DITEK D50-2401 Phase Industrial Surge Protective Device Installation Guide
- August 23, 2024
- DITEK
Table of Contents
DITEK D50-2401 Phase Industrial Surge Protective Device
Specifications :
- Model: D50-2401, D50-240HW
- Manufacturer: DITEK Corporation
- Voltage: 240 VAC single phase
- Type: Type 1 SPD
- Maximum Amperes: 100,000 rms symmetrical Amperes
- Recommended Circuit Breaker Size: 20 Amps
Product Usage Instructions
Installation:
- Turn off the power at the main breaker or service disconnect before beginning installation.
- Remove the front cover from the electrical panel.
- Determine the ideal mounting position of the SPD by orienting the unit as close as possible to the desired position.
Caution :
Measure all voltages to verify applied voltage does not exceed the voltage
rating of the unit. Improper installation voids the warranty
Important Note :
This SPD should be installed by a licensed contractor in accordance with all
applicable National and Local Electrical Codes.
FAQ :
-
Q: What should I do if the applied voltage exceeds the unit’s voltage rating?
A: If the applied voltage exceeds the unit’s voltage rating, do not proceed with the installation. Contact a licensed contractor for further assistance. -
Q: Can the SPD be installed on any circuit?
A: The SPD is suitable for use on a circuit capable of delivering not more than 100,000 rms symmetrical Amperes. The recommended circuit breaker size is 20 Amps.
INSTALL INSTRUCTIONS
D50-2401, D50-240HW
DITEK Corporation
ONE DITEK CENTER 1720 Starkey Road Largo, FL 33771
- NOTICE : This SPD should be installed by a licensed contractor in accordance with all applicable National and Local Electrical Codes and the following instructions.
- APPLICATION
- Type 1 SPD for hardwired installation on a 240 VAC single phase electrical service.
INSTRUCTIONS :
Caution : Measure all voltages to verify applied voltage does not exceed
the voltage rating of the unit. Reference the Expected System Voltages chart
below. Improper installation voids the warranty.
NOTE : Suitable for use on a circuit capable of delivering not more than
100,000 rms symmetrical Amperes. Recommended circuit breaker size is 20 Amps.
This SPD contains no serviceable parts.
- Turn off the power at the main breaker or service disconnect before beginning installation.
- Remove front cover from the electrical panel.
- Determine the ideal mounting position of the SPD by orienting the unit as close as possible to the position of the circuit breaker selected for the SPD connection.
- Remove a 3/4” knockout in the electrical panel or drill a 3/4” NPT hole in the electrical panel.
- Feed all wires through the knockout hole in the panel and tighten the included 3/4” locknut to the SPD fitting.
- Connect the Ground wire (Green) to the Ground bus inside of the panel.
- Connect the Neutral wire (White) to the Neutral bus inside of the panel.
- Connect the Phase wire (Black) to the load side of the single pole circuit breaker.
- If desired, secure the enclosure with appropriate anchors by using the mounting feet on the SPD enclosure.
- After all connections have been made and no hazards exist, replace panel cover and restore power.
DRAWN BY: BRIAN AYCOCK 12/13/23 APPROVED BY: MIKE MOLINARI 12/13/23
DITEK TECHNICAL SUPPORT 1-888-472-6100
www.diteksurgeprotection.com
DOC # INT-100134-001 PART NO. 191566 REV. 5