VISUAL COMFORT 3AVLR60XXXD Avila LED Ceiling Fan Instruction Manual
- June 21, 2024
- VISUAL COMFORT
Table of Contents
FAN COLLECTION
3AVLR60XXXD Series Fan
cETL Model NO. : 3AVLR60XXXD
Total fan weight with light: 7.7 kg/17 lbs
www.visualcomfort.com
3AVLR60XXXD Avila LED Ceiling Fan
© 2023 Visual Comfort & Co.. All rights reserved. The Visual Comfort & Co.
logo is a registered trademark of Visual Comfort & Co.
Visual Comfort & Co. reserves the right to change specifications for product
improvements without notification.
Cautions and Warnings
WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO
PERSONS, OBSERVE THE FOLLOWING READ AND SAVE THESE INSTRUCTIONS
Installation work and electrical wiring must be done by qualified person(s) in
accordance with applicable codes and standards (ANSI/NFPA 70), including fire-
rated construction.
Use this unit only in the manner intended by the manufacturer. If you have any
questions, contact the manufacturer.
After making the wire connections, the wires should be spread apart with the
grounded conductor and the equipment-grounding conductor on one side of the
outlet box and ungrounded conductor on the other side of the outlet box. The
splices, after being made, should be turned upward and pushed carefully up
into the outlet box.
WARNING: Before you begin installing, servicing or cleaning the fan unit,
switch the power off at the service panel and lock the service panel to
prevent the power from being switched back on accidentally. If the service
panel cannot be locked to prevent the power from being switched on
accidentally, securely fasten a warning sign to the service panel.
Be cautious! Read all instructions and safety information before installing
your new fan. Review the accompanying assembly diagrams.
When cutting or drilling into wall or ceiling, do not damage electrical wiring
and other hidden utilities.
Make sure the installation site you choose allows the fan blades to rotate
without any obstructions. Allow a minimum clearance of 7 feet from the floor to
the trailing edge of the blade.
WARNING: To reduce the risk of fire, electric shock, or personal injury,
mount to outlet box marked “Acceptable for Fan Support of 15.9 kg (35 lbs) or
less” and use mounting screws provided with the outlet box.
CAUTION: Comply with local codes and regulations. If installing the
secondary support safety cable in the U.S., do not remove knockouts in the
outlet box. Mount the secondary support safety cable through the reserved
nail/screw hole on the outlet box to the building structure or the ceiling
joist.
WARNING: To reduce the risk of personal injury, do not bend blade holders
during installation to motor, balancing or during cleaning. Do not insert
foreign object between rotating blades.
Attach the mounting bracket using only the hardware supplied with the outlet
box.
WARNING: To reduce the risk of fire or electric shock, this fan should
only be used with fan speed control part no. FC880RS-DP manufactured by
Shenzhen Funpower General Technology co., Ltd.
WARNING: To reduce the risk of fire or electric shock, do not use this fan
with any other solid state fan speed control device, or variable speed
control.
If this unit is to be installed over a tub or shower, it must be marked as
appropriate for the application.
Never place a switch where it can be reached from a tub or shower.
The combustion airflow needed for safe operation of fuel-burning equipment may
be affected by this unit’s operation. Follow the heating equipment
manufacturer’s guideline safety standards such as those published by the
National Fire Protection Association (NFPA), and the American Society for
Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and the local
code authorities.
CAUTION: To reduce the risk of electric shock, disconnect the electrical
supply circuit to the fan before installing the light kit.
CAUTION: The light source is designed for this specific application and
can overheat if serviced by untrained personnel. If any servicing is required,
the product should be returned to an authorized service facility for
examination or repair.
WARNING: If unusual oscillating movement is observed, immediately stop
using the ceiling fan and contact the manufacturer, its service agent or
suitably qualified persons.
CAUTION: The replacement of parts of the safety suspension system device
shall be performed by the manufacturer, its service agent or suitably qualified
persons.
All set screws must be checked and tightened where necessary before
installation.
Note: Suitable for use in damp locations. Install the fan under covered
or enclosed patios or porches. Use only with light kits marked “Suitable for
use in damp locations”.
Tools Required for Assembly (not included): Electrical Tape, Phillips
Screwdriver, Pliers, Safety Glasses, Stepladder and Wire Strippers Before you
begin installing the fan, Switch power off at Service panel and lock service
disconnecting means to prevent power from being switched on accidentally. When
the service disconnecting means cannot be locked, securely fasten a warning
device, such as a tag, to the service panel. Use AC 120V/60HZ power supply
only. Before installing this fan make sure the outlet box is properly
installed to the house structure. To reduce the risk of fire, electric shock,
or personal injury, mount to outlet box or supporting system acceptable for
fan support.
(Mounting must support at least 35 lbs.) Use metal outlet box suitable for fan
support and use only the screws provided with the outlet box (must support 35
lbs). Before attaching fan to outlet box, ensure the outlet box is securely
fastened by at least two points to a structural ceiling member ( a loose box
will cause the fan to wobble). Install the mounting bracket onto the outlet
box.
Partially loosen the two screws on the outlet box, attach the mounting bracket
onto the outlet box by sliding it over the two screws as shown in the
illustration. Have the mounting bracket in position and tighten the set
screws. Partially loosen downrod set screws from yoke at top of motor
assembly. Remove preassembled cross pin and keeper pin from downrod. Keep
parts. Place downrod over canopy, canopy bottom cap and yoke cover. Thread
lead wires and safety cable from motor assembly through downrod. Slip downrod
into motor housing yoke, aligning holes and install cross pin and keeper pin.
Insert cross pin through yoke and downrod until point appears on the other
side, and insert keeper pin on cross pin.
Pull the downrod up tight against the cross pin, and then evenly tighten the
downrod set screws on motor housing yoke.
Place yoke cover on top housing of fan.
Warning: Cross pin and keeper pin must be installed securely, failure to
install them will result in serious injury. Install ball end of downrod into
mounting bracket opening. Align (engage) slot on ball with tab on mounting
bracket.
Warning: Failure to align slot on ball with tab may result in serious
injury.
Important: If using the angle mount, make sure open end of mounting
bracket is installed facing the higher point of the ceiling and make sure the
ceiling angle is not steeper than 20º. Longer downrod may be necessary
allowing the fan blades to rotate without obstructions. Safety cable must be
installed into the house structure using 3” lag screws, washers, and lock
washers provided, required for outdoor applications and in Canada (All fans
installed in Canada), and for USA fan and light kit combinations over 35lbs.
Make sure that when the safety cable is fully extended the lead wires are
longer than the cable and no stress is placed on the lead wires.
Note: If Installing The Secondary Support Safety Cable in the U.S., Do
Not Remove Knockouts In The Outlet Box. Make wiring connections using wire connectors provided as
indicated above.
Brown wire from fan to Brown wire from receiver marked Motor U.
Gray wire from fan to Gray wire from receiver marked Motor V.
Orange wire from fan to Orange wire from receiver marked Motor W.
White wire from fan marked “For light” to White wire from receiver marked “For
light”.
Blue wire from fan marked “For light” to Blue wire from receiver marked “For
light”.
White (Neutral) wire from house to White wire from remote marked AC IN N.
Black (Live) wire from house to Black wire from remote marked AC IN L.
Connect all green grounded wires to Grounded wire from House.
Make sure that no filaments are outside of the wire connectors.
Insert the remote receiver into mounting bracket.
After making the wire connections, the wires should be spread apart with the
grounded conductor and the equipment-grounding conductor on one side of the
outlet box and ungrounded conductor on the other side of the outlet box. The
splices after being made should be turned upward and pushed carefully up into
the outlet box.
Caution: The installation has to be complete before operate the fan.
Receiver has to be used on the fan and cannot be bypassed. Partially loosen
one and remove one preassembled step screw from mounting bracket (Do not
remove the other set screws). Save the screw.
Lift canopy up, aligning its keyhole slot with the preassembled step screw on
mounting bracket and twist clockwise to lock in place. Reinstall the other
step screw and tighten the screws securely. Attach canopy bottom cap onto
canopy by aligning its holes with the step screws on mounting bracket and fix
it with the magnet embraced. Install a blade onto the flywheel. Align the holes
on the blade and thescrew holes on the flywheel and install it with screws
provided. Repeat this process for remaining blades. Tighten all screws
securely. Loosen 2 and remove 1 preassembled screw from the plate on motor.
Save screw for later use. Place the lead wires from fan over the central hole
of light pan.
Aligning the keyhole slots on the light pan with the preassembled screws on
the plate. Twist clockwise till lock. Reinstall the screw which was just
removed.
Tighten all screws securely.
Loosen 2 and remove 1 preassembled screws from light pan. Keep screw.
Install LED Light Fixture
Connect white wire from fan to white wire from LED light fixture and then
connect blue (or black) wire from fan to black (or blue) wire from LED light
fixture. Be sure plugs connection clasped together firmly.
Attach LED light fixture onto the light pan, aligning the keyhole slots on the
LED light fixture with the preassembled screws on the light pan. Twist
clockwise till lock.
Reinstall the screw which was just removed. Tighten all screws securely.
Note: If you don’t want to install the fan with LED light, go to step 17
for blanking plate installation. Attach glass by locating dimples in light pan
with grooves on the glass and twist clockwise until tight.
Install Blanking Plate
Isolate the quick connects with electrical tape. Attach blanking plate by
locating dimples in light pan with grooves on the blanking plate and twist
clockwise until tight.
Note: Do not install LED light fixture if use blanking plate.
Remote Controller Operation
Remove the battery cover from the remote control transmitter and install
batteries.
Replace the cover. This remote uses 2 1.5V/AAA batteries.
Note: If not using for long periods of time, remove battery to prevent
damage to remote transmitter, and store the remote transmitter away from
excess heat or humidity
Dimming, Non Dimming Setting (Only available for fans with light)
In the dimming mold, it is a light dimming selection and it is to be used with
dimmable luminaries. The remote controller is set with dimming function at
factory.
In ON/OFF (non-dimming mold), it is for light ON/OFF only (non-dimming
function).
Universal Mode and Learning Mode
There are “Universal Mode” and “Learning Mode” (marks “0” and “1”) with the
remote controller.
If choosing “Universal Mode”, simply place dip (code) switch at LOWER position
(mark “0”). Your fan with the remote controller is ready to use.
Note: If using universal mode, your fan can be controlled with other
remote transmitters with the same setting.
To control the fan with specific remote transmitter, choose “Learning Mode” by
placing the dip (code) switch at UPPER (mark “1”) position and then make learn
function setting as below.
Learn Function Setting
Important: Turn the power on for ONLY the specific fan you wish to pair
with the remote controller. Make sure to turn the power off for all other fans
with which you use the same remote controller.
Restore power to your fan, press and hold the “SET” button to pair the
Transmitter and receiver. You must press the ‘SET” button within 60 seconds of
restoring power to the fan.
Note: Fan will operate at minimum speed and light will blinks after the
setting.
Note: If the power is on already, you must turn the power off then turn
the power back for remote control setting.
Note: If reset the dip switch to “0” position (universal mold). It has to
be paired again, run the learn function setting.
The remote control buttons control the fan speed as follows:
Fan speed
1 = minimum speed
2 = low speed
3 = medium low speed
4 = medium speed
5 = medium high speed
6 = high speed
| This button turns the fan off.
---|---
| Forward/Reverse button- This button is to control direction of fan rotation.
Press once to change direction of the fan rotation. Fan must be running to
reverse.
| Light button- Press this button to turn light on or off.
| Light button- Press this button to desired brightness, dim to bright.
| Light button- Press this button to desired brightness, bright to dim.
| Breeze-
Press the Breeze button, the fan will operate at high speed (6th ) for 30
seconds, then automatically change to 5th , 4th , 3rd , 2nd , 1th at intervals
of 30 seconds, and then change it from Low speed (1st ) to 2nd , 3rd , 4th ,
5th , 6th repeat the cycle until the breeze mode is canceled. Breeze mold can
be erase by pressing the buttons of power or speed control.
Note: This remote controller has auto resume function, the fan and light
will maintain the last setting if turned off with exception of the Breeze
mold.
Install Transmitter wall mount cradle with 2 screws provided.
Useful tips:
Take remote transmitter up by pushing it at lower area of the transmitter.
The remote transmitter can be held on magnetic metal materials by a magnet
built in the transmitter.
The receiver
provides the following protective functions
Lock protection- The DC motor has a build-in safety feature against blade
obstruction during operation. If something obstructs the fan blades, the motor
will stop operation after about 20 seconds of interruption. Please remove
obstacles and reset it by turning the power off, and turn it back. Over 40W
protection- When the receiver detects motor power consumption which is greater
than 40W, the fan RPM will be lowered to protect it from overloading.
THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES OPERATION IS SUBJECT TO THE
FOLLOWING TWO CONDITIONS. (1)THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE
AND (2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED, INCLUDING
INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION.
User Tips
-
If your fan is operating automatically after installation, it is still using the factory setting. Follow the settings for Learn Mode above to reset.
-
If the fan or light isn’t working, reset power (turn the power off then turn the power back on) and follow the Universal Mode or Learn Mode remote control settings.
Note: Make learn setting either you change it from universal mode to learn mode or change it back to universal mode from learn mode. -
If two or more fans in the same remote signal range are on the same power supply, they cannot be operated separately by remote control. Use a separate power supply for each fan, such as an individual wall switch, and restrict the power supply to only the fan which you are pairing with its transmitter in order to use the remote controller.
-
When the fan is turned on to oscillate in either forward or reverse direction, it may shudder briefly until fully engaged. This is a normal operation for this fan; the shuddering will quickly cease as movement is engaged.
Troubleshooting
If you have difficulty operating your new ceiling fan, it may be the result of
incorrect assembly, installation, or wiring. In some cases, these installation
errors may be mistaken for defects. If you experience any faults, please check
this Troubleshooting Chart. If a problem cannot be remedied, or you are
experiencing difficulty in installation, please call our Customer Service
Center at the number printed on your parts list insert sheet.
Warning: Before you begin installing, servicing or cleaning the fan unit,
switch the power off at the service panel and lock the service panel to
prevent the power from being switched back on accidentally. If the service
panel cannot be locked to prevent the power from being switched on
accidentally, securely fasten a warning sign to the service panel.
Trouble | Suggested Remedy |
---|---|
1. If fan does not start: | 1. Check main and branch circuit fuses or circuit |
breakers.
2. Check line wire connections to fan and switch wire connections in switch
housing.
CAUTION: Make sure main power is turned off.
3. If this fan uses manual forward/reverse switch, make sure the switch is
pushed firmly either way. Fan will not operate when switch is in the middle.
4. If this fan uses a remote controller, make sure dip switches are in the
correct setting and make sure the battery works.
2. If fan sounds noisy:| 1. Check to make sure atl screws in motor housing
are snug (not over tightened).
2. Check to make sure the screws which attach the fan blade holder to the
motor are tight.
3. Check to make sure wire nut connectors in switch housing are not rattling
against each other or against the interior wall of the switch housing.
CAUTION: Make sure main power is turned off before entering switch housing.
4. Check to be sure lightbulb is tight in socket and not touching the glass
shade.
5. Some fan motors are sensitive to signals from Solid State variable speed
controls.
6. Allow “break-in” period of 24 hours. Most noises associated with a new fan
will disappear after this period.
3. If fan wobbles:|
1. If this is a downrod mount fan, make sure the ridge on mounting bracket
engages the notch in the downrod ball.
2. Make sure that canopy, mounting bracket or mounting plate are tightened
securely to ceiling junction box and junction box is mounted firmly to ceiling
joist.
3. Check that ail blades are screwed firmly into blade holders.
4. Check that all blade holders are tightened securely to motor.
5. Most fan wobble problems are caused when blade levels are unequal. Check
this level by selecting a point on the ceiling above the tip of one of the
blades. Measure this distance from blade tip to ceiting. Keeping measure
within 1/8″, rotate the fan until the next blade is positioned for
measurement. Repeat for each blade. If atl blade levels are not equal, you can
adjust blade levels by the following procedure. To adjust a blade tip down,
insert @ washer (not supplied) between the blade and blade holder at the screw
closest to the motor. To adjust a blade tip up, insert washer (not supplied)
between the blade and blade holder at the two screws farthest from the motor.
Reverse the position of the washer if blades mount from top of blade.
6. If blade wobble is still noticeable, interchanging two adjacent blades can
redistribute the weight and possibly result in smoother operation.
If the above steps do not eliminate the wobble problem, you will need to
dynamically balance your fan with balancing kit provided.
4. If light does not work:| 1. Check blue wire from fan to make sure it is
connected to hot wire from house.
2. Check for loose or disconnected wires in fan switch housing.
3. Check for loose or disconnected wires in light kit.
4. Check for faulty lightbulb and make sure bulb is tight in socket.
5. Remove light kit and check the plug connections if they are present.
6. If this fan uses a remote controller, make sure dip switches are in the
correct setting and make sure the battery works.
CAUTION: Make sure main power is turned off before entering switch housing and/or canopy.
Customer Service
800-969-3347
Customer Service Center
7400 Linder Ave.
Skokie, IL 60077
www.visualcomfort.com