MEAN WELL RPS-120S Series 120W 3×2 Reliable Green Medical Power Supply Owner’s Manual

July 4, 2024
MEAN WELL

MEAN WELL RPS-120S Series 120W 3×2 Reliable Green Medical Power Supply

MEAN WELL RPS-120S Series 120W 3×2 Reliable Green Medical Power Supply

User,s Manual

Features

  • 3″x2″ compact size
  • 120W convention, 150W peak (1 0sec.)
  • Medical safety approved (2 x MOPP) accroding to ANSI/AAMI ES60601 -1 and IEC/BS EN/EN60601 -1
  • Suitable for BF application with appropriate system consideration
  • EMI for both Class I & Class II configuration
  • -30~+85°C wide range operating temperature
  • No load power consumption<0.3W
  • Extremely low leakage current
  • Protections: Short circuit / Overload / Over voltage / Over temperature
  • Operating altitude up to 4000 meters (Note.6~
  • 3 years warranty

Features

Applications

  • Oral irrigator
  • Hemodialysis machine
  • Medical monitors
  • Sleep apnea devices
  • Pumps machine

Applications

GTIN CODE

MW Search: https://www.meanwell.com/serviceGTIN .aspx

Description

RPS-120S is a 120W highly reliable green PCB type medical power supply with a high power density on a 3″ by 2″ footprint. It accepts 80~264VAC input and offers various models with the output voltages between 12V and 48V. The working efficiency is up to 94% and the extremely low no load power consumption is down below 0.3W. RPS-120S is able to be used for both Class I (with FG) & Class TI (no FG) system design. The extremely low leakage current is less than 150μ A. In addition, it conforms to the international medical regulations (2*MOPP) and EMC BS EN/EN55011, perfectly fitting all kinds of BF rated “patient contact” medical system equipment.

Model Encoding

Model Encoding

SPECIFICATION

MODEL| RPS-120S-12| RPS-120S-15| RPS-120S 24| RPS- 120S-27| RPS-120S-48
---|---|---|---|---|---
OUTPUT| DC VOLTAGE| 12V| 15V| 24V| 27V| 48V
CURRENT| Peak(10 sec.)| 11.8A| 9.5A| 6.25A| 5.55A| 3.125A
Convection| 9.5A| 7.6A| 5A| 4.44A| 2.5A
RATED POWER| Peak(10 sec.)| 141.6W| 142.5W| 150W| 149.8W| 150W
Convection| 114W| 114W| 120W| 119.9W| 120W
RIPPLE & NOISE (max.) **Note.2| 100mVp-p| 120mVp-p| 150mVp-p| 150mVp-p| 200mVp-p
VOLTAGE ADJ. RANGE| 11.4~12.6V| 14.3~15.8V| 22.8~25.2V| 25.6 ~ 28.4V| 45.6 ~50.4V
VOLTAGE TOLERANCE Note.3| ±2.0%| ±2.0%| ±1.0%| ±1.0%| ±1.0%
LINE REGULATION| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%
LOAD REGULATION| ±1.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%
SETUP, RISE TIME| 600ms, 30ms/230VAC            600ms, 30ms/115VAC at full load
HOLD UP TIME (Typ.)| 15ms/230VAC             15ms/115VAC at full load
INPUT| VOLTAGE RANGE Note.4| 80 ~ 264VAC            113 ~ 370VDC
FREQUENCY RANGE| 47 ~ 63Hz
POWER FACTOR| PF>0.94/230VAC          PF>0.98/115VAC at full load
EFFICIENCY (Typ.)| 91%| 92%| 93%| 94%| 93.5%
AC CURRENT (Typ.)| 2.3A/115VAC             1.1A/230VAC
INRUSH CURRENT (Typ.)| COLD START     30A/115VAC 60A/230VAC
LEAKAGE CURRENT(max.) Note.5| Earth leakage current < 150μA/264VAC , touch current < 80μA/264VAC
PROTECTION| OVERLOAD| 130~160% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
OVER VOLTAGE| 13.2 ~ 15.6V| 16.5 ~ 19.5V| 26.4 ~ 31.2V| 29.7 ~ 35V| 52.8 ~ 62.4V
Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE| Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
ENVIRONMENT| WORKING TEMP.| -30 ~ +85℃ (Refer to “Derating Curve”)
WORKING HUMIDITY| 20 ~ 90% RH non-condensing
STORAGE TEMP.| -40 ~ +85℃
TEMP. COEFFICIENT| ±0.03%/℃ (0 ~ 50℃)
VIBRATION| 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
OPERATING ALTITUDE Note.6| 4000 meters
SAFETY & EMC**

(Note 7)

| SAFETY STANDARDS| IEC 60601-1:2005+A1+A2, TUV BS EN/ EN 60601-1:2006+A1+A12+A2, ANSI/AAMI ES60601-1:2005+A2

CAN/CSA C22.2 No. 60601-1:2014+A2, EAC TP TC 004 approved; Design refer to BS EN/EN60335-1(by request)

ISOLATION RESISTANCE| Primary-Secondary: 2xMOPP, Primary-Earth:1xMOPP, Secondary-Earth:1xMOPP
WITHSTAND VOLTAGE| I/P-O/P:4KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC
ISOLATION RESISTANCE| I/P-O/P, I/P-FG, O/P-FG: 100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION| Parameter| Standard| Test Level / Note
Conducted emission| BS EN/EN55011 (CISPR11)| Class B
Radiated emission| BS EN/EN55011 (CISPR11)| ClassⅠ: Class B , Class Ⅱ: Class A
Harmonic current| BS EN/EN61000-3-2| Class A
Voltage flicker| BS EN/EN61000-3-3| —–
EMC IMMUNITY| BS EN/EN60601-1-2
Parameter| Standard| Test Level / Note
ESD| BS EN/EN61000-4-2| Level 4, 15KV air ; Level 4, 8KV contact
RF field susceptibility| BS EN/EN61000-4-3| Level 3, 10V/m( 80MHz~2.7GHz )

Table 9, 9~28V/m( 385MHz~5.78GHz )

EFT bursts| BS EN/EN61000-4-4| Level 3, 2KV
Surge susceptibility| BS EN/EN61000-4-5| Level 4, 4KV/Line-FG; 2KV/Line-Line
Conducted susceptibility| BS EN/EN61000-4-6| Level 3, 10V
Magnetic field immunity| BS EN/EN61000-4-8| Level 4, 30A/m
Voltage dip, interruption| BS EN/EN61000-4-11| 95% dip 1 periods, 30% dip 25 periods,

95% interruptions 250 periods

OTHERS| MTBF| 4050.3K hrs min.       Telcordia SR-332 (Bellcore) ; 468.0K hrs min.       MIL-HDBK-217F (25℃)
DIMENSION (LWH)| 76.250.828mm or 3″ 2″ 1.1″ inch
PACKING| 0.13Kg; 100pcs/14Kg/1.13CUFT
NOTE|

  1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
  2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1μf & 47μf parallel capacitor.
  3. Tolerance : includes set up tolerance, line regulation and load regulation.
  4. Derating may be needed under low input voltages. Please check the derating curve for more details.
  5. Touch current was measured from primary input to DC output.
  6. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
  7. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”

(as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )

※ Product Liability Disclaimer: For detailed information, please refer tohttps://www.meanwell.com/serviceDisclaimer.aspx

Block Diagram

Block Diagram

Derating Curve

Derating Curve

AMBIENT TEMPERATURE(c)

Output Derating VS Input Voltage

Output Derating VS Input Voltage

INPUT VOLTAGE (VAC) 60HZ

Mechanical Specification

Mechanical Specification

Mechanical Specification

AC Input Connector (CN1): JST 83P-VH or equivalent

Pin No.

|

Assignment

|

Mating Housing

|

Terminal

---|---|---|---

1

|

AC/L

|

JST VHR or equivalent

|

JST SVH-21T-P1.1 or equivalent

2

|

No Pin

3

|

AC/N

DC Output Connector (CN100): JST 84P-VH or equivalent

Pin No.

|

Assignment

| Mating Housing| Terminal
---|---|---|---

1,2

|

+V

|

JST VHR or equivalent

|

JST SVH-21T-P1.1 or equivalent

3,4

|

-V

  1. HS1 must have safety isolation distance with system case.

Note:

  1. RPS-120S model delivers EMI Class B for both conducted emission and radiated emission for the power supply, when configured into Class I (with FG) system.
  2. RPS-120S model delivers EMI Class 8 conducted emission and Class A radiated emission with King Core K58 RC (12157) in output cable for the power supply when configured into Class U (no FG) system.

Installation Manual

Please refer to: http://www.meanwell.com/manual.html

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>