RICE LAKE WEIGHING SYSTEMS PN 178027 Automated Ticketing Kiosk HID Reader Interface Board Instruction Manual
- June 2, 2024
- RICE LAKE WEIGHING SYSTEMS
Table of Contents
- HID Reader/Interface Board Installation
- FCC Compliance
- Parts Breakdown
- Remove Old HID Reader (if needed)
- Mount the New Mounting Plate
- Secure The Reader To The Mounting Plate
- Wiring
- Test Reader
- Specifications
- CUSTOMER SUPPORT
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
RICE LAKE WEIGHING SYSTEMS PN 178027 Automated Ticketing Kiosk HID Reader Interface Board
HID Reader/Interface Board Installation
HID® reader/interface board kits (PN 176452 and 214915) replace RFID readers
on kiosks with HID® Signo™ readers.
HID® Signo™ readers offer a secure and flexible platform that stores and
retrieves data using a special card/badge. Kits PN 176452 and 214915 are
similar and only vary in card reader parts (see page 2). What differentiates
installation, is wiring and power supply requirements (see page 5). Kit 176452
requires a 10-16 VDC power supply (sold separately) while 214915 uses power
from the indicator.
Manuals and additional resources are available from Rice Lake Weighing Systems
at www.ricelake.com/manuals Warranty
information can be found at
www.ricelake.com/warranties
WARNING: To avoid shock or serious injury, consult a licensed electrician
for electrical installation procedures.
FCC Compliance
United States
This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference when
the equipment is operated in a commercial environment. This equipment
generates, uses, and can radiate radio frequency energy and, if not installed
and used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in a
residential area is likely to cause harmful interference in which case the
user will be required to correct the interference at his own expense.
Canada
This digital apparatus does not exceed the Class B limits for radio noise
emissions from digital apparatus set out in the Radio Interference Regulations
of the Canadian Department of Communications.
Parts Breakdown
Item | Part No. | Description | QTY |
---|---|---|---|
1 | 176451 (for kit 176452) | HID® Card Reader, Signo™ 40 HID®, 13.56MHz, |
Output: Wiegand. UL BP6568
NOTE: Requires 10-16 VDC power Supply, sold separately.| 1
93934 (for kit 214915)| HID Card Reader, R40 HID® 13.65Mhz Output Wiegand
RS232, UL BP6568| 1
2| N/A| Board, HID Card Reader Interface Board, Wiegand to RS232.| 1
3| 54282| Screw, Machine 6-32NC x 1/2 in Phillips Flat Countersunk Head SST| 4
4| 58061| Standoff, Female-Female 6-32NC x 7/8 in Long 1/4 in Hex Aluminum| 4
5| 14845| Screw, Machine 6-32NC x 3/8 in Phillips Pan Head 18-8 SST| 4
6| 15399| Spacer, Adhesive 1/4 in Snap In| 4
7| 46199| Cable, Communications 24 AWG 4 Conductor with Foil Shield, Gray PVC
Jacket| 1
Remove Old HID Reader (if needed)
- Remove the existing reader from the kiosk panel.
- Remove the screw from the bottom of the HID Reader.
- Pull the back plate from the HID Reader.
Mount the New Mounting Plate
- Align the new back plate with the existing holes. If necessary, adjust or create new holes for mounting.
- Attach the back plate to the kiosk panel, using the four countersunk screws included in the kit.
CAUTION: If mounting on or near metal, use spacers for optimal read performance.
Use supplied screws to ensure the correct fitting and to avoid damaging the reader or mounting plate.
Secure The Reader To The Mounting Plate
-
Attach the top of the reader on the top of the mounting plate.
-
Align the bottom of the reader with the bottom of the mounting plate.
-
Secure the reader to the mounting plate using the supplied 0.138-32 x 0.375 in screw.
-
Determine a location inside the Kiosk for the HID Reader Interface Card. Perform one of the following:
A. If hole patterns match, install the interface card on the inside of the kiosk panel using existing hardware.
Secure with the standoffs and pan head screws included in the kit.
B. If locating the interface card elsewhere on the panel, securely mount adhesive spacers to the panel and then attach the Card to the adhesive spacers.
Wiring
Kit 176452 Wiring
- Wire connections per Table 5.
IMPORTANT: Kit 176452 requires a 10-16 VDC power supply, sold separately.
Ensure the power supply is reverse voltage protected.
NOTE: Use cable (46199) for wire pairs. Cut cable to length.
Apply heats rink to wire casing ends.
Terminal No. | Description |
---|---|
1 | +12 VDC |
2 | Ground |
3 | Data 1/ Clock / RS-485-A |
4 | Data 0/ Clock / RS-485-A |
5 | LED Input (GRN) |
6 | Beeper Input |
7 | Hold Input/LED Input (Blue) |
8 | LED Input (Red) |
9 | Tamper 2 (RLY2) |
10 | Tamper 1 (RLY1) |
Kit 214915 Wiring
- Wire connections per Table 5.
NOTE: Use cable (46199) for wire pairs. Cut cable to length.
Apply heats rink to wire casing ends.
Terminal No. | Description |
---|---|
1 | Hold Input |
2 | LED Input (Red) |
3 | Shield (SHLD) |
4 | +5 VDC |
5 | Ground (RTN) |
6 | LED Input (GRN) |
7 | Beeper Input |
8 | GPIO4 |
9 | GPIO3 |
10 | Data 0/ Clock / RS-485-A |
11 | Data 1/ Clock / RS-485-A |
12 | OC/Tamper |
13 | GPIO2 |
14 | GPIO1 |
CAUTION: Wiring the reader incorrectly may cause permanent damage.
Test Reader
- Power on the reader. The reader beeps and the LED flashes.
- Test the reader with a credential card. The reader beeps and the LED flashes.
Specifications
Typical Maximum Read Range*:*
2.5 to 4.5 in (6.3 to 11.4 cm) with HID iCLASS® card
1.0 in (2.5 cm) with HID iCLASS key
1.0 in (2.5 cm) with HID iCLASS tag
1.5 to 2.0 in (3.8 to 5.0 cm) with HID iCLASS prox
1 to 2 in (2.5 to 5.0 cm) with MIFARE® card (serial number only)
Using ISO 15693 mode (except MIFARE®). Dependent upon installation conditions. Please note that all iCLASS credentials are available in either a 2K bits (256 Bytes) or 16Kbits (2 KBytes) configuration.
Dimensions: (L × W × H) 3.30 × 0.85 × 4.80 in (84 × 22 × 122 mm)
Material : UL94 polycarbonate
Power Supply: 10 to 16VDC reverse voltage protected Linear supply
recommended
Current Requirements (Avg/Peak): 80/260mA at 12VDC
Operating Temperature: -31°F to 150°F (-35°C to 65°C)
Operating Humidity: 5 to 95% relative humidity non-condensing
Weight: 8.8 oz (249.5 g)
Transmit Frequency: 13.56 MHz
Cable Distance:
Wiegand interface: 500 ft (150 m)
Recommended cable is ALPHA 1295 (22AWG)
Five-conductor stranded with overall shield or equivalent. Additional
conductors may be required to connect all outputs.
Pending Certifications: Taiwan, Singapore, Germany VdS
Approvals:**
UL 294/cUL
FCC Certification
Canada Certification
CE Mark (Europe)
New Zealand
Australia c-Tick
CUSTOMER SUPPORT
© Rice Lake Weighing Systems
Content subject to change without notice.
230 W. Coleman St. • Rice Lake, WI 54868 • USA
USA: 800-472-6703 • International:
+1-715-234-9171
March 19, 2024
www.ricelake.com
PN 178027 Rev C
References
- Rice Lake Weighing Systems
- Manuals | Rice Lake Weighing Systems
- Warranties
- Rice Lake Weighing Systems
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>