sauermann Si-K25 Airflow Cones User Guide
- June 27, 2024
- sauermann
Table of Contents
sauermann Si-K25 Airflow Cones
Product Specifications
- Models: Si-K25, Si-K85, K35, K75, K120, K150
- Measurement Principle: Airflow cone with integrated airflow straightener
- Designed for: Accurate measurements of straight and turbulent airflow
- Features: Compact unibody design, no assembly required
FAQ
Frequently Asked Questions
- Q: What is the purpose of the red point on the hot wire probe?
- A: The red point indicates the reference point for correct positioning of the probe relative to the airflow direction for accurate measurements.
- Q: Are these cones suitable for both exhaust and supply airflow measurements?
- A: Yes, these cones are designed for accurate measurements in both exhaust and supply systems.
Airflow cones are essential instruments for direct measurement of airflow ventilation and air-conditioning systems. Si-K25, Si-K85 cones can be used with the Kimo Ø 100 mm vane anemometers; K35, K75, K120, K150 cones with the Kimo Ø 8 mm hotwire anemometers from Class 110, 210 and 310 portable instruments.
Si-K25, Si-K85 air flow cones
Si-K25, Si-K85 air flow cones with Ø 100 mm vane anemometers
Measurement principle
The Kimo Si-K25 and Si-K85 cones have a built-in honeycomb airflow straightener that reduces turbulence and enables more accurate airflow measurements. They are designed for accurate measurements of both straight and turbulent airflow on all major ventilation grilles and plate outlets, including multidirectional ones.
These cones feature a compact unibody design with no parts to assemble, making them easy to handle, especially in tight spaces.
Put the Ø 100 mm vane probe on the cone
- Open lever and put the vane probe on the end of the cone.
- Put the vane probe at the bottom of the slot and close the lever.
- For a measure in exhaust, put the vane with the arrow turned towards the inside of the cone.
- For a measure in supply, put the vane with the arrow turned towards the outside of the cone.
Put the cone on the air vent
Warning: Hold the cone by the cone handle. Do not hold the assembly by the vane probe handle.
- Position the cone against the wall (the support).
- Centre the cone for best results.
- Make sure the cone is tight against the wall.
Warning
- Do not pull on the probe handle when removing the Ø 100 mm vane probe from the cone.
Airflow measurement
- Refer to the user manual of the handheld anemometer used, in particular the section on display and flow measurement.
Storage
- During storage, the lever dedicated to holding the vane probe should be closed to reduce the risk of damage during storage or transport. Storage temperature: -20 to 60 °C.
K35, K75, K120, K150 air flow cones
K35, K75, K120, K150 air flow cones with Ø 8 mm hotwire anemometers
Measurement principle
- The direction and the homogeneity of the incoming and outcoming air flow are often disrupted by the geometry of the HVAC grilles. Therefore, it is necessary to funnel the flow to the probe’s sensor.
- The probe and its sensing element are located in a well known section of the cone which guarantees a correct measurement.
Put the Ø 8 mm hotwire probe on the cone
- Slide the hotwire anemometer probe red protection towards the bottom of the probe.
- Clip the probe into the slide on top of the cone’s handle.
- Remember to slide the protection back on the sensing element.
Warning: Red point at the bottom of the hot wire probe must face airflow.
Put the cone on the air vent
- Position the cone against the wall (the support).
- Centre the cone for best results.
- Make sure the cone is tight against the wall.
Airflow measurement
- Refer to the user manual of the handheld anemometer used, in particular the section on display and flow measurement.
Contact
Register your product online
- Register your product online to confirm your warranty and benefit from the full Sauermann range.
Customer service portal
Use our Customer service portal to contact us
Sauermann Industrie
- ZA Bernard Moulinet – 24700 – Montpon-Ménestérol – France
- sauermanngroup.com
QSG – Airflow Cones – 08/04/24 –
Non-contractual document – We reserve the right to modify the characteristics
of our products without prior notice.
References