MEAN WELL LPC-20 series Switching Power Supply Owner’s Manual

July 9, 2024
MEAN WELL

MEAN WELL LPC-20 series Switching Power Supply

MEAN-WELL-LPC-20-series-Switching-Power-Supply-PRODUCT

Specifications

  • Model: LPC-20-350, LPC-20-700
  • Output:
    • Rated Current: 350mA, 700mA
    • DC Voltage Range: 9 ~ 48V, 9 ~ 30V
    • Rated Power: 16.8W, 21W
    • Ripple & Noise (max.): 200mVp-p
  • Input:
    • Voltage Range: 90 ~ 264VAC, 127 ~ 370VDC
    • Frequency Range: 47 ~ 63Hz
  • Efficiency (Typ.): 83%
  • Working Temperature: -30~ +70 (Refer to Derating Curve)
  • Safety Standards: UL879, UL1310, IEC/BS EN/EN 62368-1, EAC TP TC 004, IP67 approved
  • Dimensions: 1183526mm (LWH)
  • Packing: 0.22Kg; 60pcs/14.2Kg/0.72CUFT

Product Usage Instructions

Installation

  1. Ensure input voltage and frequency match the specified range.
  2. Connect the AC/N (Blue) and AC/L (Brown) wires for power input.
  3. Connect the +V (Red) and -V (Black) wires for power output.
  4. Mount the power supply in the recommended direction as per the mechanical specifications.

Safety Guidelines

  • Follow all safety standards and guidelines provided in the user manual to prevent electrical hazards.

Maintenance

  • Regularly check for any signs of damage or wear and tear. Ensure proper ventilation for the power supply unit.

FAQ

Q: What is the maximum number of power supplies that can be connected to a 16A circuit breaker?

A: You can connect up to 8 units with a circuit breaker of type B or up to 14 units with a circuit breaker of type C at 230VAC.

Q: What is the working temperature range of the power supply?

A: The power supply can operate in temperatures ranging from -30°C to +70°C, about the provided Derating Curve.

Q: How should I handle inrush current during a cold start?

A: The power supply has an inrush current of 0.35A/230VAC during cold start. Ensure proper handling to avoid any operational issues.

Features

  • Constant current design
  • Universal AC input / Full range
  • Withstand 300VAC surge input for 5 seconds
  • Protections: Short circuit / Over voltage
  • Cooling by free air convection
  • Small and compact size
  • Fully encapsulated with IP67 level (Note.7)
  • Fully isolated plastic case
  • Class II power unit, no FG
  • Class 2 power unit
  • Pass LPS
  • Suitable for LED-related fixtures or appliances such as LED Decoration or Advertisement devices) (Note.10)
  • 100% full load burn-in test
  • Low cost, high reliability
  • 2 years warrantyMEAN-WELL-LPC-20-series-Switching-Power-Supply-FIG-2

GTIN CODE

SPECIFICATION

MODEL LPC-20-350 LPC-20-700
OUTPUT RATED CURRENT 350mA
DC VOLTAGE RANGE 9 ~ 48V 9 ~ 30V
RATED POWER 16.8W 21W
RIPPLE & NOISE (max.) **Note.2** 200mVp-p 200mVp-p
VOLTAGE TOLERANCE Note.3 ±5.0%
CURRENT ACCURACY ±5.0%
LINE REGULATION ±1.0%
LOAD REGULATION ±2.0%
SETUP, RISE TIME Note.6 500ms, 250ms / 230VAC  500ms, 250ms /

115VAC at full load
HOLD UP TIME (Typ.)| 50ms/230VAC            16ms/115VAC at full load
INPUT| VOLTAGE RANGE| Note.4| 90 ~ 264VAC           127 ~ 370VDC
FREQUENCY RANGE| 47 ~ 63Hz
EFFICIENCY (Typ.)| 83%
AC CURRENT (Typ.)| 0.55A/115VAC  0.35A/230VAC
INRUSH CURRENT(Typ.)| COLD START 70A(twidth=220μs measured at 50% Ipeak) at 230VAC
MAX. No. of PSUs on 16A CIRCUIT BREAKER| 8 units (circuit breaker of type B) / 14 units (circuit breaker of type C) at 230VAC
LEAKAGE CURRENT| 0.25mA / 240VAC
PROTECTION| OVERVOLTAGE| 50.4 ~ 60V| 31.5 ~ 40.5V
Protection type: Shut off o/p voltage, clamping by Zener diode
ENVIRONMENT| WORKING TEMP.| -30~ +70℃ (Refer to “Derating Curve”)
WORKING HUMIDITY| 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 ~ +80℃, 10 ~ 95% RH
TEMP. COEFFICIENT| ±0.03%/℃ (0 ~ 50℃)
VIBRATION| 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along the X, Y, and Z axes
SAFETY & EMC| SAFETY STANDARDS| UL879, UL1310 , CSA C22.2 No. 207-M89(except for LPC-20-350), CAN/CSA C22.2 No. 223-M91(except for LPC-20-350),

IEC/BS EN/EN 62368-1, EAC TP TC 004, IP67 approved

WITHSTAND VOLTAGE| I/P-O/P:3KVAC
ISOLATION RESISTANCE| I/P-O/P:>100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION| Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2 Class A, BS EN/EN61000-3-3, EAC TP TC 020
EMC IMMUNITY| Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035, light industry level, EAC TP TC 020

OTHERS

| MTBF| 5708.9K hrs min.     Telcordia SR-332 (Bellcore);      700.1K hrs min.| MIL-HDBK-217F (25℃)
DIMENSION| 1183526mm (LWH)
PACKING| 0.22Kg; 60pcs/14.2Kg/0.72CUFT
NOTE| 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load, and 25℃ of ambient temperature.

2.  Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.

3.  Tolerance: includes set up tolerance, line regulation, and load regulation.

4.  Derating may be needed under low input voltage. Please check the static characteristics for more details.

5.  The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify the EMC Directive on the complete installation.

(as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf)

6.  Length of set up time is measured at the first cold start. Turning ON/OFF the power supply may lead to an increase in the set-up time.

7.  Suitable for indoor use or outdoor use without direct sunlight exposure. Please avoid immersing in the water for over 30 minutes.

8.  The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitudes higher than 2000m(6500ft).

9.  For any application note and IP waterproof function installation caution, please refer to our user manual before using. https:// www.meanwell.com/Upload/PDF/LED EN.pdf

10. This product is not intended for LED lighting luminaire applications in the EU. (In the EU the LPF/NPF/XLG series are recommended.)

※ Product Liability Disclaimer For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

Mechanical Specification

MEAN-WELL-LPC-20-series-Switching-Power-Supply-FIG-4

Recommend Mounting DirectionMEAN-WELL-LPC-20-series-Switching-Power-
Supply-FIG-5

Block Diagram

MEAN-WELL-LPC-20-series-Switching-Power-Supply-FIG-6

Derating Curve

Static Characteristics

Documents / Resources

| MEAN WELL LPC-20 series Switching Power Supply [pdf] Owner's Manual
LPC-20-350, LPC-20-700, LPC-20 series Switching Power Supply, LPC-20 series, Switching Power Supply, Power Supply, Supply
---|---

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

MEAN WELL User Manuals

Related Manuals