esera MSP 120 1-Wire Multisensor User Guide

June 12, 2024
esera

Art. Nr. 11165
Quick Guide

MSP 120

esera MSP 120 1-Wire Multisensor

1-Wire Multisensor Pro II (flush mounted)
for temperature, humidity and air quality (VOC)

MSP 120 1-Wire Multisensor

  • Professional flush mounted Multisensor for temperature, humidity air quality (VOC)
  • For commercial and residential applications, smart building, smart home, schools, public buildings and companies
  • Highly accurate sensors with 12Bit resolution
  • Air quality sensor (VOC) with short warm-up time and high resolution at low power consumption
  • Universal flush wall mounting
  • Shapely and high quality sensor housing
  • Simple 5VDC power supply

Introduction

Thank you for choosing a device from ESERA.
With the ESERA 1-Wire Multisensor Pro II, you have purchased a professional and highly accurate Multisensor.

Note
The module may only be operated at the voltages and ambient conditions provided for it. The operating position of the device is arbitrary.
The modules may only be put into operation by a qualified electrician.
For further information on the operating conditions, see the following instructions under “Operating conditions” in the User Guide.

All rights reserved. Reproduction as well as electronic duplication of this user guide, complete or in part, requires the written consent of ESERA GmbH. Subject to technical changes.ESERA GmbH 2022.

Note
Before you start assembling the device and putting the product into operation, please read this Quick Guide carefully until the end, especially the section on safety instructions.
Please download the complete User Guide in PDF format from our website.
In the detailed User Guide you will find further information about the device, installation, function and operation.
The User Guide, connection diagram and application examples can be found at https://download.esera.de/pdflist
If you have problems with downloading the documents, please contact our support by mail at [email protected]
We are very careful to act in an environmentally friendly and resource-saving way for you. That is why we use paper and cardboard instead of plastics wherever possible.
We would also like to make a contribution to the environment with this Quick Guide.

Assembly

The mounting location must be protected from direct moisture (e.g. dripping water) and drafts. The device may only be used in dry indoor rooms and in protected outdoor areas. The device is intended for mounting as a stationary device.

Disposal note

**** Do not dispose of the unit in household waste! Electronic devices must be disposed of at the local collection points for electronic devices in accordance with the Directive on
Waste Electrical and Electronic Equipment!

Safety instructions

When handling products that come into contact with electrical voltage, the applicable VDE regulations must be observed, in particular VDE 0100, VDE 0550/0551, VDE 0700, VDE 0711 and VDE 0860.

  • All final or wiring work must be carried out with the power turned off.
  • Before opening the device, always unplug or make sure that the unit is disconnected from the mains.
  • Components, modules or devices may only be put into service if they are mounted in a contact proof housing. During installation they must not have power applied.
  • Tools may only be used on devices, components or assemblies when it is certain that the devices are disconnected from the power supply and electrical charges stored in the components inside the device have been discharged.
  • Live cables or wires to which the device or an assembly is connected, must always be tested for insulation faults or breaks.
  • If an error is detected in the supply line, the device must be immediately taken out of operation until the faulty cable has been replaced.
  • When using components or modules it is absolutely necessary to comply with the requirements set out in the accompanying description specifications for electrical quantities.
  • If the available description is not clear to the non-commercial end-user what the applicable electrical characteristics for a part or assembly are, how to connect an external circuit, which external components or additional devices can be connected or which values these external components may have, a qualified electrician must be consulted.
  • It must be examined generally before the commissioning of a device, whether this device or module is basically suitable for the application in which it is to be used.
  • In case of doubt, consultation with experts or the manufacturer of the components used is absolutely necessary.
  • For operational and connection errors outside of our control, we assume no liability of any kind for any resulting damage.
  • Kits should be returned without their housing when not functional with an exact error description and the accompanying instructions. Without an error description it is not possible to repair. For time-consuming assembly or disassembly of cases charges will be invoiced.
  • During installation and handling of components which later have mains potential on their parts, the relevant VDE regulations must be observed.
  • Devices that are to be operated at a voltage greater than 35 VDC / 12mA, may only be connected by a qualified electrician and put into operation.
  • Commissioning may only be realized if the circuit is built into a contact proof housing.
  • If measurements with an open housing are unavoidable, for safety reasons an isolating transformer must be installed upstream or a suitable power supply can be used.
  • After installing the required tests according to DGUV / regulation 3 (German statutory accident insurance, https://en.wikipedia.org/wiki/German_Statutory_Accident_Insurance) must be carried out.

All rights reserved. Reproduction as well as electronic duplication of this user guide, complete or in part, requires the written consent of ESERA GmbH. Subject to technical changes.© ESERA GmbH 2022.

Warranty

ESERA GmbH guarantees that the goods sold at the time of transfer of risk to be free from material and workmanship defects and have the contractually assured characteristics. The statutory warranty period of two years begins from date of invoice. The warranty does not extend to the normal operational wear and normal wear and tear. Customer claims for damages, for example, for non-performance, fault in contracting, breach of secondary contractual obligations, consequential damages, damages resulting from unauthorized usage and other legal grounds are excluded. Excepting to this, ESERA GmbH accepts liability for the absence of a guaranteed quality resulting from intent or gross negligence. Claims made under the Product Liability Act are not affected.
If defects occur for which ESERA GmbH is responsible, and in the case of replacement goods, the replacement is faulty, the buyer has the right to have the original purchase price refunded or a reduction of the purchase price. ESERA GmbH accepts liability neither for the constant and uninterrupted availability of the ESERA GmbH or for technical or electronic errors in the online offer.
We develop our products further and we reserve the right to make changes and improvements to any of the products described in this documentation without prior notice. If you need documentation or information about older product versions, contact us by email at [email protected].

Trademarks

All mentioned designations, logos, names and trademarks (including those which are not explicitly marked) are trademarks, registered trademarks or other copyright or trademarks or titles or legally protected designations of their respective owners and are hereby expressly recognized as such by us. The mention of these designations, logos, names and trademarks is made for identification purposes only and does not represent a claim of any kind on the part of ESERA GmbH on these designations, logos, names and trademarks. Moreover, from their appearance on ESERA GmbH webpages it cannot be concluded that designations, logos, names and trademarks are free of commercial property rights.
ESERA and Auto-E-Connect are registered trademarks of ESERA GmbH.
Auto-E-Connect is registered by ESERA GmbH as a German and European Patent.
ESERA GmbH is a supporter of the free internet, free knowledge and the free encyclopedia Wikipedia.
We are a member of Wikimedia Deutschland e.V., the provider of the German site Wikipedia (https://de.wikipedia.org). ESERA membership number: 1477145
Wikimedia Germany’s association purpose is the promotion of free knowledge.
Wikipedia® is a registered trademark of the Wikimedia Foundation Inc.

Contact

ESERA GmbH
Adelindastrasse 20,
D-87600 Kaufbeuren, Deutschland / Germany
Tel.: +49 8341 999 80-0, Fax: +49 8341 999 80-10 WEEE-Nummer: DE30249510
www.esera.de [email protected]
Alle Rechte vorbehalten. Nachdruck, auch auszugsweise, ohne ausdrückliche Zustimmung von ESERA GmbH nicht erlaubt.
Technische Änderungen vorbehalten. © ESERA GmbH 2022. All rights reserved. Reproduction as well as electronic duplication of this user guide, complete or in part, requires the written consent of ESERA GmbH. Subject to technical changes. © ESERA GmbH 2022.

www.esera.de
11165 V1.0 R1.0 Quick Guide

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

esera User Manuals

Related Manuals