SALTO NRF30 BLUEnet Node Wireless Hardware Installation Guide
- June 26, 2024
- SALTO
Table of Contents
SALTO NRF30 BLUEnet Node Wireless Hardware
Installation guide
- The BLUEnet Node and RFnet Node are part of SALTO wireless system. They work as a bridge, with the SALTO Gateway, between SALTO’s access control software and wireless locks.
Electrical characteristic
Operation conditions
Min | Typ | Max | Unit |
---|---|---|---|
Temperature | -20 | 25 | 70 |
Humidity | 35 | 85 |
SALTO RFnet Characteristics
Frequency Range 2400-2483.5 Mhz
Standard IEEE 802.15.4
Indoor Radio Range 10/15m
Max output power 5dBm
SALTO BLUEnet Characteristics
Frequency Range 2400-2483.5Mhz
RF Standard Bluetooth Low Energy
Indoor Radio Range 10m/15m*
Max output power 8dBm
Cable requirements
Power Supply for SALTO RFnet
Min | Typ | Max | Unit |
---|
Input Voltage 7
Current consumption
| 12| 28
45Note 2
| V
mA
Power Supply for BLUENET
Min | Typ | Max | Unit |
---|---|---|---|
Input voltage | 7 | 12 | 28 |
Current consumption RFNode | 45 Note 2 | ||
Current consumption RFNet | 75 Note 2 |
- The environment has a direct impact on the BLUEnet range radiation (metal, concrete walls…) The receiver device must be located facing the product antenna. Please check your product’s BLUEnet antenna position. Recommended connectivity distance: 10m – 15m
- Note 1 : 1x2x24AWG or UTP CAT5e recommended
- Note 2 : Power supply must be calculated taking into account SALTO Gateway and Nodes current consumption
Mechanical installation
- 1 GANG ELECTRICAL STANDARD BOX
Electrical installation
- RS485 bus termination resistor is needed (ON position) when the node is located at the end of the bus.
Installation example
Signaling
- The green (RFnet Node) or blue (BLUEnet Node) LED of the device indicates that the device is properly powered.
Operational test
- Once the product is installed, follow these steps to check the correct operation:
- When SALTO Gateway and locks are installed, check that the RFnet Node or blueNET Node is active in SALTO’s software.
Maintenance
- The unit should be tested at least once a year as described in the “Operational test”. Keep the device in a safe place!
Radio information
The environment has a direct impact on the range of radiation (metal, concrete walls…) The receiver device must be located facing the product antenna. Please check your product’s device antenna position. Recommended connectivity distance: 5m – 10m
- All contents are current at the time of publication. SALTO Systems S.L. reserves the right to change the availability of any item in this catalog, its design, construction, and/or materials.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>