Comelit 4681 Audio video Module For 2 Wire System Instructions
- July 26, 2024
- Comelit
Table of Contents
- Comelit 4681 Audio video Module For 2 Wire System
- Installation Instructions
- Description
- Technical specifications
- External unit installation
- Connections
- Module connection
- Vandalcom modules
- Modules for Single-plate external unit
- Simple key modules
- Button programming
- Special programmes
- System performance and layouts
- FAQ
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Comelit 4681 Audio video Module For 2 Wire System
Specifications
- Product Name : Audio/Video Module for 2-wire system
- Model : Art. 4681 / 1621VC
- Power Supply : 12V, Max 150mA
Product Description
The Art. 4681 is a color audio-video module compatible with Comelit
Building Kit video entry systems (exclusively 2-wire). It is designed for use
in residential, commercial, industrial, and public buildings. The module can
be installed in various Comelit external units and is compatible with the
riser power supply unit Art. 1210. The Art. 1621VC is an audio module for
connecting a remote color PAL camera. It is also compatible with Comelit
Building Kit video entry systems (2 pure wires) and designed for use with the
riser power supply unit Art. 1210. It can be installed in similar external
units as the Art. 4681 and can be expanded with additional modules to meet
system requirements.
Installation Instructions
Warning: Disconnect the power supply before working on any wiring.
All installation activities must be carried out by qualified technical personnel following the instructions provided in the manuals. Use wires with appropriate cross-sections and avoid routing system wires alongside power cables above 230V.
Compatibility Tables
| Ikall| Ikall Metal| Vandalcom| Roma| N Series
---|---|---|---|---|---
Art. 4681| 33410| 33410M| 33411| 33411A| 33411M
Art. 1621VC| 33400| 33400M| 33401| 33401A| 33401M
User Interface Overview
- S1 – DIP switches for function programming and user code setting.
- PR switch – Input/output programming.
- J11 and J9 jumper – Power supply management.
- CNF switch – Special program confirmation.
- Connector for module 1621VC – Remote camera connection.
- Loudspeaker volume control.
Description
Article 4681 is a colour audio-video module which is compatible with Comelit “Building Kit” video entry systems (exclusively 2-wire), exclusively for use in conjunction with riser power supply unit Art. 1210. It can be installed in Ikall, Ikall Metal, Vandalcom, Roma and “N” Series external units and can be finished with additional modules to meet all system requirements.
Item 1621VC is an audio module allowing connection of a remote colour PAL camera. It is compatible with Comelit “Building Kit” video entry systems (2 pure wires), exclusively for use in conjunction with riser power supply unit Art. 1210. It can be installed in Ikall, Ikall Metal, Vandalcom, Roma and “N” Series external units and can be finished with additional modules capable of fulfilling all system requirements.
To make use of the indicator LEDs (busy, call sent, door opened, communication active) faceplates from kit 33400K are available to purchase separately for the IKALL series.
-
S1 DIP switches for function programming and setting the user code.
-
PR switch for input/output programming.
-
J11 and J9 jumper for power supply management. Remove both in the case of a separate power supply.
-
CNF switch for confirming special programmes.
-
The connector is reserved for module 1621VC, for the connection of the remote camera.
-
Loudspeaker volume control.
-
Indicator LED: call sent.
-
Speaker.
-
Microphone.
-
Indicator LED: system busy.
-
Indicator LED : sound activated.
-
Color camera (with Art. 4681 only).
-
Indicator LED: lock-release activated.
-
8-pole cable connector.
-
JP1 RC network management for door lock filter on relay contacts (see “Variant for using the external unit relay/ Variant for using a safety lock”).
-
Terminal block for connection:
- SE+ SE- electric lock connection
- COM common relay contact
- NC normally closed relay contact
- NO normally open relay contact
- GND input reference negative for DO-RTE
- DO door opened signal input
- RTE local lock-release input
- V- power supply negative
- V+ power supply positive
- LL bus line connection
Cables for remote camera connection (Art. 1621VC only)
- Use cable A to power the camera from the external unit (12V-150 mA MAX).
- Use cable B if the camera is powered separately.
Technical specifications
Art. 4681
- MAIN SPECIFICATIONS
- Simplebus Top system No
- Compatible with the Building Kit System Yes
- Vip system No
- Audio system No
- Audio/video system Yes
- Camera Colors
- Video encoding Mpeg
- Type of sensor 1/3” CCD
- Horizontal resolution (TVL) 540TVL
- Minimum illumination 0,35lux
- Lens size 3,6mm
- Camera orientation Yes
- Clamps L L V+ V- RTE DO GND SE- SE+ COM NC NO
- Microphone Yes
- Microphone volume control No
- Loudspeaker Yes
- Loudspeaker volume control Yes
- Relative humidity for operation 25 % – 75 %
Art. 1621VC
- MAIN SPECIFICATIONS
- Simplebus Top system No
- Compatible with the Building Kit System Yes
- Vip system No
- Audio system No
- Audio/video system Yes
- Clamps L L V+ V- RTE DO GND SE- SE+ COM NC NO
- Microphone Yes
- Microphone volume control No
- Loudspeaker Yes
- Loudspeaker volume control Yes
- Relative humidity for operation 25 % – 75 %
External unit installation
The camera must not be installed opposite bright light sources, or in places where the filmed subject is against the light. In dim environments, we recommend additional lighting is provided. Connect the module support frame to earth.
Connections
Module connection
On systems with Art. 4681/1621VC and power supply unit Art. 1210, the maximum current available for the external unit modules is 100 mA. Calculate the total power consumption of the modules in your system configuration using the Consumption table. If the total power consumption exceeds 100 mA, connect a supplementary power supply unit (Art. 1595) to the V+ and V- contacts of the external unit, as shown in the figure below (see “4681, 1621VC connections with separate power supply”). In any case, the total absorption must be lower than 500 mA.
External unit module consumption table
Code | Consumption |
---|
Ikall and Ikall Metal modules
33433 / 33434 / 33436
33433M / 33434M / 33436M
| 20mA
3336 / 3336M| 20mA
3339M| 20mA
3348B
3348BM
| | 30mA
with 1 bistable relay active| 60mA
with 2 bistable relays active| 80mA
3360B
3060BM
| 45mA
3332 / 3332M| 20mA
Vandalcom modules
3262S/1/2 / 3268S/1/2 (con Art. 1172B)| 8 mA
3064S (con Art. 1172B)| 16 mA
3070S| only with 1595
3072S| only with 1595
Modules for Single-plate external unit
3063D| 8mA
1172B LED bulb| 8mA
Simplekey modules
SK9000I| 50mA
SK9001I| 50mA
ACM/R| 60mA
ACM/500-2| 60mA
Ikall / Ikall Metal modules
Connection of button modules 33433, 33434, 33436, 33433M, 33434M, 33436M
Connection of Art. 3348B, 3348BM
Connection of Art. 3360B, 3360BM
Vandalcom modules
Connection of Art. 3064S and Art. 1172B
Connection of Art. 3064S and Art. 1172B with additional power supply
Connection of Art. 3188A
Connection of Art. 3070S, 3072S
Modules for Single-plate external unit
Connection of Art. 3063D
Connection of Art. 3063D with additional power supply
Simple key modules
Connection with Art. SK9015 for connection of readers Art. SK9000I and Art. SK9001I
Button programming
Special programmes
CODE | DIP SWITCHES ON | FUNCTIONS |
---|---|---|
De-misting heating element | ||
213 | 1,3,5,7,8 | OFF (default) |
212 | 3,5,7,8 | ON |
Audio-visual messages | ||
195 | 1,2,7,8 | Hebrew |
196 | 3,7,8 | Polish |
197 | 1,3,7,8 | Catalan |
198 | 2,3,7,8 | Galician |
199 | 1,2,3,7,8 | Basque |
206 | 2,3,4,7,8 | Danish |
207 | 1,2,3,4,7.8 | Norwegian |
211 | 1,2,5,7,8 | Swedish |
215 | 1,2,3,5,7.8 | Italian |
216 | 4,5,7,8 | French |
217 | 1,4,5,7,8 | Spanish |
218 | 2,4,5,7,8 | Dutch |
219 | 1,2,4,5,7.8 | Greek |
220 | 3,4,5,7,8 | English |
221 | 1,3,4,5,7.8 | German |
222 | 2,3,4,5,7.8 | Portuguese |
202 | 2,4,7,8 | Enables voice message (door opened warning) when the RTE |
contact is closed
203| 1,2,4,7,8| Disables voice message (door opened warning) when the
RTE contact is closed (default setting)
210| 2,5,7,8| Visual messages only
214| 2,3,5,7,8| OFF (default)
| |
| | Actuator command management
N.B. Art. 1256 in generic actuator mode must not be present in the system.
227| 1,2,6,7,8| Actuator function on S serial line = enabled
228| 3,6,7,8| Actuator function on S serial line = disabled (default)
| |
229| 1,3,6,7,8| C.NC.NO relay activation on actuator command: 2 sec
230| 2,3,6,7,8| C.NC.NO relay activation on actuator command: 4 sec
231| 1,2,3,6,7.8| C.NC.NO relay activation on actuator command: 8 sec
| |
| | Door lock
245| 1,3,5,6,7.8| Door lock time: 2 sec + disabling tone (default)
| |
246| 2,3,5,6,7.8| Door lock time: 4 sec
247| 1,2,3,5,6,7,8| Door lock time: 8 sec
| |
248| 4,5,6,7,8| Door lock confirmation tone: enabled
251| 1,2,4,5,6,7,8| Relay C.NC.NO in parallel to SE (default)
| |
252| 3,4,5,6,7.8| Lock-release always enabled (default)
253| 1,3,4,5,6,7,8| Lock-release only enabled for user called
| |
| | System functions
232| 4,6,7,8| Awaiting response time: 60 sec (default)
233| 1,4,6,7,8| Awaiting response time: 120 sec
234| 2,4,6,7,8| Awaiting response time: 30 sec
| |
235| 1,2,4,6,7.8| Talk time: 90 sec. (default)
---|---|---
236| 3,4,6,7,8| Talk time: 180 sec
| |
237| 1,3,4,6,7.8| Self-ignition: enabled (default)
238| 2,3,4,6,7.8| Self-ignition: disabled
| |
239| 1,2,3,4,6,7,8| Confirmation tone on user call = enabled (default)
240| 5,6,7,8| Confirmation tone on user call = disabled
| |
243| 1,2,5,6,7.8| Awaiting reset time: 10 sec (default)
244| 3,5,6,7,8| Awaiting reset time: 1 sec
| |
208| 5,7,8| Enables “Reset wait time” on lock-release command (default)
209| 1,5,7,8| Disables “awaiting reset time” on lock-release command
(awaiting response time or talk time will be activated)
| |
249| 1,4,5,6,7.8| Call transmission: single (default)
250| 2,4,5,6,7.8| Call transmission: triple
| |
| | System mode
0| | Simplebus (default)
255| 1,2,3,4,5,6,7.8| Simplebus Top (NO Art. 4681/4)
| |
254| 2,3,4,5,6,7,8| Restore default
Installation information
- The module Art. 4681 / Art. 1621VC operates by default as a main external unit (timed busy signal). To set it as a secondary external unit (busy signal active for the whole time the riser is in use), set all the selector DIP switches to ON.
- When a call is transmitted from the external unit, if a busy tone is heard instead of the ringtone, this means communication with another external unit is in progress.
System performance and layouts
For further information of system performance and to view installation layouts, click on the type of system that best meets your needs:
- Building Kit audio/video system for the creation of audio-video systems for small apartment blocks
Via Don Arrigoni, 5 – 24020 Rovetta (BG) – Italy
Warning
-
Intended use
This Comelit product is designed and manufactured for use in the creation of audio and video communication systems in residential, commercial, industrial and public buildings. -
Installation
All activities connected to the installation of Comelit products must be carried out by qualified technical personnel, with careful observation of the indications provided in the Manuals / Instruction sheets supplied with those products. The product must be installedto the highest standards. -
Wires
- Disconnect the power supply before carrying out any operations on the wiring.
- Use wires with a cross-section suited to the distances involved, observing the instructions provided in the system manual.
- We advise against running the system wires through the same duct as power cables (230V or higher).
-
Safe usage
To ensure Comelit products are used safely:- carefully observe the indications provided in the Manuals / Instruction sheets,
- make sure the system created using Comelit products has not been tampered with / damaged.
-
Maintenance
Comelit products do not require maintenance aside from routine cleaning, which should be carried out in accordance with the indications provided in the Manuals / Instruction sheets. -
Any repairs must be carried out:
- for the products themselves, exclusively by Comelit Group S.p.A.,
- for the systems, by qualified technical personnel.
Do not use alcohol or aggressive products for cleaning purposes.
-
Disclaimer
- Comelit Group S.p.A. does not assume any responsibility for
- any purpose other than the intended use,
- failure to observe the indications and warnings contained in this Manual / Instruction sheet.
- Comelit Group S.p.A. reserves the right to change the information provided in this Manual / Instruction Sheet at any time and without prior notice.
Directives
The manufacturer, Comelit Group S.p.A., hereby declares that this equipment
conforms to the applicable directives. The full EU conformity declaration is
available on the web page for the product. In accordance with art. 26 of
Italian Legislative Decree dated 14th March 2014, no. 49 “Implementation of
directive 2012/19/ EU on Waste Electrical and Electronic Equipment (WEEE)”,
the “crossed-out wheelie bin” symbol indicates that at the end of its useful
life, this product must be separated from other waste before collection for
disposal. The user should therefore take the exhausted appliance to suitable
local collection centres for waste electrical and electronic products. As an
alternative to handling this process yourself, you can take the appliance to
your local equipment dealer when purchasing a new equivalent product.
Electronics dealership businesses covering an area of 400 m² are also obliged
to accept waste electronic products smaller than 25 cm for disposal, without
any obligation to purchase. Suitable separated waste collection for the
subsequent reuse of the appliance sent for recycling, processing and
environmentally conscious disposal helps to avoid potential negative effects
on the environment and human health, and encourages the reuse and recycling of
the materials used in the construction of the appliance.
FAQ
Q: Can I install these modules without professional help?
A: It is recommended to have qualified technical personnel carry out the
installation to ensure proper functioning and safety.
Q: What is the maximum power supply for the modules?
A: The modules require a 12V power supply with a maximum current of 150mA.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>