Model: GSM36U series
-
Output Voltage: 5V, 7.5V, 9V, 12V, 15V, 18V,
24V, 48V -
Rated Current: 0.75A – 4.5A
-
Rated Power: 22.5W (max.)
-
Efficiency: 80% – 88%
-
Input Voltage Range: 80 – 264VAC
-
Frequency Range: 47 – 63Hz
-
Working Temperature: -25°C to +60°C
-
Isolation Level: Primary-Secondary: 2xMOPP;
I/P-O/P: 4KVAC -
EMC: FCC PART 15 / CISPR22 Class B
-
MTBF: 3777.8K hrs min.
Product Usage Instructions
1. Installation
Ensure the input voltage is within the specified range (80 –
264VAC) before connecting the adaptor to the power source.
2. Connection
Connect the appropriate DC plug to the device requiring power.
Refer to the user manual for details on compatible connectors.
3. Power On
Turn on the power source after making all connections. The
adaptor will provide the specified output voltage based on the
settings.
4. Safety
Observe the safety standards and precautions mentioned in the
user manual to ensure safe operation of the adaptor.
Frequently Asked Questions (FAQ)
Q: What should I do if the adaptor gets overheated during
use?
A: If the adaptor overheats, immediately disconnect it from the
power source and allow it to cool down before using it again.
Q: Can I use this adaptor with devices that require a higher
voltage than specified?
A: No, it is not recommended to use the adaptor with devices
that require a higher voltage than what is specified in the user
manual to prevent damage to the devices.
Q: How can I check if the adaptor is functioning properly?
A: You can use a multimeter to measure the output voltage of the
adaptor to ensure it matches the specified voltage levels.
“`
36W AC-DC Reliable Green Medical Adaptor
GSM36U series
User’s Manual
Video
ANSI/AAMI ES60601-1/-1-11 IEC60601-1/-1-11 TPTC004
++
×
https://www.meanwell.com/serviceGTIN.aspx
https://www.meanwell.com/upload/pdf/DC_plug.pdf
×
Downloaded from Arrow.com.
{ × ×
File Name:GSM36U-SPEC 2024-04-26
36W AC-DC Reliable Green Medical Adaptor
GSM36U series
SPECIFICATION
ORDER NO.
GSM36U05-P1J GSM36U07-P1J GSM36U09-P1J GSM36U12-P1J GSM36U15-P1J GSM36U18-P1J GSM36U24-P1J GSM36U48-P1J
SAFETY MODEL NO.
GSM36U05 GSM36U07 GSM36U09 GSM36U12 GSM36U15 GSM36U18 GSM36U24 GSM36U48
DC VOLTAGE
Note.2 5V
7.5V
9V
12V
15V
18V
24V
48V
RATED CURRENT
4.5A
4.32A
4A
3A
2.4A
2A
1.5A
0.75A
CURRENT RANGE
0 ~ 4.5A
0 ~ 4.32A 0 ~ 4A
0 ~ 3A
0 ~ 2.4A
0 ~ 2A
0 ~ 1.5A
0 ~ 0.75A
OUTPUT
RATED POWER (max.)
22.5W
RIPPLE & NOISE (max.) Note.3 80mVp-p
VOLTAGE TOLERANCE Note.4 ±6.0%
32.4W 80mVp-p ±5.0%
36W 80mVp-p ±5.0%
36W 120mVp-p ±3.0%
36W 120mVp-p ±3.0%
36W 150mVp-p ±3.0%
36W 180mVp-p ±2.0%
36W 240mVp-p ±2.0%
LINE REGULATION Note.5 ±1.0%
LOAD REGULATION
±6.0%
±1.0% ±5.0%
±1.0% ±5.0%
±1.0% ±3.0%
±1.0% ±3.0%
±1.0% ±3.0%
±1.0% ±2.0%
±1.0% ±2.0%
SETUP, RISE TIME Note.6 500ms, 30ms / 230VAC 1000ms, 30ms / 115VAC at full load
HOLD UP TIME (Typ.)
16ms / 230VAC 10ms / 115VAC at full load
VOLTAGE RANGE Note.7 80 ~ 264VAC 113 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
INPUT EFFICIENCY (Typ.)
80%
83%
84%
86%
87%
87%
87%
88%
AC CURRENT (Typ.)
0.9A / 115VAC 0.45A / 230VAC
INRUSH CURRENT (Typ.) 55A / 230VAC 30A / 115VAC LEAKAGE CURRENT(max.) Touch current < 50A/264VAC
OVERLOAD PROTECTION
OVER VOLTAGE
105 ~ 170% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed 5.25 ~ 7.5V 7.88 ~ 10.5V 9.45 ~ 13V 12.6 ~ 17.2V 15.75 ~ 20.25V 18.9 ~ 25.2V 25.2 ~ 32.4V 50.4 ~ 64.8V Protection type : Shut down o/p voltage, re-power on to recover
WORKING TEMP.
-25 ~ +60 (Refer to “Derating Curve”)
WORKING HUMIDITY
20% ~ 90% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85, 10 ~ 95% RH non-condensing
TEMP. COEFFICIENT
±0.03% / (0~40)
VIBRATION SAFETY STANDARDS
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
IEC 60601-1:2005+A1+A2; IEC 60601-1-11:2015+A1, ANSI/AAMI ES60601-1:2005+A2;
ANSI/AAMI HA60601-1-11+A1 CAN/CSA C22.2 No. 60601-1:2014+A2; CSA C22.2 NO.
60601-1-11:2015+A1, EAC TP TC 004 approved
ISOLATION LEVEL
SAFETY & WITHSTAND VOLTAGE
EMC (Note. 8)
ISOLATION RESISTANCE
EMC EMISSION
Primary-Secondary: 2xMOPP I/P-O/P:4KVAC I/P-O/P:100M Ohms / 500VDC / 25/ 70% RH
Parameter
Standard
Conducted emission
FCC PART 15 / CISPR22
Test Level / Note Class B
Radiated emission
FCC PART 15 / CISPR22
Class B
MTBF
3777.8K hrs min. Telcordia SR-332 (Bellcore) ; 651.4K hrs min. MIL-HDBK-217F (25)
OTHERS DIMENSION PACKING
795433mm (LWH) 215g ; 60pcs / 13.9Kg / CARTON
PLUG CONNECTOR
CABLE
See page 4~5 ; Other type available by customer requested See page 4~5 ; Other type available by customer requested
NOTE
1. All parameters are specified at 115VAC input, rated load, 25 70% RH
ambient. 2. DC voltage: The output voltage set at point measure by plug
terminal & 50% load. 3. Ripple & noise are measured at 20MHz by using a 12″
twisted pair terminated with a 0.1F & 47F capacitor. 4. Tolerance: includes
set up tolerance, line regulation, load regulation. 5. Line regulation is
measured from low line to high line at rated load. 6. Length of set up time is
measured at first cold start. Turning ON/OFF the power supply may lead to
increase of the set up time. 7. Derating may be needed under low input
voltage. Please check the derating curve for more details. 8. The power supply
is considered as an independent unit, but the final equipment still need to
re-confirm that the whole system complies with the
EMC directives. For guidance on how to perform these EMC tests, please refer
to “EMI testing of component power supplies.” (as available on
https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf ) Product Liability
DisclaimerFor detailed information, please refer to
https://www.meanwell.com/serviceDisclaimer.aspx
Downloaded from Arrow.com.
File Name:GSM36U-SPEC 2024-04-26
LOAD (%)
54 17
LOAD (%)
36W AC-DC Reliable Green Medical Adaptor
GSM36U series
Derating Curve
Static Characteristics
100 80 60 40 20
-25
0
10 20 30 40 50 60
70 (HORIZONTAL)
AMBIENT TEMPERATURE ()
100 90 80 70 60 50 40
80 95 100 110 120 140 160 180 200 220 240 264
INPUT VOLTAGE (VAC) 60Hz
Mechanical Specification
UL1185 16AWG 1200±50mm for 5~9V UL1185 16AWG 1800±50mm for 12~48V
Unit:mm
POWER LED
NAME PLATE
79
33
70±10mm
Downloaded from Arrow.com.
File Name:GSM36U-SPEC 2024-04-26
36W AC-DC Reliable Green Medical Adaptor
GSM36U series
DC output plug Standard plug: P1J
P1J 5.5
2.1
11±0.5mm
Pin Assignment
C”+”
Outside
Inside
DC plug changeable through: (1) Customization of the standard part with an
optional DC plug according to the table (MOQ applicable) (2) Quick adapter
accessory (sold separately without MOQ) Please refer to below table and online
selection guide : https://www.meanwell.com/upload/pdf/DC_plug.pdf
Example quick adapter accessory:
Optional DC plug: (Available in customized cable or quick adapter)
Tuning Fork Style
Type No.
A
OD
C
P1I
5.5
P1L
5.5
A
(Straight)
P1M
5.5
C B
P1IR
5.5
P1JR
5.5
P1LR
5.5
(Right-angled)
P1MR
5.5
Barrel Style
Type No.
A
OD
C
P2I
5.5
P2J
5.5
P2L
5.5
A
(Straight)
P2M
5.5
B
C
P2IR
5.5
P2JR
5.5
P2LR
5.5
(Right-angled)
P2MR
5.5
Lock Style
Type No.
A
OD
A
Floating Locking
C
P2S(S761K) 5.53
P2K(761K)
5.53
B
P2C(S760K) 5.53
SWITCHCRAFT original or equivalent P2D(760K)
5.53
B
C
ID
L
Quick Adapter Accessory
2.1
9.5
2.5
9.5
2.5
11.0
2.1
9.5
Available
2.1
11.0
(Current rating: 7.5A max.)
2.5
9.5
2.5
11.0
B
C
ID
L
2.1 9.5
2.1 11.0
2.5 9.5 2.5 11.0
None
2.1
9.5
2.1 11.0
2.5
9.5
2.5 11.0
B
C
ID
L
2.03 12.06 2.54 12.06
None
2.03 9.52
2.54 9.52
Downloaded from Arrow.com.
File Name:GSM36U-SPEC 2024-04-26
36W AC-DC Reliable Green Medical Adaptor
GSM36U series
Min. Pin Style
A
C
B EIAJ equivalent
Center Pin Style
A
C
B
D
EIAJ equivalent
Min. DIN 3 Pin with Lock (male)
1 3
2
KYCON KPPX-3P equivalent
Min. DIN 4 Pin with Lock (male)
23 14
KYCON KPPX-4P equivalent
Min. DIN 4 Pin with Lock (female)
23 14
KYCON KPJX-CM-4S equivalent
DIN 5 Pin (male)
13 425
Stripped and tinned leads
Type No. P3A P3B P3C
Type No. P4A P4B P4C
Type No.
R6B
Type No.
R7B
Type No.
R7BF
Type No.
R1B
Type No.
A
B
C
Quick Adapter
OD
ID
L
Accessory
2.35
0.7 11.0
Available
4.0
1.7
11.0
(Current rating: 5A max.)
4.75
1.7 11.0
A B CD
OD ID
L Center Pin
5.5 3.4 11.0 1.0
Available
(Current rating: 7.5A max.)
6.5 4.4 11.0 1.4
7.4 5.1 11.0 0.6
Pin Assignment
PIN No.
Output
1
+Vo
2
-Vo
Available
(Current rating: 7.5A max.)
3
+Vo
Pin Assignment
PIN No.
Output
1
+Vo
2
-Vo
3
-Vo
4
+Vo
Pin Assignment
PIN No.
Output
1
+Vo
2
-Vo
3
-Vo
4
+Vo
Pin Assignment
PIN No.
Output
1
-Vo
2
-Vo
3
+Vo
4
-Vo
5
+Vo
Pin Assignment
PIN No.
Output
Available
(Current rating: 7.5A max.)
None
Available
(Current rating: 7.5A max.)
L (red)
1 2
1
+Vo
L1 (black) by customer
Length of Land L1 by request
(MW’s standard length, L: 25 mm, L1: 5 mm)
( NOTE: The wire color is for reference only, please refer to the actual
product)
2
-Vo
None
Installation Manual
Please refer to : http://www.meanwell.com/manual.html
Downloaded from Arrow.com.
File Name:GSM36U-SPEC 2024-04-26
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>