Step 1: Make the Ceiling Cutout
Note: Confirm the dimensions needed for your installation based on the Cutout Dimensions section in the manual. Ensure there are no obstructions in the ceiling. -
Step 2: Install the Goofring
Take the goofring with the inner diameter side facing down and pass it over the luminaire. Bend the trims before passing the goofring through. -
Step 3: Position the Luminaire and Goofring
Ensure that the luminaire and goofring faces are correctly aligned. -
Step 4: Attach the Driver Box
Pass the driver box through the ceiling hole and retain the cord to attach it to the luminaire.
FAQ
-
Q: Can this product be installed in residential areas?
- A: This product is designed for commercial environments. Installing it in a residential area may cause harmful interference to radio communications.
-
Q: What are the standard cutout dimensions for the different sizes?
- A: The standard cutout dimensions are as follows:
- 4in Round : 4.87” (123.698mm) up to 5.75” (146.05 mm)
- 6in Round: 6.37” (161.798mm) up to 7.25” (184.15 mm)
- 8in Round: 8.37” (212.598mm) up to 9.25” (234.95 mm)
Downlighting
IS M_GRW 442296472141
ModuLyte 4in, 6in & 8in
CAUTION: THE INSTALLATION AND SERVICING OF THIS PRODUCT MUST BE PERFORMED BY A QUALIFIED ELECTRICIAN OR SERVICE PERSONNEL
NOTE: This equipment has been tested and found to comply with the limits for a Class A digital service, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, many cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
CAN ICES-005 (A) / NMB-005 (A)
Read and understand these instructions before installing luminaire
(fixture)
This luminaire is intended for installation in accordance with the National
Electrical Code and local regulations. To assure full compliance with local
codes and regulations, check with your local electrical inspector before
installation.
WARNING – To prevent electrical shock, turn off electricity at fuse box before proceeding. Allow fixture to cool before handling.
Retain these instructions for maintenance reference
ModuLyte accepts Light Engines:
M4RDL, M6RDL & M8RDL
Caution (RISK OF FIRE)
Use only with ModuLyte LED light engines and reflector.
WARNING – Make sure that the power supply is disconnected before installation.
Cutout Dimensions
-
4in
Round: Standard cutout 4.87’’ (123.698mm) up to 5.75” (146.05 mm) -
6in
Round: Standard cutout 6.37” (161.798mm) up to 7.25” (184.15 mm) -
8in
Round: Standard cutout 8.37” (212.598mm) up to 9.25” (234.95 mm)
Parts
Step 1
Make the ceiling cutout.
Note: Confirm the dimensions needed for your installation in the “Cutout
Dimensions” section on page 1 and ensure that there is nothing in the ceiling
to obstruct the installation (Figure 1).
Step 3
Be sure to settle the luminaire and goofring faces correctly (Figure 3).
Step 5
Insert the luminaire and goofring to the ceiling. Bend the springs of the
luminaire and insert it on the ceiling hole (Figure 5).
WARNING – Watch out for falling parts and make sure the springs open back
to position once the luminaire is inserted to prevent any risk of injury.
Step 2
Take the goofring, with the inner diameter side facing down, and pass it over
the luminaire (Figure 2).
Note: Bend the trims before the goofring is passing through.
Step 4
Pass the driver box through the ceiling hole and retain the cord to attach to
luminaire (Figure 4).
© 2024 Signify Holding. All rights reserved. The information provided herein is subject to change, without notice. Signify does not give any representation or warranty as to the accuracy or completeness of the information included herein and shall not be liable for any action in reliance thereon. The information presented in this document is not intended as any commercial offer and does not form part of any quotation or contract, unless otherwise agreed by Signify.
- Signify North America Corporation
- 400 Crossing Bivd, Suite 600
- Bridgewater, NJ 08807
- Telephone: 800-555-0050
- Signify Canada Ltd.
- 281 Hillmount Road,
- Markham, ON, Canada L6C 253
- Telephone: 800-668-9008
All trademarks are owned by Signify Holding or their respective owners.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>