FIELD-ADJUSTABLE X34® INSTALLATION

RAB Lighting is committed to creating high-quality, affordable, well-designed and energy-efficient LED lighting and controls that make it easy for electricians to install and end users to save energy. We’d love to hear your comments. Please call the Marketing Department at 888-RAB-1000 or email: marketing@rablighting.com

IMPORTANT
READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE. Fixtures must be wired in accordance with the National Electrical Code and all applicable local codes. Proper grounding is required for safety. THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED.

WARNING : Make certain power is OFF before installing or maintaining fixture. No user-serviceable parts inside. Suitable for Wet locations. Min 90° supply conductors. Fixtures operate at 120V only or 277V only.

KNUCKLE MOUNT
To ensure weather proof seal, apply weather proof silicone sealant around the edge of the junction box (by others). This is especially important with an uneven surface.

  1. Secure the fixture to a 1/2” NPS hole in the junction box or landscape post as shown in Fig. 1. Seal arm thread using Teflon® tape or silicone sealant.
  2. The X34 swivel arm allows 180° of vertical aiming adjustment depending on the mounting position as shown in Fig. 2.

FIELD ADJUSTMENT
Follow instructions below to change the fixture Color Temperature (CCT) and/or Power (W) from the factory settings.

  • Factory Settings:
    • X34XS 16W / 4000K
    • X34S 35W / 4000K
    • X34M 65W / 4000K
  1. Locate the selector switches on bottom of fixture housing as shown in Fig. 3 and 4, remove plug.
  2. Select Color Temperature (CCT) and/or Power (W) by sliding the respective switch to the desired value.
  3. After the switch is positioned to the desired setting replace plug.

WIRING
Driver permits operation at 120V (only) or 277V (only), 50 or 60 Hz as shown in Fig. 5. Connect the black fixture lead to the LINE supply lead.

  1. Connect the white fixture lead to the COMMON supply lead.
  2. Connect the GROUND wire from fixture to supply ground.

CLEANING & MAINTENANCE
CAUTION : Be sure fixture temperature is cool enough to touch. Do not clean or maintain while fixture is energized.

  1. Clean lens with non-abrasive glass cleaning solution.
  2. Do not open the fixture to clean the LEDs. Do not touch the LEDs.

TROUBLESHOOTING

  1. Check that the line voltage at the fixture is correct.
  2. Be sure the fixture is grounded properly.

FIELD-ADJUSTABLE X34® FLOODLIGHT INSTALLATION

RAB Lighting is committed to creating high-quality, affordable, well-designed and energy-efficient LED lighting and controls that make it easy for electricians to install and end users to save energy. We’d love to hear your comments. Please call the Marketing Department at 888-RAB-1000 or email: marketing@rablighting.com

IMPORTANT
READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE. Fixtures must be wired in accordance with the National Electrical Code and all applicable local codes. Proper grounding is required for safety. THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED.

WARNING : Make certain power is OFF before installing or maintaining fixture. No user-serviceable parts inside.
CAUTION : Risk of Fire. Suitable for wet locations. Min 90° supply conductors.

SLIPFITTER MOUNTING

  1. The slipfitter mounting fits a 2 3/8” O.D. Tenon. Place the slipfitter over the Tenon and secure the fixture with (2) Set Screws on the side of the Slipfitter as shown in Fig. 1.
  2. Loosen the Locking Bolt and swivel fixture to desired angle (Fig. 2).
  3. Tighten the Locking Bolt.

TRUNNION MOUNTING

CAUTION : UL certified liquid-tight cord grip suitable for use with three-conductor-type STW flexible cord shall be used for connection to a wet location outlet box provided by others.

To adjust the angle of the fixture using the Trunnion:

  1. Loosen the Pivot Bolts & Angle Locking Screw (Fig. 3).
  2. Adjust fixture to desired angle.
  3. Tighten Pivot Bolts & Angle Locking Screw.

FIELD ADJUSTMENT

Photocell Operation:
This product is equipped with a photocell. Photocell factory setting is set to the “OFF” position. Should you wish to enable the Photocell “ON” feature, slide the center switch to the “ON” position as shown in Fig. 5. If the Photocell is set to the “ON” position and it is daylight, it may take up to 60-seconds for the light to turn off.

Color Temperature (CCT) Selection:
This product is equipped with 5000K, 4000K or 3000K Color Temperature (CCT) selection. For maximum light output use the 4000K Color Temperature (CCT).

Power Selection:

  • X34L is equipped with 90W/80W/70W Power output selection
  • X34XL is equipped with 130W/110W/95W Power output selection.
  • X34XXL is equipped with 160W/140W/120W Power output selection.

Follow instructions below to change Photocell operation, Color Temperature (CCT) and/or Power from factory settings.

Factory Settings: Maximum Power, 4000K CCT, Photocell/OFF.

  1. Locate the selector switches on side of housing as shown in Fig. 4.
  2. Select Color Temperature (CCT), Power and/or Photocell ON/ OFF function by sliding the respective switch to the desired value (Fig. 5).

0-10V DIMMABLE WIRING
Universal voltage driver permits operation at 120V through 277V, 50 or 60 Hz. For 0-10 dimming follow the wiring directions as shown in Fig. 6.

  1. Connect the black fixture lead to the LINE supply lead.
  2. Connect the white fixture lead to the COMMON supply lead.
  3. Connect the GROUND wire from fixture to supply ground. Do NOT connect the GROUND of the dimming fixture to the output.
  4. Connect the purple fixture lead to the DIM V+ lead.
  5. Connect the pink fixture lead to the DIM V- lead.
  6. Internal 12V (aux) wire is capped, DO NOT CONNECT.

CLEANING & MAINTENANCE
CAUTION : Be sure fixture temperature is cool enough to touch. Do not clean or maintain while fixture is energized.

  1. Clean lens with non-abrasive cleaning solution.
  2. Do not open the fixture to clean the LEDs. Do not touch the LEDs.

TROUBLESHOOTING

  1. Check that the line voltage at the fixture is correct. Refer to wiring directions.
  2. Is the fixture grounded properly?
  3. Is the photocell, if used, functioning properly?

Note : These instructions do not cover all details or variations in equipment nor do they provide for every possible situation during installation, operation or maintenance.

Easy Answers
rablighting.com
Visit our website for product info.

Tech Help Line
Call our experts: 888 722-1000.

e-mail:
Answered promptly – sales@rablighting.com

Free Lighting Layouts
Answered online or by request.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals