Specifications

  • Brand: Ermenrich
  • Model: Ping SM100 Wire Tracker
  • Power Source: Rechargeable lithium batteries
  • Components: Transmitter, receiver, USB cable, earbuds, carry bag, user manual, warranty

Product Usage Instructions

Getting Started

  1. Shift the on/off switch (7) to the ON position to turn the transmitter on.
  2. Shift the on/off switch (7) to the OFF position to turn the transmitter off.
  3. Press and hold the power button (14) for 3 seconds to turn the receiver on/off.
  4. Turn the sensitivity adjustment knob (6) on the transmitter and the sensitivity adjustment knob (15) on the receiver clockwise to adjust the sensitivity levels from 1 to 8.

Charging the Device

The transmitter and the receiver use rechargeable lithium batteries.

Follow these steps to charge the device:

  1. Connect the USB cable to the device and the DC adapter (not included) via a USB plug.
  2. Connect the DC adapter to an AC power supply to charge the device.
  3. When the low battery indicator blinks, immediately charge the device.

Electrical Cable Tracing

  1. Clamp the red alligator clip to the phase wire or positive terminal of the testing cable.
  2. Clamp the black alligator clip to the grounding wire or grounding terminal of the testing cable.
  3. For multicore cables, clamp the red alligator clip to any color core of the cable and then clamp the black alligator clip to the cable shielding or ground.

Frequently Asked Questions

Q: What should I do if the low battery indicator blinks?

A: Immediately charge the device using the provided USB cable and a DC adapter connected to an AC power supply.

Q: How do I adjust sensitivity levels on the transmitter and receiver?

A: Turn the sensitivity adjustment knob clockwise on both the transmitter and receiver to adjust levels from 1 to 8.

OVERVIEW

ERMENRICH-SM100-Ping-Wire-Tracker-FIG-1

  1. Alligator clips
  2. Operation status indicator (ON / Charging / Scan mode)
  3. Charging port
  4. Power cable socket
  5. AUDIO button
  6. Sensitivity adjustment knob
  7. On/off switch
  8. Telephone adapter cable (RJ11)
  9. Operation status indicator
  10. Earphones jack
  11. Signal strength indicator
  12. Speaker
  13. Charging port
  14. Power button
  15. Sensitivity adjustment knob
  16. Sensor
  • Please carefully read the safety instructions and the user manual before using this product. Keep away from children. Use the device only as specified in the user manual.
  • The kit includes  a transmitter with alligator clips, a receiver, a USB cable, earbuds, a carry bag, a user manual, and a warranty.

Getting started

  • Shift the on/off switch (7) to the ON position to turn the transmitter on.
  • Shift the on/off switch (7) to the OFF position to turn the transmitter off.
  • Press and hold the power button (14) for 3 seconds to turn the receiver on/off.
  • Turn the sensitivity adjustment knob (6) on the transmitter and the sensitivity adjustment knob (15) on the receiver clockwise to adjust the sensitivity levels from 1 to 8.

Charging the device

  • The transmitter and the receiver use rechargeable lithium batteries. Connect the USB cable to the device and the DC adapter (not included) via a USB plug and connect it to the AC power supply to charge the device.
  • When the battery is low, the low battery indicator will blink; and immediately charge the device.

Electrical cable tracing

  1. Clamp the red alligator clip to the phase wire or the positive terminal of the testing cable; and clamp the black alligator clip to the grounding wire or the grounding terminal of the testing cable.
    • To trace a multicore cable, clamp the red alligator clip to any color core of the cable and then clamp the black alligator clip to the cable shielding or clamp it to the ground.
  2. Press button (5) to switch the transmitter to the scanning mode.
  3. Turn the sensitivity adjustment knobs (6 and 15) to the maximum sensitivity.
  4. Place the receiver near the cable bundle (or near the surface where the cable is hidden) and move the receiver along the cable to trace it.
    • When the sensor is close to the target cable, the receiver will emit a beeping sound. To detect the cable more accurately, lower the sensitivity.
    • The closer the device is to the object, the louder the signal will be.
    • The maximum voltage of the circuit to be tested with the use of the alligator clips shall not exceed 220V AC.

Telephone cable tracing

  1. Connect a telephone cable or a network cable to the transmitter using the telephone adapter cable (8).
  2. Press button (5) to switch the transmitter to the scanning mode.
  3. Turn the sensitivity adjustment knob (6 and 15) to the maximum sensitivity.
  4. Place the receiver near the cable bundle (or near the surface where the cable is hidden) and move the receiver along the cable to trace it.
    • When the sensor is close to the target cable, the receiver will emit a beeping sound.
    • To detect the cable more accurately, lower the sensitivity.
    • The closer the device is to the object, the louder the signal will be.

Power cable tracing

  1. Connect a power cable to the power cable socket (4) of the transmitter.
  2. Press button (5) to switch the transmitter to the scanning mode.
  3. Turn the sensitivity adjustment knob (6 and 15) to the maximum sensitivity.
  4. Place the receiver near the cable bundle (or near the surface where the cable is hidden) and move the receiver along the cable to trace it.
  • When the sensor is close to the target cable, the receiver will emit a beeping sound. To detect the cable more accurately, lower the sensitivity.
  • The closer the device is to the object, the louder the signal will be.
  • The maximum voltage of the circuit to be tested through connection to the power cable socket of the transmitter shall not exceed 400V.
  • Observe the safety precautions to avoid the risk of electric shock.

Specifications

ERMENRICH-SM100-Ping-Wire-Tracker-FIG-2

The manufacturer reserves the right to make changes to the product range and specifications without prior notice.

Care and maintenance

  • Do not connect the device to a high-voltage wire as it is life-threatening and it will damage the device. To avoid lightning strikes, do not use the device during thunderstorms.
  • The rated voltage of the tested circuit must not be greater than 220V AC / 400V (see Specifications”). Do not use the device if it is not working properly. Protect the device from sudden impact and excessive mechanical force.
  • Do not use the device in humid environments. Store the device in a dry cool place. Please note that the parameters of the power supply must comply with the technical characteristics of the device. Do not touch any bare conductor with your hand or skin.
  • Do not try to disassemble the device on your own for any reason. For repairs and cleaning of any kind, please contact your local specialized service center. Only use accessories and spare parts for this device that comply with the technical specifications.
  • Never attempt to operate a damaged device or a device with damaged electrical parts! If a part of the device or battery is swallowed, seek medical attention immediately.

Battery safety instructions

  • Always purchase the correct size and grade of battery most suitable for the intended use. Always replace the whole set of batteries at one time; taking care not to mix old and new ones or batteries of different types.
  • Clean the battery contacts and also those of the device before battery installation. Make sure the batteries are installed correctly concerning polarity (+ and –). Remove batteries from equipment that is not to be used for an extended time.
  • Remove used batteries promptly. Never short-circuit batteries as this may lead to high temperatures, leakage, or explosion. Never heat batteries to revive them. Do not disassemble batteries. Remember to switch off devices after use.
  • Keep batteries out of the reach of children, to avoid the risk of ingestion, suffocation, or poisoning. Utilize used batteries as prescribed by your country’s laws.

Levenhuk International Warranty

  • Levenhuk products, except for their accessories, carry a 5-year warranty against defects in materials and workmanship. All Levenhuk accessories are warranted to be free of defects in materials and workmanship for six months from the purchase date.
  • The warranty entitles you to the free repair or replacement of the Levenhuk product in any country where a Levenhuk office is located if all the warranty conditions are met.
  • For further details, please visit: levenhuk.com/warranty
  • If warranty problems arise, or if you need assistance in using your product, contact the local Levenhuk branch.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals