Specifications:

  • Model: AFL-4032
  • Power Supply: Transformer rated maximum of 300 watts (25 AMPS) at 15 volts
  • Installation: For outdoor use
  • Wire Connector: UL listed wire connectors suitable for outdoor use
  • Low Voltage Cable: Intended for shallow burial (less than 6 inches/152 mm)

Product Usage Instructions

Installation:
IMPORTANT SAFETY INSTRUCTIONS:

  • Ensure power is turned OFF before installation.
  • Install luminaire at least 10 feet from pool, spa, or fountain.
  • Use a power supply (transformer) rated maximum of 300 watts at 15 volts.
  • Use UL listed wire connectors suitable for outdoor use for wiring connections.
  • Position low voltage wire and wire connector within 6 inches from a building structure or luminaire.
  • Main low voltage cable is intended for shallow burial (<6 inches).

Maintenance:
IMPORTANT SAFETY INSTRUCTIONS:

  • Turn off/unplug and allow to cool before replacing lamp.
  • Avoid touching the hot lamp, lens, guard, or enclosure.
  • Keep lamp away from materials that may burn.
  • Use a soft cloth if touching the lamp to prevent damage from skin oil.
  • Do not operate the luminaire with a missing or damaged shield.

Installation Steps:

  • Install Fixture Body to Stake:
    Pass the supply wires through the wireway slot on the stake and thread the fixture body onto the stake.

  • Install Stake into Soil:
    Insert the stake into the soil until the flange is flush to the ground.

  • Wire Connections:
    Strip both leads from the luminaire pigtail and connect them to the main supply cable leads using UL listed wire connectors.

  • Adjust Luminaire Direction:
    Loosen the screw at the knuckle using the Allen wrench, adjust the luminaire direction, and tighten the screw once in desired position.

Frequently Asked Questions (FAQ):

  • Q: Can this luminaire be used near water bodies?
    A: No, the luminaire should be installed at least 10 feet away from pools, spas, or fountains for safety reasons.

  • Q: What type of wire connectors should be used for wiring connections?
    A: UL listed wire connectors suitable for outdoor use should be used for wiring connections as specified in the instructions.

IMPORTANT SAFETY INSTRUCTIONS

This luminaire is intended for installation in accordance with local codes and the National Electric Code (NEC). Failure to adhere to these codes and instructions may result in serious injury, property damage and void the warranty.

These instructions do not intend to cover all variations in installation, operation maintenance or mounting situations.

  1. Make sure the power is turned OFF before installing or servicing this luminaire.
  2. WARNING: risk of electrical shock. Install all luminaires 10 feet (3.05M) or more from pool, spa or fountain.
  3. This luminaire is intended to be used only with a power supply (transformer) rated maximum of 300 watts (25 AMPS) at 15 volts.
  4. Wiring connections must be made with UL listed wire connectors that are suitable for outdoor use.
  5. Position the low voltage wire and wire connector so that it is located within 6 inches (15.2 cm) from a building structure, a luminaire or fitting.
  6. The main low voltage cable is intended for shallow burial – less than 6 inches (152 mm).

INSTRUCTIONS PERTAINING TO A RISK OF FIRE, OR INJURY TO PERSONS

LIGHTED LAMP IS HOT!

WARNING – To reduce the risk of FIRE OR INJURY TO PERSONS.

  1. Turn off/unplug and allow to cool before replacing lamp.
  2. Lamp gets HOT quickly! Contact only switch/plug when turning on.
  3. Do not touch the hot lens, guard or enclosure.
  4. Keep lamp away from materials that may burn.
  5. Do not touch lamp at any time. Use a soft cloth. Oil from skin may damage lamp.
  6. Do not operate the luminaire fitting with a missing or damaged shield.

PACKAGE CONTENTS

  • A. (1) Fixture Body
  • B. (1) Allen Wrench
  • C. (1) Stake

PRODUCT DIMENSIONS

INSTALLATION

INSTALL FIXTURE BODY TO STAKE

  • Pass the supply wires of the fixture body through the wireway slot on the stake. Thread the fixture body onto  the stake.

INSTALL STAKE INTO SOIL

  • Insert the stake into the soil until flange of stake is flush to the ground.

WIRE CONNECTIONS

  • Strip both leads from luminaire pigtail. Using two UL listed wire connectors (sold separately), connect the leads from the luminaire to main supply cable leads.

ADJUST LUMINAIRE DIRECTION

  • By using the Allen wrench, loosen the screw at the knuckle and adjust the luminaire to the desired direction. Once the desired direction is achieved, tighten the screw.