DITEK DTK-120-240HD2 Whole House Series Surge Protection Installation Guide
- July 12, 2024
- DITEK
Table of Contents
DITEK DTK-120-240HD2 Whole House Series Surge Protection
Product Information
Specifications:
- Model: DTK-120/240HD2
- Manufacturer: DITEK Corporation
- Voltage: 120/240 VAC split phase
- Maximum Surge Current: 100,000 rms symmetrical Amperes
- Recommended Circuit Breaker Size: 30 Amps
Product Usage Instructions
Installation Steps:
- Turn off the power at the main breaker or service disconnect.
- Remove the front cover from the electrical panel.
- Determine the mounting position of the SPD close to the circuit breaker.
- Make a 1/2 knockout in the electrical panel or drill a 1/2 NPT hole.
- Assemble the liquid-tight conduit and connector as per the Illustrations Page.
- Feed all wires, conduit, and connector through the hole in the panel and tighten the locknut.
- Connect the Ground wire (Green) to the Ground bus.
- Connect the Neutral wire (White) to the Neutral bus.
- Connect the Phase wires (Black) to the load side of the circuit breaker.
- Mount the enclosure securely with appropriate anchors.
- Replace the panel cover and restore power after ensuring no hazards exist.
Frequently Asked Questions (FAQ):
-
Q: Can I install this surge protector myself?
A: It is recommended to have a licensed contractor install the surge protector to ensure compliance with all electrical codes and safety standards. -
Q: What is the maximum surge current this device can handle?
A: The DTK-120/240HD2 can handle a maximum surge current of 100,000 rms symmetrical Amperes. -
Q: What is the recommended circuit breaker size for this surge protector?
A: The recommended circuit breaker size is 30 Amps for optimal protection.
NOTICE: This SPD should be installed by a licensed contractor by all applicable National and Local Electrical Codes and the following instructions.
APPLICATION
Type 1 SPD for hardwired installation on a 120/240 VAC split phase electrical service.
INSTRUCTIONS:
Caution: Measure all voltages to verify applied voltage does not exceed
the voltage rating of the unit. Reference the Expected System Voltages chart
below. Improper installation voids the warranty.
INSTALLATION INSTRUCTIONS
NOTE: Suitable for use on a circuit capable of delivering not more than 100,000 rms symmetrical Amperes. The recommended circuit breaker size is 30 Amps. This SPD contains no serviceable parts.
- Turn off the power at the main breaker or service disconnect before beginning installation.
- Remove front cover from the electrical panel.
- Determine the ideal mounting position of the SPD by orienting the unit as close as possible to the position of the circuit breaker selected for the SPD connection.
- Remove a 1/2” knockout in the electrical panel or drill a 1/2” NPT hole in the electrical panel.
- See the Illustrations Page on the back side of this document for instructions on assembling the included liquid-tight conduit and connector. The conduit length can be cut down shorter if desired.
- Remove “Locknut A” from the conduit connector.
- Feed all wires, conduit and 1/2” NPT connector through the knockout hole in the panel, and finally tighten “Locknut A” on the conduit connector.
- Connect the Ground wire (Green) to the Ground bus of the panel.
- Connect the Neutral wire (White) to the Neutral bus of the panel.
- Connect the (2) Phase wires (Black) to the load side of the 2-pole circuit breaker.
- Securely mount the enclosure with appropriate anchors by using the mounting feet located at each corner.
- After all connections have been made and no hazards exist, replace panel cover and restore power.
DRAWN BY: BRIAN AYCOCK 12/13/23
APPROVED BY: MIKE MOLINARI 12/13/23
DITEK TECHNICAL SUPPORT
1-888-472-6100
www.diteksurgeprotection.com
DITEK Corporation
ONE DITEK CENTER
1720 Starkey Road
Largo, FL 33771
Read User Manual Online (PDF format)