SAFETY SECTION

Important: This document contains a wiring diagram, a parts list, and service information. This is customer property and is to remain with this unit. Please return to service information pack upon completion of work.

WARNING: HAZARDOUS VOLTAGE
Failure to follow this Warning could result in property damage, severe personal injury, or death. Disconnect all electric power, including remote disconnects before servicing. Follow proper lockout/tagout procedures to ensure the power cannot be inadvertently energized.

SAFETY AND ELECTRICAL HAZARD
Failure to follow this Warning could result in property damage, severe personal injury, or death. These servicing instructions are for use by qualified personnel only. To reduce the risk of electrical shock, do not perform any servicing other than that contained in these operating instructions unless you are qualified to do so.

CAUTION: GROUNDING REQUIRED
Failure to inspect or use proper service tools may result in equipment damage or personal injury. Reconnect all grounding devices. All parts of this product that are capable of conducting electrical current are grounded. If grounding wires, screws, straps, clips, nuts, or washers used to complete a path to ground are removed for service, they must be returned to their original position and properly fastened.

WARNING: UNIT CONTAINS R-410A REFRIGERANT!
Failure to use proper service tools may result in equipment damage or personal injury. R-410A operating pressure exceeds the limit of R- 22. Proper service equipment is required. Service using only R-410A Refrigerant and approved POE compressor oil.

SAFETY HAZARD
Operating the unit without the access panels properly installed may result in severe personal injury or death. Do not operate the unit without the evaporator fan access panel or evaporator coil access panel in place. This product can expose you to chemicals including lead, which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.

General Information

Follow these instructions to install the Single-Point Power Entry Kit (SPEK) in single packaged units.

  1. Check for any shipping damage, and if any, report it to the carrier immediately.
  2. Check the single power entry kit nameplate to ensure available power supply complies with the particular single power entry kit, heater and unit model being used.
  3. The field electrical connections and wiring must be done in accordance with the “National Electrical Code” and must comply with local electrical codes.

Install Single Power Entry Kit

  1. Remove the Control/Heat panel.
  2. Mount the SPEK below the Heater Controls. Secure the SPEK with the screws provided in the kit. See illustrations and wiring diagrams throughout this guide.
  3. The unit power wires provided with the SPEK will pass through Control box base and be routed up to the unit contactor.
  4. Make all electrical connections to the unit and heater in accordance with the appropriate wiring diagram in this instruction and included with the specific SPEK.
  5. Place the included SPEK wiring diagram on the inner surface of the Control/Heater access panel next to the unit wiring diagram and extra heater wiring diagram.

Important

  • The two (2) nameplate labels included with the single power entry kit must be attached to the air conditioning unit or heat pump unit as illustrated in Figure 1, p. 3
  • The smaller label MMUUSSTT be placed over the unit rating nameplate to cover the unit only MCA and Fusing.
  • Check the appropriate kit, heaters and unit combination using the tables in this guide.

High Voltage Field Wiring
Note: All field wire to be rated 75°C minimum. Maximum field wire size is 2/0 AWG.

  1. Check to make certain the proper ampacity and max fuse/circuit breakers for the particular SPEK are being used.

  2. Remove the required electrical knockout from the unit conduit panel and route the field wires through the unit heater section (not the Control Box section).

  3. Connect the power supply to the terminal block on the SPEK. See appropriate wiring diagram for hookup connections. Connect the power supply ground wire to the ground lug on the single power entry kit. The BAYSPEK072 wire terminals connect to the installed heater terminal block on the Heater
    Control box base to power the unit.

  4. Reinstall the Control/Heat access panels.

  5. Apply power to the unit.

Low VoltageWiring (24 Volts)

All lower voltage connections have been made to the heater via polarized plugs. The low voltage controls are connected to the room thermostat from the air conditioner or heat pump low voltage leads. See the field wiring diagram with the unit.

Single Point Power Entry Kit Label Positions

Goodman-BAYSPEK070-Single-Point-Entry-Kit-FIG-1

BAYSPEK with Heater Models

Goodman-BAYSPEK070-Single-Point-Entry-Kit-FIG-2Goodman-BAYSPEK070-Single-Point-Entry-Kit-FIG-3 LABEL-NAMEPLATE 070, 071, and 072 (AC Models)

INSTALLER OF THE STNGLE POWER ENTRY KT MUS | CHECK THE APPROPR ATE BOx ABOVETO RECORD THE KIT HE ATER AND UNTMODEL NUMBERS NSTALLED. POWER SUPPLY_ VOL TAGE TO_UN IT AND_HEATER MUST BE IDENTICAL. CHECK THE UNIT AND HEATER NAMEPLATES TO DETERMINE THE CORRECT POWER SUPPLY VOL TAGE CHECK HEATER NAMEPLATE TO DETERMINE HEATER KW AND CURRENT RATING . MINIMUM INSTALLATION CLEARANCE TO COMBUSTIBLE MATERIAL WHEN_ELECTRIC HEATERS ARE NSTALLEDUNI TT_CABINET-0″, PLENUM-0″ AND OUTLET DUCT- 0″. *INDICATES AN ALPHA CHARACTER.

  • PLACE ABOVE LABEL OVER “ELECTRIC HEATER INSTALLED” NAMEPLATE ON UNIT

LABEL-NAMEPLATE 070, 071, and 072 (HP Models)

Goodman-BAYSPEK070-Single-Point-Entry-Kit-FIG-4 Goodman-BAYSPEK070-Single-Point-Entry-Kit-FIG-5

  • Trane U.S. Inc.
  • Manufacturer of Amer can Standard HVAC

TNSTALLER OF THE STNGLE POWER ENTRY KTT MUST CHECK THE APPROPRTATE BOX ABOVE T0 RECORD THE KTT, HEATER AND UNT MODEL NUMBERS INSTALLED. POWER SUPPLYVOL TAGE TO_UNIT ANDHEATER MUST BETDENTICAL. CHECK THE UNIT AND HEATER NAMEPLATES TO DETERMINE THE CORRECT POWER SUPPL CHECK HEATER NAMEPLATE TO DETERMINE HEATER KW AND CURRENT RATING.MINIMUM TNSTALLATTON_CLEARANCE TO_COMBUSTTBLE MATERIAL WHEN_ELECTRIC HEATERS ARE INSTALLED: UNTTCABI NET-0″, PLENUM – 0″ AND OUTLET DUCT- 0″

  • ND ICATES AN ALPHA CHARACTER.

ABOVE LABEL OVER “ELECTRIIC PLACE HEATER INSTALLED” NAMEPLATE ON UNIT

BAYSPEK with Heater Models

Single Point Assembly Location – Generic Representation

Goodman-BAYSPEK070-Single-Point-Entry-Kit-FIG-6

BAYSPEKO70Goodman-BAYSPEK070-Single-Point-Entry-Kit-
FIG-7
BAYSPEK071Goodman-BAYSPEK070-Single-Point-Entry-Kit-
FIG-8

BAYSPEKO72

Goodman-BAYSPEK070-Single-Point-Entry-Kit-FIG-9Goodman-BAYSPEK070-Single-Point-Entry-Kit-FIG-10

About Trane and American Standard Heating and Air Conditioning
Trane and American Standard create comfortable, energy efficient indoor environments for residential applications. For more information, please visit www.trane.com or www.americanstandardair.com.
The manufacturer has a policy of continuous data improvement and it reserves the right to change design and specifications without notice. We are committed to
using environmentally conscious print practices.

88-MACCO13-1G-EN 14 Oct 2022
Supersedes 88-MACCo13-1F-EN (June 2022)