SALTO NRF30 BLUEnet Node Wireless Hardware Installation Guide

June 26, 2024
SALTO

SALTO NRF30 BLUEnet Node Wireless Hardware

Installation guide

  • The BLUEnet Node and RFnet Node are part of SALTO wireless system. They work as a bridge, with the SALTO Gateway, between SALTO’s access control software and wireless locks.

Electrical characteristic

Operation conditions

Min Typ Max Unit
Temperature -20 25 70
Humidity 35   85

SALTO RFnet Characteristics


Frequency Range             2400-2483.5 Mhz
Standard                           IEEE 802.15.4

Indoor Radio Range         10/15m

Max output power           5dBm

SALTO BLUEnet Characteristics


Frequency Range             2400-2483.5Mhz
RF Standard                      Bluetooth Low Energy

Indoor Radio Range         10m/15m*

Max output power           8dBm

Cable requirements

Power Supply for SALTO RFnet

Min Typ Max Unit

Input Voltage              7

Current consumption

| 12| 28

45Note 2

| V

mA

Power Supply for BLUENET

Min Typ Max Unit
Input voltage 7 12 28
Current consumption RFNode     45 Note 2
Current consumption RFNet     75 Note 2
  • The environment has a direct impact on the BLUEnet range radiation (metal, concrete walls…) The receiver device must be located facing the product antenna. Please check your product’s BLUEnet antenna position. Recommended connectivity distance: 10m – 15m
    • Note 1 : 1x2x24AWG or UTP CAT5e recommended
    • Note 2 : Power supply must be calculated taking into account SALTO Gateway and Nodes current consumption

Mechanical installation

  • 1 GANG ELECTRICAL STANDARD BOX

Electrical installation

  • RS485 bus termination resistor is needed (ON position) when the node is located at the end of the bus.

Installation example

Signaling

  • The green (RFnet Node) or blue (BLUEnet Node) LED of the device indicates that the device is properly powered.

Operational test

  • Once the product is installed, follow these steps to check the correct operation:
  • When SALTO Gateway and locks are installed, check that the RFnet Node or blueNET Node is active in SALTO’s software.

Maintenance

  • The unit should be tested at least once a year as described in the “Operational test”. Keep the device in a safe place!

Radio information

The environment has a direct impact on the range of radiation (metal, concrete walls…) The receiver device must be located facing the product antenna. Please check your product’s device antenna position. Recommended connectivity distance: 5m – 10m

  • All contents are current at the time of publication. SALTO Systems S.L. reserves the right to change the availability of any item in this catalog, its design, construction, and/or materials.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

SALTO User Manuals

Related Manuals