AMP Lighting BDL-ASI-9010-50-BK AMP Low Voltage Landscape Lighting User Guide

October 30, 2023
AMP Lighting

AMP Lighting BDL-ASI-9010-50-BK AMP Low Voltage Landscape Lighting

Product Information

The BDL-ASI-9009-25-BK and BDL-ASI-9010-50-BK are string lights designed for outdoor use. The lights come with 25 or 50 bulbs, depending on the variant, and have a maximum rating of 125W (1.04A). The string lights can be connected end-to-end with other lighting strings or decorative outfits up to a maximum of 432W (3.6A) total. The light sockets must be installed base up so that  are facing downward only. The product is not intended for installation in ceilings, soffits, cabinets, or other enclosed spaces. The lights should be kept at least 16 feet away from pools and spas, and all lamps should hang freely in a downward direction with a minimum of 3 spaces from the nearest object.

Installation & Maintenance Guide

  1. Make sure that the power is turned OFF before installing or replacing fuses and/or lamps.
  2. Do not overload the string lights. Connect other lighting strings or decorative outfits end to end up to a maximum of 432W (3.6A) total.
  3. Use only two-wire outdoor extension cords that have two-prong grounding plugs and grounding receptacles that accept the two-prong plugs. Do not alter the plug.
  4. Light sockets must be installed base up so that bulbs are facing downward ONLY.
  5. Keep combustible material clear of bulbs. Do NOT allow lamps or sockets to come into contact with walls, fabrics associated with shades, blinds, or other materials.
  6. Do not cluster the bulbs.
  7. Not intended for installation in ceilings, soffits, cabinets, or other enclosed spaces.
  8. Avoid making connections or disconnections when the equipment is wet. Do not use with an extension cord near or where water may accumulate. Do not submerge. Keep lamps at least 16 feet from pools and spas. Keep receptacles dry.
  9. For temporary (90 days max) installation and use only.

Safety Instructions

  1. Disconnect power at source prior to re-lamping String Lights.
  2. For outdoor String Lights, do NOT re-lamp light strings during rain or when wet.
  3. Re-lamp String Lights only during dry and calm weather conditions.
  4. Do NOT secure light strings to buildings or other structural supports using nails, staples, or other sharp, conducting materials. DO NOT DAMAGE THE WIRE.
  5. Do NOT pierce or otherwise compromise wires or socket’s outer covering, jacket, or sheathing.
  6. Periodically inspect wire and sockets for degradation due to weather, UV light, or other damage. Promptly replace worn-out light string.

Installation Methods

Method 1: Using a Guide Wire
Attach the guide wire to a structural support and then pass the guide wire through the holes on the top end of the sockets. Fix the guide wire to your desired location or tie the bistro string to applicable locations directly.

Method 2: Attach to a Structure
Attach the string lights to a structural support using screw hooks. The lights should be attached to a structural support at least every 24 feet.

Package Contents

  • (1) String (25 feet or 50 feet)
  • (1) Set of Lamps (25 or 50 pieces)

INSTALLATION & MAINTENANCE GUIDE

AMP® Low Voltage Landscape Lighting
AMP® 120V E12 Bistro Lights
BDL-ASI-9009-25-BK and BDL-ASI-9010-50-BK

Help Hotline:
1-813-978-3900 • Mon-Fri 9am-6pm (EST)

Important: Please Read Before Installation
This fixture is intended for installation in accordance with local codes and the National Electric Code (NEC). Failure to adhere to these codes and instructions may result in serious injury, property damage and void the warranty.
These instructions do not intend to cover all variations in installation,operation maintenance or mounting situations.

  1. Make sure that the power is turned OFF before installing or replacing fuses and/or lamps.
  2. This light string is rated 125W (1.04A), do not overload. Connect other lighting strings or decorative outfits end to end up to a maximum of 432W (3.6A) total.
  3. Use only two wire outdoor extension cords that have two-prong grounding plugs and grounding receptacles that accept the two prong plugs. Do not altwer the plug.
  4. Light sockets must be installed base up so that bulbs are facing downward ONLY.
  5. Keep combustible material clear of bulbs. Do NOT allow lamps or sockets to come into contact with walls, fabrics associated with shades, blinds or other materials. Lamps should hang freely in a downward direction with a minimum of 3” space from the nearest object.
  6. Do not cluster the bulbs.
  7. Not intended for installation in ceilings, soffits, cabinets or other enclosed spaces.
  8. Avoid making connections or disconnections when the equipment is wet. Do not use with extension cord near or where water may accumulate. Do not submerse. Keep lamps at least 16 feet from pools and spas. Keep receptacles dry.
  9. For temporary (90 days max) installation and use only.

Safety Instructions

WARNING – TO REDUCE THE RISK OF FIRE OR INJURY TO PERSONS.

  1. Disconnect power at source prior to re-lamping String Lights.
  2. For outdoor String Lights, do NOT re-lamp light strings during rain or when wet.
  3. Re-lamp String Lights only during dry and calm weather conditions.
  4. Do NOT secure light strings to buildings or other structural supports using nails, staples or other sharp, conducting materials. DO NOT DAMAGE THE WIRE.
  5. Do NOT pierce or otherwise compromise wires or socket’s outer covering, jacket or sheathing.
  6. Perodically inspect wire and sockets for degradation due to weather, UV light or other damage. Promptly replace worn out light string.

Package Contents

  • A. (1) String (25 feet or 50 feet)
  • B. (1) Set of Lamps (25 or 50 pieces)

Product Dimensions

AMP-Lighting BDL-ASI-9010-50-BK-AMP-Low-Voltage-
Landscape-Lighting-FIG-1Installation Method

Using a Guide WireAMP-Lighting BDL-ASI-9010-50-BK-AMP-Low-Voltage-
Landscape-Lighting-FIG-2 Pass the guide wire through the holes on the top end of the sockets and then fix the guide wire to your desired location or tie the bistro string to applicable locations directly

Attach to a StructureAMP-Lighting BDL-ASI-9010-50-BK-AMP-Low-Voltage-
Landscape-Lighting-FIG-3

Multiple Strings Connection

(Optional)
It is easy to connect multiple strings. Refer to wattage information below. ****The MAXIMUM wattage per bulb is 5 watts.
DO NOT EXCEED 432 watts with all sets combined

Install Lamps

Tighten the UL Classified bulbs (5 watt Max Candelabra-base) into the socket clockwise until the top of the socket forms a tight seal around the bulb and the bulb makes solid contact with the socket.

Insert the plug of the first string into the wall outlet to complete the installation.

 customersupport@amplighting.com • 813.978.3900
www.ampliehtine.com

Help Hotline:
1-813-978-3900 • Mon-Fri 9am-6pm (EST)

Specifications and product details subject to change without notice.
© Copyright 2022, AMP® Lighting, Lutz FL USA 33549 • All rights reserved.
customersupport@amplighting.com • 813.978.3900