MEAN WELL PWM-60-KN Series 60W Constant Voltage PWM Output KNX LED Driver Owner’s Manual
- July 30, 2024
- MEAN WELL
Table of Contents
- PWM-60-KN Series 60W Constant Voltage PWM Output KNX LED Driver
- Specifications
- Product Usage Instructions
- Installation
- Dimming Setup
- Troubleshooting
- Q: Can I use this LED driver with dimmable LED fixtures?
- Q: How can I change the PWM frequency?
- Q: What is the maximum number of LED drivers that can be
PWM-60-KN Series 60W Constant Voltage PWM Output KNX LED Driver
Specifications
-
Model: PWM-60-12, PWM-60-24
-
DC Voltage: 12V, 24V
-
Rated Current: 5A, 2.5A
-
Rated Power: 60W
-
Output Dimming Range: 0 – 100%
-
PWM Frequency (Typ.): 200 – 4000Hz (user
changeable via ETS) -
Setup, Rise Time: 500ms, 80ms / 115VAC or
230VAC -
Hold Up Time (Typ.): 16ms / 115VAC or
230VAC -
Voltage Range: 90 – 305VAC, 127 – 431VDC
-
Frequency Range: 47 – 63Hz
-
Power Factor (Typ.): PF > 0.97 / 115VAC, PF
0.95 / 230VAC, PF > 0.92 / 277VAC @ full load
-
Total Harmonic Distortion: THD < 20%
-
Efficiency (Typ.): 86%
-
AC Current (Typ.): 0.8A / 115VAC, 0.4A /
230VAC, 0.32A / 277VAC -
Inrush Current (Typ.): Cold start 50A
(twidth=350s measured at 50% Ipeak) at 230VAC -
Max. No. of PSUs on 16A Circuit Breaker: 9
units (circuit breaker of type B) / 16 units (circuit breaker of
type C) at 230VAC
Product Usage Instructions
Installation
-
Ensure the power source meets the voltage and frequency
requirements specified in the manual. -
Connect the LED driver to the power source following the wiring
diagram provided. -
Mount the LED driver in a well-ventilated area away from direct
sunlight and moisture.
Dimming Setup
To adjust the dimming range, follow these steps:
-
Access the dimming settings through the ETS interface.
-
Select the desired dimming percentage within the range of 0 to
100%. -
Verify the dimming operation by testing the connected LED
fixtures.
Troubleshooting
If you encounter any issues with the LED driver, refer to the
troubleshooting section of the manual or contact customer support
for assistance.
FAQ
Q: Can I use this LED driver with dimmable LED fixtures?
A: Yes, the PWM-60-KN series LED driver supports dimmable LED
fixtures within the specified dimming range.
Q: How can I change the PWM frequency?
A: The PWM frequency can be adjusted via the ETS interface as
per the user manual instructions provided.
Q: What is the maximum number of LED drivers that can be
connected to a 16A circuit breaker?
A: The maximum number of LED drivers depends on the type of
circuit breaker used. Please refer to the manual for specific
details.
P W M – 6 0 – K N 60W Constant Voltage PWM Output KNX LED Driver
series
User’s Manual
– ()
File Name:PWM-60-KN-SPEC 2024-03-12
60W PWM Output KNX LED Driver
PWM-60-KN series
SPECIFICATION
MODEL
PWM-60-12
PWM-60-24
DC VOLTAGE
12V
24V
RATED CURRENT
5A
2.5A
RATED POWER
60W
60W
OUTPUT DIMMING RANGE
0 ~ 100%
PWM FREQUENCY (Typ.) 200~4000Hz user changable via ETS
SETUP, RISE TIME Note.2 500ms, 80ms/ 115AC or 230VAC
HOLD UP TIME (Typ.)
16ms/115VAC or 230VAC
VOLTAGE RANGE Note.3
90 ~ 305VAC 127 ~ 431VDC (Please refer to “STATIC CHARACTERISTIC” section)
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR (Typ.)
PF>0.97/115VAC, PF>0.95/230VAC, PF>0.92/277VAC @ full load (Please refer to “POWER FACTOR (PF) CHARACTERISTIC” section)
TOTAL HARMONIC DISTORTION
THD< 20%(@load60%/115VAC, 230VAC; @load75%/277VAC) (Please refer to “TOTAL HARMONIC DISTORTION” section)
INPUT
EFFICIENCY (Typ.) AC CURRENT (Typ.) INRUSH CURRENT (Typ.)
86%
89%
0.8A / 115VAC 0.4A / 230VAC 0.32A / 277VAC COLD START 50A(twidth=350s measured at 50% Ipeak) at 230VAC; Per NEMA 410
MAX. NO. of PSUs on 16A CIRCUIT BREAKER
9 units (circuit breaker of type B) / 16 units (circuit breaker of type C) at 230VAC
LEAKAGE CURRENT
<0.25mA / 277VAC
<0.5W
OVERLOAD
108 ~ 130% rated output power Hiccup mode, recovers automatically after fault condition is removed
SHORT CIRCUIT
Shut down o/p voltage, re-power on to recover
PROTECTION OVER VOLTAGE
15 ~ 17V Shut down o/p voltage, re-power on to recover
28 ~ 34V
OVER TEMPERATURE Shut down o/p voltage, re-power on to recover
WORKING TEMP.
Tcase=-35 ~ +85 (Please refer to ” OUTPUT LOAD vs TEMPERATURE” section)
MAX. CASE TEMP.
Tcase=+85
WORKING HUMIDITY
20 ~ 95% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY -35 ~ +80, 10 ~ 95% RH
TEMP. COEFFICIENT
±0.03%/ (0 ~ 50)
VIBRATION
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
SAFETY STANDARDS
Note.5
ENEC BS EN/EN61347-1, BS EN/EN61347-2-13, BS EN/EN62384 EAC TP TC 004 approved
independent, GB19510.14,GB19510.1,
KNX STANDARDS
Certified protocol
WITHSTAND VOLTAGE
SAFETY & EMC
ISOLATION RESISTANCE
EMC EMISSION Note.6
I/P-O/P:3.75KVAC
I/P-O/P:100M Ohms / 500VDC / 25/ 70% RH
Compliance to BS EN/EN55015, BS EN/EN61000-3-2 Class C (@load60%) ; BS
EN/EN61000-3-3,GB/T 17743, GB17625.1;EAC TP TC 020
EMC IMMUNITY MTBF
Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11; BS EN/EN61547, light industry
level (surge immunity Line-Line 2KV),EAC TP TC 020
2135.2K hrs min. Telcordia SR-332 (Bellcore) ; 247.7K hrs min. MIL-HDBK-217F
(25)
OTHERS DIMENSION
1505335mm (LWH)
PACKING
0.45Kg;30pcs/16.0Kg/1.0CUFT
NOTE
1. All parameters NOT specially mentioned are measured at 230VAC input, rated
current and 25 of ambient temperature. 2. De-rating may be needed under low
input voltages. Please refer to “STATIC CHARACTERISTIC” sections for details.
3. Length of set up time is measured at first cold start. Turning ON/OFF the
driver may lead to increase of the set up time. 4. The driver is considered as
a component that will be operated in combination with final equipment. Since
EMC performance will be affected
by the complete installation, the final equipment manufacturers must re-
qualify EMC Directive on the complete installation again. (as available on
https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf) 5. This series
meets the typical life expectancy of >50,000 hours of operation when Tcase,
particularly tc point (or TMP, per DLC), is about 75 or less. 6. Please refer
to the warranty statement on MEAN WELL’s website at http://www.meanwell.com 7.
The ambient temperature derating of 3.5/1000m with fanless models and of
5/1000m with fan models for operating altitude higher than 2000m(6500ft). 8.
For any application note and IP water proof function installation caution,
please refer our user manual before using.
https://www.meanwell.com/Upload/PDF/LED_EN.pdf
Product Liability DisclaimerFor detailed information, please refer to
https://www.meanwell.com/serviceDisclaimer.aspx
File Name:PWM-60-KN-SPEC 2024-03-12
60W PWM Output KNX LED Driver
DIMMING OPERATION
PWM-60-KN series
AC/L(Brown) AC/N(Blue)
PWM-60-KN
Dimming principle for PWM style output Dimming is achieved by varying the duty
cycle of the output current.
Output DC current ON
Io=0A
OFF TON
T
TON Duty cycle(%) =
×100%
T
Output PWM frequency up to 4KHz
Vo+(Red) Vo-(Black) KNX+(Red) KNX-(Black)
KNXInterface Apply KNX signal between KNX+ and KNX-. The application program(database) can be downloaded via Online Catalogs from ETS or via http://www.meanwell.com/productCatalog.aspx
File Name:PWM-60-KN-SPEC 2024-03-12
60W PWM Output KNX LED Driver
OUTPUT LOAD vs TEMPERATURE
PWM-60-KN series
LOAD (%)
THD LOAD (%)
100
80 230VAC Input only
60 50 40
20
-35 -25 -10
0
15
30
50
60
AMBIENT TEMPERATURE,Ta ()
70 (HORIZONTAL)
LOAD (%)
100
80 230VAC Input only
60
40
20
-35 -25 0
20
45
60
70
80
85 (HORIZONTAL)
Tcase ()
STATIC CHARACTERISTIC
100 90 80 70 60 50 40
90 100 125 135 145 155 165 175 180 200 230 305
INPUT VOLTAGE (V) 60Hz De-rating is needed under low input voltage.
TOTAL HARMONIC DISTORTION (THD)
24V Model, Tcase at 75
25
20
15
10
5
0
50%
60%
70%
80%
90%
LOAD
115VAC 230VAC 277VAC
100%
EFFICIENCY(%)
PF
POWER FACTOR (PF) CHARACTERISTIC
Tcase at 75
1 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1
0 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
LOAD
115V 230V 277V
EFFICIENCY vs LOAD
PWM-60-KN series possess superior working efficiency that up to 89% can be reached in field applications. 24V Model, Tcase at 75
95
90
85
80
75
115V
70
230V
65
277V
60
55
50 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
LOAD
File Name:PWM-60-KN-SPEC 2024-03-12
60W PWM Output KNX LED Driver
LIFE TIME
PWM-60-KN series
LIFETIME(Kh)
120
100
80
60
40
20
0
25
35
45
55
65
75
85
Tcase( )
File Name:PWM-60-KN-SPEC 2024-03-12
60W PWM Output KNX LED Driver
PWM-60-KN series
Block Diagram
EMI FILTER
I/P
&
RECTIFIERS
PFC fosc : 50~120KHz PWM fosc : 60~130KHz
PFC CIRCUIT
POWER SWITCHING
O.T.P.
O.L.P.
PWM & PFC CONTROL
RECTIFIERS &
FILTER
O.L.P.
DIMMING CIRCUIT
DETECTION CIRCUIT
O.V.P.
Vo+ VoKNX+ KNX-
Note: PWM fosc here is not related to ouput PWM dimming
Mechanical Specification
Case No. PWM-60KN Unit:mm
AC/L(Brown) AC/N(Blue)
300±20
150 KNX programming button & LED 5
SJTW 18AWG×2C
4.5
tc 35
5
tc : Max. Case Temperature
KNX connector is included in the box
300±10 Ul2464 18AWG×2C(Vo+,Vo-)
Ul2464 20AWG×2C(KNX+,KNX-) 350±10
Vo+(Red) Vo-(Black) KNX+(Red) KNX-(Black)
5 53
13 5
35
Mechanical view of by request
AC/L(Brown) AC/N(Blue)
Vo+(Red) Vo-(Black) KNX+(Red) KNX-(Black)
File Name:PWM-60-KN-SPEC 2024-03-12
60W PWM Output KNX LED Driver
Recommend Mounting Direction
PWM-60-KN series
Installation Manual Connection for KNX-type
AC/L(BROWN) AC/N(BLUE)
Vo+(RED)
–
Vo-(BLACK)
KNX+(RED)
LED strip or constant voltage LED bulb
KNX-(BLACK) PWM KN series can be ETS adressing/programming WITHOUT connecting to AC mains
KNX Bus
Cautions Before commencing any installation or maintenance work, please
disconnect the power supply from the utility. Ensure
that it cannot be re-connected inadvertently! Keep proper ventilation around
the unit and do not stack any object on it. Also a 10-15 cm clearance must be
kept when
the adjacent device is a heat source. Mounting orientations other than
standard orientation or operate under high ambient temperature may increase
the
internal component temperature and will require a de-rating in output current.
Current rating of an approved primary /secondary cable should be greater than
or equal to that of the unit. Please refer
to its specification. Tc max. is identified on the product label. Please make
sure that temperature of Tc point will not exceed limit. DO NOT connect “KNX-
to Vo-“. The power supply is considered as a component that will be operated
in combination with final equipment. Since EMC
performance will be affected by the complete installation, the final equipment
manufacturers must re-qualify EMC Directive on the complete installation
again.
File Name:PWM-60-KN-SPEC 2024-03-12
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>