Product Information
The DR-HO’S Neck Pain Pro is a pain therapy device (model P.T.S-IIB) that is
central to the Neck Pain Pro system. It is designed to relieve pain associated
with sore or aching muscles in various parts of the body. The device features
a program button with 3 intensity intervals, an ergonomic self-contouring
design with a breathable cover, a travel clip for easy portability, armrests
for secure electrode placement, an electrode outlet to connect to the Neck
Pain Pro or body pads, an intensity switch to adjust treatment intensity, and
a timer button with 3 treatment time options (10, 20, and 40 minutes).
The device comes with unique built-in electrodes that are clinically proven to
help relax tight muscles, improve circulation, and relieve pain. To ensure
effective treatment, it is recommended to apply DR-HO’S Electro Therapy
Conductive Gel generously over the electrodes before use and respray every 30
minutes during treatment or if any slight stinging sensations occur. The gel
reduces the amount of contact between the electrode surface and the skin,
providing a more comfortable experience.
The Neck Pain Pro system also includes reusable body pads in two sizes, which
provide effective treatment for specific areas of the body. The care
instructions for the Neck Pain Pro device recommend wiping it clean with a
moist cloth and allowing it to air-dry. Submerging it in water or washing it
in a washing machine may damage the electronic components.
Product Usage Instructions
- Choose the appropriate treatment program and duration using the program button and timer button.
- Secure the device to your neck or other desired areas using the arm rests.
- Adjust the intensity of the treatment by turning the intensity switch.
- Apply DR-HO’S Electro Therapy Conductive Gel generously over the electrodes before use and respray every 30 minutes or if slight stinging sensations occur.
- Ensure the electrodes are pressed firmly against your skin for optimal contact.
- Start the treatment and allow the device to automatically end the session at the chosen program’s duration.
- If desired, you can extend the treatment time by selecting a program and its duration again, after first switching off the device.
- Refer to the pad placement chart for guidance on how to position the large or small format pads depending on the area to be treated.
- After each use, wipe the Neck Pain Pro device clean with a moist cloth and allow it to air-dry. Do not submerge it in water or wash it in a washing machine.
- For replacement electrode body pads or conductive gel, visit the website of your supplier or contact them for assistance.
Important Safety Precautions:
- Do not use the Neck Pain Pro system while sleeping, in the bathroom (when taking a bath or having a shower), driving, or operating machinery.
- Treatment may cause involuntary arm movements and may make you drowsy.
OVERVIEW
DR-HO’S Electro Therapy Conductive Gel
This patented gel is developed to moisten the electrodes and the skin, to reduce the amount of contact between the electrode surface and the skin, and to ensure more comfortable and effective treatment.
Mini Spray Bottle
To easily and generously apply the conductive gel over the surface area and edges of the 4 electrodes.
Reusable body pads
The electrode pads, which are available in two sizes, provide effective treatment for specific areas of the body. These zones can be found in the overview on page 6.
IMPORTANT!
DR-HO’S Neck Pain Pro is a medical device class IIA. Please read all guidelines carefully and keep it for future reference
This complete system (the Neck Pain Pro and the electrode body pads) is intended to relieve pain associated with sore or aching muscles in your shoulders, arms, the back of your neck and other parts of your body, due to strain from exercise or activities of daily living, regular household and work activities
Neck Pain Pro care instructions
Wipe clean with a moist cloth and allow to air-dry. Do not submerge in water or wash in the washing machine because water may damage the electronic components.
Note:
Do not use the Neck Pain Pro system while sleeping, in the bathroom (when
taking a bath or having a shower), driving or operating machinery. Treatment
may cause involuntary arm movements and may make you drowsy.
Electrode body pads
- Do NOT use the large and small body pads under your feet.
- If the pads feel dry or irritating, spray them with a small amount of DR-HO’S Electro Therapy Conductive Gel, wait 30 seconds and re-attach the pads to your body.
- For optimal results replace the electrode pads after 30 to 50 sessions.
- Electrode pads are intended for personal use and should not be used by others.
Refer to the pad placement chart on how to position the large or small format pads, depending on the area to be treated. If you wish to order replacement electrode body pads or conductive gel please visit the website of your supplier. If you have any questions, please contact your supplier.
BATTERY INSTRUCTION
- Insert 2 AAA batteries in the back of the device. It is best to use alkaline batteries
- Turn the switch to ‘ON’. Then increase the intensity slowly until your muscles start moving of their own accord.
- Press the ‘Mode’ button to choose from 3 programs with different intensity intervals, A, B or C. A flashing light will indicate the selected mode.
- Press the ‘Time’ button to select the treatment time, 10, 20 or 40 minutes. Turn the switch to ‘OFF’ after your 10, 20 or 40 minutes treatment. To continue the treatment first turn the device off and then back on again.
Neck Pain Pro
- Plug the wire firmly into the top of the device.
- Remove cloths, metal necklaces and jewelry around your neck.
- For the best results, apply the conductive gel to your neck and shoulders.
- Apply generously conductive gel over the entire surface area and edges of all 4 electrodes.
- Rub the gel into the electrodes with your fingers and make sure they are wet.
- Place your arms in the arm rests and pull the Neck Pain Pro against your neck. Lean back or lay down.
Electrode body pads
-
Insert the plug from the selected set of electrode pads into the Pain Therapy Device.
-
To use the pads, remove the transparent protective film from both electrode pads to expose the self-adhesive and sticky gel layer.
-
Spray a little bit of gel evenly over the surface of the pads, using the handy spray bottle supplied.
-
Refer to the pad placement chart on page 6.
Note : The system ONLY works if you attach both pads from the same set to your body. -
Attach both pads to the area of the body that you wish to treat. Make sure the pads do not touch each other.
-
After using the pads, stick the transparent film onto the self-adhesive gel layer again.
DR-HO’S NECK PAIN PRO
PAD PLACEMENT CHART
Fast relief for headaches & pain related to sore achy muscles in neck & shoulders.
Disclaimer:
DR-HO’S Neck Pain Pro is not designed to diagnose, treat or cure any disease. If you experience any pain or suffer from any health conditions you should consult your doctor for proper diagnosis and treatment.
Precautions:
Do NOT use DR-HO’S or any other electronic stimulators if you wear a pacemaker or if you are pregnant, due to unknown safety issues. If you have any questions or concerns, please consult your doctor before use.
Less pain and tension means more activities and fun in your life! Dr. Michael
Ho
www.drhonow.eu
V2023-04 | Model P.T.S.-IIB, Neck Therapy Pro-IV Made in China
Guang Zhou Xinbo Electronic Co Ltd. 23 Building, The Second Phase,
HuachuangAnimation Industry Park, Panyu, Guangzhou, Guangdong Province, 511450
P.R. China
MedNet EC-REP GmbH Borkstrasse 10, 48163 Münster, Germany
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>