket wrench
- 10 in-lb torque wrench
Part List
- Metal breather vent
- Metal breather vent nut
- Adhesive threadlocker
Part Number | Description |
---|---|
182479 | Metal breather vent |
182480 | Metal breather vent nut |
222514 | Adhesive threadlocker |
USING INSTRUCTION
Perform the following steps to replace the breather vent:
- Remove the backplate nuts with the screw driver (see Figure 2).
- Remove the backplate from the enclosure.
- Use the 18 mm wrench to hold the old vent in place.
- Use the 15 mm socket wrench to loosen the nut and remove the old breather vent.
- Apply a small amount of the adhesive threadlocker on the new breather vent threads (see Figure 3).
- Insert the breather vent through the hole with threads facing the inside of the unit.
- Use the 18 mm wrench to hold the breather vent.
- Use the 15 mm socket wrench to secure the metal nut onto the breather vent threads (see Figure 4). IMPORTANT: Ensure the nut is tightened to 10 in-lb.
- Reattach back cover.
NOTE: See the CW-90/90X Technical Manual (PN 105942) for more information on rear cover bolt torque specification and tightening pattern.
Manuals are available from Rice Lake Weighing Systems at
www.ricelake.com/manuals
Warranty information is available at
www.ricelake.com/warranties
FAQ
- Q: Where can I find more information about rear cover bolt torque specification and tightening pattern?
A: Refer to the CW-90/90X Technical Manual (PN 105942) for detailed information on rear cover bolt torque specification and tightening pattern.
For additional assistance or inquiries, please visit our website at www.ricelake.com.
© Rice Lake Weighing Systems Content is subject to change without notice.
230 W. Coleman St.
- Rice Lake, WI 54868
- USA USA: 800-472-6703
- International: +1-715-234-9171
- Visit our website www.RiceLake.com