Keychron M7 Wireless Mouse User Manual
- June 26, 2024
- Keychron
Table of Contents
Keychron M7 Wireless Mouse
Specifications
- Type : Wireless Mouse
- Connectivity : 2.4GHz Type-A and Type-C, Bluetooth
- Features : Middle wheel button, Modes toggle, Report rate button, Macro Button
- Indicator Lights : Mouse indicator, Status indicator, Report Rate indicator
- Power Saving : Auto-Sleep mode
Product Usage Instructions
Wired Mode Setup
- Connect the cable to the TYPE-C port of the mouse and the USB port on the device.
- The mouse is ready to use when the indicator lights up.
2.4GHz Mode Setup
- Switch to G mode (2.4GHz mode) on the mouse.
- Connect the 2.4GHz receiver to the device’s USB/Type-C port.
- The mouse is ready for use when the indicator turns green.
Bluetooth Mode Setup
- Switch to B mode (Bluetooth) on the mouse.
- Pair the mouse with a device by searching for Keychron M7 in Bluetooth settings.
- Follow on-screen instructions to complete pairing.
Factory Reset
- To factory reset, hold down both DPI button and Report Rate button for 4 seconds until all LED lights blink three times.
Auto-Sleep Mode
The mouse will go into Auto-Sleep mode after 15 minutes of inactivity in
2.4GHz or Bluetooth mode. Move or click the mouse to wake it up.
Frequently Asked Questions (FAQ):
-
Q: How do I know if my mouse is in pairing mode?
- A: The mouse indicator will slowly blink green for 2.4GHz mode and blue for Bluetooth mode when in pairing mode.
-
Q: How can I improve wireless performance?
- A: For optimal performance, keep the 2.4GHz receiver close to the mouse within 20cm, and use the cable for a lower latency rate.
M7 WIRELESS MOUSE USER MANUAL
USER MANUAL
- Left button
- Right button
- Middle wheel button
- DPI button
- Modes toggle
- Report rate button
- 2.4GHz Type – A receiver
- 12 2.4GHz Type – C receiver
- Forward button
- Mouse indicator
- Backward button
- Macro Button
3 Modes of connection
Wired Mode
- When the mode switch is in “OFF” position, the mouse won’t respond if the cable is not connected.
- Connect the cable to the TYPE-C port of the mouse and the USB port on the device. The mouse is ready to use while the indicator lights up.
When connected by cable, the mode will default to wired mode even if the toggle is in Bluetooth mode or 2.4GHz mode.
2.4GHz Mode
- Switch to “G” mode (2.4GHz mode), and the mouse will automatically turn on 2.4GHz paring. The mouse indicator will slowly flash green.
- Find the 2.4GHz receiver and connect it to the device’s USB/Type-C port. Once successfully connected, the mouse indicator will turn green and stay on for 3 seconds before dimming off. The mouse is now ready for use.
- In 2.4GHz paring mode, the mouse indicator will slowly blink green for 3 minutes. If the mouse is not connected within 3 minutes, the indicator will turn off. If you need to reconnect, hold both the “Left button + Forward button” for 4 seconds to re-enter pairing mode.
If you need to repair the connection in 2.4GHz mode, please unplug the 2.4GHz receiver first. Then, hold both the “Left button + Forward button” for 4 seconds, wait for the green light indicator to start flashing, and plug the 2.4GHz receiver back in to complete the pairing process.
Note: It is recommended that when pairing the M7 in 2.4GHz mode, the mouse should be within 20cm of the receiver.
Bluetooth mode
- Switch to “B” Mode (Bluetooth), and the mouse will automatically turn on Bluetooth pairing mode. The mouse indicator will slowly flash blue.
- Open the Bluetooth settings, search for a device named “Keychron M7”, then click “connect” to complete paring.
- When in Bluetooth pairing mode, the mouse indicator will slowly blink in blue for 3 minutes. If it’s not connected within 3 minutes, the mouse indicator will turn off. If you need to reconnect, you need to hold the “Left button + Forward button” for 4 seconds to re-enter pairing mode. The indicator will slowly blink blue.
- If the M7 is in Bluetooth mode and needs to pair with a new device, hold both the “Left button + Forward button” for 4 seconds and wait for the blue light to flash on. At this point, Bluetooth has re-entered pairing mode, and you can connect the new device to the M7.
Status indicator
DPI indicator
Report Rate indicator
Report Rate = Polling Rate
How to factory reset
Hold down both the “DPI” button and “Report Rate” button for 4 seconds, and
all the LED lights on the mouse will blink. It will blink three times to
indicate that the factory reset is successful.
Auto-Sleep mode
Auto-Sleep mode will not be activated when in wired mode. When in 2.4GHz mode
or Bluetooth mode, the mouse will go to Auto-Sleep mode after 15 minutes of
sitting idle to save the battery. Move or click the mouse to wake it up.
Driver Software
The Keychron M7 mouse driver can be downloaded from
www.keychron.com. if the driver software can’t
connect to the mouse, please contact us for technical support.
Charging indicator explanation
- The mouse is compatible with all USB ports. For the best signal and charging speed, connecting to the USB3.0 port is recommended when charging or in use.
- If the mouse is connected by the USB Type – C cable when charging but not paired with any devices:
- The mouse indicator will stay RED when charging. • The mouse indicator will stay GREEN when fully charged.
Note: The product supports up to 5V charging voltage and 300 mA charging current. We are not responsible for any problems caused by improper recharging.
What’s in the box
Mouse x 1
- Type – C Cable x 1
- Type – C receiver x 1
- Type – A receiver x 1
- Extension Adapter × 1
- Type – A to Type – C adapter x 1
- User manual x 1
Mouse specification
- Size: 127.777.140.5mm
- Weight: 63 $ 3g
- Report Rate(polling rate) : 125(White) – 500(Blue) – 1000 (Red)|
- Sensor: PixArt 3395
- Resolution: 100 – 26000DPI|
- Mouse micro switches : Huano Micro Switch (80 million clicks life time)
- 2.4GHz / Bluetooth connection range: Approx. 10m of open space
- Battery capacity: 600mAh
- Usage duration : 70 Hours
- Recharge time: 2 Hours
- Charging port: Type – C
- Connection mode : 2.4GHz – Bluetooth – Wired
- Device name: Keychron M7
Keychron, Inc. Dover, DE 19901, United State Find us at
@Keychron
@ Keychron
@keychronMK
Designed by Keychron Made in China
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions
- This device may not cause harmful interference, and
- This device must accept any interference received, including interference that may cause undesired operation.
Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
This device and its antenna(s) must not be co-located or operation in conjunction with any other antenna or transmitter.
Radiation Exposure Statement
The device has been evaluated to meet general RF exposure requirement in
portable exposure condition without restriction.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>