Specifications

  • Model: CN9850
  • Product Name: 1-Local / Remote Shared Access Single Port 4K HDMI KVM over IP Switch
  • Part Number: PAPE-1223-Z25G
  • Released: 02/2024

FAQs

  • Q: Can I use this switch to control multiple devices simultaneously?
    • A: Yes, the CN9850 allows shared access to multiple devices through its single port with efficient KVM over IP functionality.
  • Q: Is it possible to mount this switch on a rack or wall?
    • A: Yes, the unit can be either placed on a flat surface or mounted onto a rack or wall using the provided mounting kit.

Hardware Overview

Front View

  1. KVM HDMI port
  2. KVM audio ports
  3. CPU COM (RS-232 DTE) port
  4. local console COM (RS-232 DCE) port

Rear View

  1. grounding terminal
  2. power jacks
  3. control terminal

Side View

  1. control port (reserved)

Placement

  • The unit can be placed on a flat surface or mounted onto a rack or a wall.
  • If you plan to have your unit mounted onto a rack or a wall, refer to the Placement section of the user manual.

Installation

ATEN-CN9850-AT-E-HDMI-KVM-Over-IP-Switch-FIG-1 \(4\)

  1. 1 Connect the unit’s grounding terminal to a suitable grounded object.
    • Note: Do not omit this step. Proper grounding helps prevent damage from power surges and static electricity.
  2. Plug your USB keyboard, mouse, and HDMI monitor into the local console ports on the rear of the unit.
  3. Use the KVM cable provided, and connect the unit’s KVM HDMI, USB Type-B, and audio ports to the server / PC for keyboard, mouse, video, and audio signal transmissions.
  4. (Optional) If you wish to access locally using the laptop USB console (LUC) function, use the USB Type-A to Mini-B cable provided to connect a USB port of the laptop to this LUC port. Make sure you have set the mode in the USB IO Setting to LUC. Refer to the user manual for more information.
  5. (Optional) If you are using serial devices (data terminal equipment), such as a touch panel, connect it to the local console COM (RS-232 DCE) port with a network switch console cable.
  6. (Optional) If you are using serial devices (data communication equipment), such as a PC, connect it to the CPU COM (RS-232 DTE) port with a serial RS-232 DB-9 to RJ-45 Cat5 Ethernet adapter network modem/switch/router cable.
  7. Plug a network cable into one of the unit’s LAN Ports.
  8. (Optional) Plug a second network cable into the other LAN Port for dual LAN operation.
  9. (Optional) For remote boot operation, connect the NC and C terminals to the server/PC.
  10. (Optional) For digital input notifications, connect the GND and DI to an input device (e.g. thermometer, humidity sensor).
  11. Supply power to the unit, thereby turning it on, by plugging the power adapter provided into an AC power source, and plug its cable into one of the unit’s power jacks.
  12. (Optional) Connect the unit to another AC power source using a separate, additional power adapter for power redundancy.
    • Note: A second power adapter can be purchased from your ATEN supplier.

Operation

  1. Open your browser and specify the IP address of the CN9850 you want to access in the browser’s URL location bar.
    • Note: You can get the IP address from the CN9850 administrator, or see the “IP Address Determination” section of the user manual. (Default IP Address: 192.168.0.60)
  2. If a Security Alert dialog box appears, accept the certificate — it can be trusted.
  3. The Login page appears.
  4. Provide a valid username and password.
    • Note: For first-time login, use the default Username and Password: administrator and password.
  5. Click Login to bring up the browser’s main page.

Local IP Setup
Use the local console to set the IP address. All procedures start from the OSD main screen.

  1. To display the main screen, tap [Scroll Lock] twice.
  2. When the login screen appears, enter a valid username and password.
    • Note: For first-time login, use the default Username and Password: administrator and password.

IP Installer

  • Using a Windows PC within the same LAN, users can search for the unit’s IP address or assign an IP address to it with the IP Installer utility.
  • The utility can be obtained from our website www.aten.com.
  • After downloading the utility to the PC, go to the directory that the IP Installer program resides in, and run IPInstaller.exe.

Package Contents

  • 1 CN9850 4K HDMI KVM over IP Switch
  • 1 KVM cable
  • 1 USB cable (USB Type-A to USB Mini-B)
  • 1 control terminal block
  • 1 power adapter and power cord
  • 1 mounting kit
  • 2 HDMI lock pros
  • 1 foot pad set (4 pcs)
  • 1 user instructions

Support and Documentation Notice

  • All information, documentation, firmware, software utilities, and specifi cations contained in this package are subject to change without prior notification by the manufacturer.
  • To reduce the environmental impact of our products, ATEN documentation and software can be found online at http://www.aten.com/download/.
  • Technical Supportwww.aten.com/support.

Scan for more information

Product Page

ATEN-CN9850-AT-E-HDMI-KVM-Over-IP-Switch-FIG-1 \(5\)

User Manual

ATEN-CN9850-AT-E-HDMI-KVM-Over-IP-Switch-FIG-1 \(6\)

The terms HDMI, HDMI High-Defi notion Multimedia Interface, and the HDMI Logo are trademarks or registered trademarks of HDMI Licensing Administrator, Inc. © Copyright 2024 ATEN® International Co. Ltd. ATEN and the ATEN logo are registered trademarks of ATEN International Co., Ltd. All rights reserved. All other trademarks are the property of their respective owners. Part No. PAPE-1223-Z25G Released: 02/2024

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals